Fusibles 1000v dc | KYPV-H3 gPV Fuse Link (Square-Body, 315-500A)

  • Square-body Fusibles 1000v dc (gPV), H3 frame, 315–500A current range.

  • High breaking capacity 50 kA DC; ceramic body, silver fuse element, quartz-sand arc quenching.

  • Conforme à IEC 60269-6 / UL 248-19; fits KYPV-H3B fuse holder.

Obtenir un devis

Catégorie :

Vue d'ensemble

Le KYPV-H3 is a square-body 1000v dc fuse designed for high-current
PV combiner box mains, ESS DC busbars, and inverter input circuits. With a current range of
315–500A, this gPV fuse link offers safe interruption of DC overloads and short circuits.
Constructed with a ceramic body, silver fuse element, and quartz-sand filling, it achieves a
breaking capacity up to 50 kA. Use with the
KYPV-H3B fuse holder for secure installation.

Caractéristiques principales

  • Square-body gPV fuse linktaille de cadre H3.
  • Focus on long-tail: Fusibles 1000v dc (range 315–500A).
  • Rated voltage: 1000 V DC, breaking capacity: 50 kA.
  • High-reliability design: ceramic body, silver element, quartz-sand arc quenching.
  • Standards compliance:
    IEC 60269-6,
    UL 248-19.
  • Compatible holder: KYPV-H3B.

Spécifications

TypegPV fuse link, square-body H3
Tension nominale1000 V DC
Gamme actuelle315–500 A
Capacité de rupture50 kA (DC)
La constructionCeramic body, silver fuse element, quartz-sand filling
NormesIEC 60269-6 ; UL 248-19 ; GB/T 13539-6
Compatible HolderKYPV-H3B
ApplicationsHigh-current PV combiner boxes, ESS busbars, inverter DC inputs

Dimensions

1000v dc fuses dimension

Applications

  • Main fuse in utility-scale PV combiner boxes (1000 V DC).
  • Energy storage system DC bus coupling.
  • Inverter and DC/DC converter input protection.
  • Industrial DC distribution up to 1000 V DC, 500 A.

FAQ

Q1. What is the current range of KYPV-H3?

It covers 315–500 A at 1000 V DC.

Q2. What holder is compatible with KYPV-H3?

Le KYPV-H3B fuse holder (square-body base) is recommended.

Q3. What standards does KYPV-H3 comply with?

IEC 60269-6 and UL 248-19, suitable for PV and ESS DC circuits.

Q4. What is the DC breaking capacity?

It is rated at 50 kA for DC faults.

Demande de devis

Need high-current Fusibles 1000v dc (KYPV-H3, 315–500A) for your PV or ESS system?
Contactez nous for engineering support and pricing.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “1000v dc fuses | KYPV-H3 gPV Fuse Link (Square-Body, 315–500A)”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *