240V Surge Protection Device KYSPD-20T2+3-3P+1N | Kuangya

  • 240V surge protection device avec 3+1 topology (L1-L2-L3-N) for 230/400 V AC networks.

  • Surtensions : En 10 kA (8/20 µs), Imax 20 kA (8/20 µs), Jusqu'à ≤ 0,3-1,8 kV en fonction de Uc.

  • Combines MOV + GDT technology for L–N and N–PE coordinated protection, pluggable modules, optional Contacts de signalisation RC.

Obtenir un devis

Catégorie :
The Kuangya KYSPD-20T2+3-3+1 is a 240V surge protection device designed for three-phase + neutral systems at 230/400 V AC. It uses a 3+1 topology, with MOV protection for L–N and coordinated GDT+MOV protection for N–PE, offering reliable suppression of transient overvoltages from lightning and switching surges.Its compact pluggable cartridge design allows easy replacement, while integrated thermal disconnectors ensure safe operation. Visual green/red indicators provide status feedback, and optional RC contacts enable remote fault monitoring.

Caractéristiques principales

  • Class II+III / Type 2+3 surge protection device with 3+1 topology.
  • Courant de décharge nominal (In) : 10 kA (8/20 μs).
  • Courant de décharge maximal (Imax) : 20 kA (8/20 μs).
  • Niveau de protection contre la tension (Up) : ≤ 0,3-1,8 kV selon Uc (75-440 V).
  • Response time: < 25 ns (L–N), < 100 ns (N–PE).
  • Fusible de secours : max 63 A gL/gG ; ISCCR 10 kA AC.
  • Pluggable module, thermal disconnector, green/red fault status indicator.
  • Optional RC remote signaling contacts for BMS/PLC integration.
  • Boîtier IP20, thermoplastique UL94 V-0 ; température de fonctionnement -40 °C à +70 °C.
  • Montage sur rail DIN (35 mm, EN 60715) ; conforme à la norme IEC/EN 61643-11.

Spécifications

Code produitKYSPD-20T2+3-3+1
Catégorie240V surge protection device
Tension nominale du système230/400 V AC
Topologie3+1 (L-N MOV, N-PE GDT+MOV)
Tension de fonctionnement continu (Uc)75 / 150 / 275 / 320 / 385 / 440 V
Courant de décharge nominal (In, 8/20 μs)10 kA
Courant de décharge maximal (Imax, 8/20 μs)20 kA
Niveau de protection de la tension (vers le haut)≤ 0,3-1,8 kV
Temps de réponse< 25 ns (L–N), < 100 ns (N–PE)
Fusible de secours (max)63 A gL/gG
Courant nominal de court-circuit (ISCCR)10 kA AC
Température de fonctionnement-40 °C à +70 °C
MontageRail DIN 35 mm, EN 60715
Enceinte / ProtectionThermoplastique UL94 V-0 / IP20
Signalisation à distance (RC)En option ; AC 250 V / 0,5 A ; DC 250 V / 0,1 A ; 125 V / 0,2 A ; 75 V / 0,5 A
NormesIEC/EN 61643-11

Câblage et dimensions

Connection diagram 240V surge protection device KYSPD-20T2+3-3+1

Connection diagram 240V surge protection device KYSPD-20T2+3-3+1

Dimensions 240V surge protection device KYSPD-20T2+3-3+1

Dimensions 240V surge protection device KYSPD-20T2+3-3+1

Applications

  • Main distribution boards in residential and commercial buildings (240V systems).
  • Protection of elevators, industrial control systems, and sensitive electronics.
  • Panels requiring coordinated 3+1 surge protection in TT/TN-S networks.

FAQ

  • What topology does KYSPD-20T2+3-3+1 use? It uses 3+1 topology: L–N MOV, N–PE GDT+MOV.
  • What is its surge discharge capacity? In 10 kA, Imax 20 kA.
  • Where is it applied? In 230/400 V AC three-phase + N systems, especially 240V distribution panels.
  • Prend-il en charge le suivi ? Yes, optional RC contacts provide remote signaling.
  • What is the maximum back-up fuse rating? 63 A gL/gG.