rccb 2 pole for reliable earth-leakage protection in single-phase and three-phase boards (2P/4P range)
In: 16–100A; IΔn: 10/30/100/300 mA; Ue: 240 V (2P) / 415 V (4P); Inc=IΔc up to 10 kA; Uimp 6 kV
AC / A / ASi options; IEC/EN 61008-1 with NF, ISI, UKCA, CE approvals
The Kuangya VFL002 is an rccb 2 pole (also available as 4 pole) residual current device engineered to
protect people and installations from electric shock and fire risk due to earth-leakage faults. It offers AC, A, and
high-immunity ASi detection classes, making it suitable for residential housing, commercial buildings, and light
industrial facilities. Selection covers rated currents from 16 A to 100 A and sensitivities from 10 mA to 300 mA.
| Estándar | IEC/EN 61008-1 |
|---|---|
| Modelo | VFL002 |
| Postes | 2P, 4P |
| Corriente nominal (In) | 16A, 25A, 32A, 40A, 63A, 80A, 100A |
| Rated sensitivity (IΔn) | 10 mA (16–40 A), 30 mA, 100 mA, 300 mA |
| Tensión nominal (Ue) | 2P: 240 V~; 4P: 415 V~ |
| Insulation voltage (Ui) | 500 V |
| Rated frequency | 50/60 Hz |
| Rated residual making & breaking (IΔm) | 500 A (In = 16–40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A) |
| Conditional short-circuit (Inc = IΔc) | 6000 A, 10000 A |
| Waveform sensitivity | AC, A, ASi |
| Tripping time classes | Instantaneous / Short time delay (10–300 ms) / Selective S (150–500 ms) |
| Break time under IΔn (Normal) | ≤ 100 ms |
| Impulse withstand (Uimp) | 6 kV |
| Dielectric test voltage | 2.5 kV (1 min at power frequency) |
| Pollution degree | 2 |
| Electrical life | ≥ 2000 operations |
| Mechanical life | ≥ 2000 operations |
| Fault current indicator | Yes |
| Terminal protection degree | IP20 |
| Ambient temperature (avg ≤ 35 °C) | −25 °C to +55 °C |
| Storage temperature | −40 °C to +70 °C |
| Terminal connection | Cable / Barra colectora con pasador |
| Terminal size (cable, top/bottom) | 25–35 mm²; 18–3 / 18–2 AWG (per size class) |
| Terminal size (busbar, top/bottom) | 10/16 mm²; 18–8 / 18–5 AWG |
| Tightening torque | 2.5 N·m (≈ 22 in-lbs) |
| Montaje | DIN rail EN 60715 (35 mm), fast clip |
| Connection | From top and bottom |
| Approvals | NF, ISI, UKCA, CE |
Conforme a IEC/EN 61008-1; certified NF, ISI, UKCA, CE.
Use 2P for single-phase 240 V~ systems and 4P for three-phase 415 V~ systems.
10/30 mA for additional personal protection; 100/300 mA for fire protection and selectivity.
Use an upstream breaker/fuse so the installation respects Inc = IΔc (6 kA / 10 kA) under fault conditions.