240v Surge Protection Device KYSPD-40T2-3P | Kuangya

  • Dispositivo de protección contra sobretensiones de 240 V for three-phase 3P (L1-L2-L3) AC networks, suitable for TN-S, TN-C, and TT systems.

  • Rated discharge current In 20 kA (8/20 µs), maximum discharge Imax 40 kA (8/20 µs), voltage protection level Hasta ≤ 1,3-2,0 kV en función de Uc.

  • Pluggable cartridge with thermal disconnector, visual fault indicator, optional RC contacts, DIN-rail mounting.

Solicitar presupuesto

Categoría:
The Kuangya KYSPD-40T2-3P is a Dispositivo de protección contra sobretensiones de 240 V
designed for three-phase systems (L1, L2, L3). It provides Type 2
protection against transient overvoltages caused by indirect lightning
and switching operations in 230/400 V AC TN-S, TN-C, and TT networks.Equipped with high-capacity MOV elements, the device ensures reliable
surge suppression with a pluggable module structure for easy service.
Integrated thermal disconnectors and clear fault indicators guarantee safety,
while optional RC contacts enable monitoring integration with building
management systems (BMS) or PLC.

Características principales

  • Class II / Type 2 surge protection for 240 V three-phase systems.
  • Corriente nominal de descarga (In): 20 kA (8/20 μs).
  • Corriente máxima de descarga (Imax): 40 kA (8/20 μs).
  • Voltage protection level (Up): ≤ 1.3–2.0 kV depending on Uc (230–385 V).
  • Response time < 25 ns, ensuring rapid surge suppression.
  • Back-up fuse: max 125 A gL/gG; ISCCR up to 25 kA AC.
  • Pluggable module with thermal disconnector and visible green/red status.
  • Optional RC remote signaling contacts: AC 250 V / 0.5 A; DC 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A.
  • Housing IP20, thermoplastic UL94 V-0; operating temperature -40 °C to +80 °C.
  • Mounting: 35 mm DIN rail (EN 60715); complies with IEC/EN 61643-11.

Especificaciones

Código del productoKYSPD-40T2-3P
CategoríaDispositivo de protección contra sobretensiones de 240 V
Tensión nominal del sistema230/400 V CA
Postes3P (L1, L2, L3)
Tensión de funcionamiento continuo (Uc)230 V / 320 V / 385 V
Corriente nominal de descarga (In, 8/20 μs)20 kA
Corriente de descarga máxima (Imax, 8/20 μs)40 kA
Nivel de protección de tensión (arriba)≤ 1,3-2,0 kV
Tiempo de respuesta< 25 ns
Fusible de reserva (máx.)125 A gL/gG
Corriente nominal de cortocircuito (ISCCR)25 kA CA
Temperatura de funcionamiento-40 °C a +80 °C
MontajeCarril DIN de 35 mm, EN 60715
Cerramiento / ProtecciónTermoplástico UL94 V-0 / IP20
Señalización remota (RC)Opcional; CA 250 V / 0,5 A; CC 250 V / 0,1 A; 125 V / 0,2 A; 75 V / 0,5 A
NormasCEI/EN 61643-11

Cableado y dimensiones

Connection diagram 240v surge protection device KYSPD-40T2-3P

Connection diagram 240v surge protection device KYSPD-40T2-3P

Dimensions 240v surge protection device KYSPD-40T2-3P

Dimensions 240v surge protection device KYSPD-40T2-3P

Aplicaciones

  • Three-phase 240 V AC distribution boards in residential, commercial, and industrial facilities.
  • Coordination with upstream Type 1 arresters in TT and TN systems.
  • Electrical panels requiring reliable 3P surge protection with monitoring options.

PREGUNTAS FRECUENTES

  • What class of SPD is KYSPD-40T2-3P? It is Class II, Type 2 according to IEC/EN 61643-11.
  • What is its discharge capacity? In 20 kA, Imax 40 kA per phase.
  • Can it be used in 240 V three-phase systems? Yes, it is designed for L1-L2-L3 protection in 230/400 V AC networks.
  • Does it provide remote signaling? Sí, hay disponibles contactos RC opcionales.
  • What is the maximum backup fuse rating? 125 A gL/gG.
Para precios detallados y asistencia técnica, por favor Contacto.Explore more Kuangya products: DC SPD, Protección contra sobretensiones de CA.

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “240v Surge Protection Device KYSPD-40T2-3P | Kuangya”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *