Dispositivo de protección contra sobretensiones de CC KY-40/G600 (Tipo 2, 600 V)

  • En 600v cc spd KY-40/G600 provides Type 2 surge protection for photovoltaic DC systems.
  • Compact DIN-rail design with status indication and optional alarm contacts, compliant with IEC 61643-31.
  • Suitable for PV combiner boxes and inverter DC terminals, with shared T2 wiring/dimension diagrams.
Solicitar presupuesto

Categoría:

Visión general

En 600v cc spd KY-40/G600 is a Type 2 DC surge protective device diseñado para
Cajas de conexiones fotovoltaicas, string inputs, and inverter DC terminals up to 600VDC.
It limits residual overvoltage caused by indirect lightning and switching surges, protecting PV equipment and cables.
Totalmente conforme con IEC 61643-31, CE, UKCA, and RoHS certifications.

Características principales

Especificaciones

TipoTipo 2 (T2)
Tensión del sistema (Ucpv)600 V CC
Corriente nominal de descarga (In)20 kA
Corriente máxima de descarga (Imax)40 kA
Nivel de protección de tensión (Up)≤ 3.0 kV
Tiempo de respuesta (ta)< 25 ns
Resistencia a cortocircuitos fotovoltaicos (Iscpv)20 kA
Modo de protección / TopologíaTipo U
Contacto de alarma (opcional)220V, 0,5A, NO/NC
Fusible aguas arriba recomendadoLS7-50k (según hoja de datos)
Cableado / TerminalesTerminales de tornillo de 6-35 mm².
MontajeCarril DIN de 35 mm
Envolvente / InflamabilidadCarcasa de plástico, UL94-V0
Condiciones de funcionamiento-40℃ ~ +70℃; ≤95% RH
Dimensiones (An×Al×F)36 × 83 × 67 mm
Normas y conformidadIEC 61643-31:2018, GB/T 18802.31, CE, UKCA, RoHS

Cableado y dimensiones

Wiring diagram of 600v dc spd KY-40/G600 Type 2 surge protective device for solar photovoltaic systems
Esquema eléctrico compartido para la serie KY T2 (600V/1000V/1500V/2000V).
Dimension drawing of 600v dc spd KY-40/G600 Type 2 surge protective device for PV combiner box protection
Plano de dimensiones compartido para la serie KY T2.

Aplicaciones

  • PV combiner boxes and inverter DC terminals operating at 600VDC.
  • Residential and small commercial rooftops requiring Type 2 surge protection.
  • Coordination with upstream fuses and disconnectors in distributed PV systems.

FAQs

Q1. When should I use a 600v cc spd Type 2 device in PV systems?

Use KY-40/G600 at PV string or inverter inputs to limit residual surge voltage from indirect lightning and switching events.

Q2. Can KY-40/G600 be installed inside a PV combiner box?

Yes. It is designed for PV combiner boxes and inverter DC terminals at 600VDC; follow the wiring diagram and datasheet terminals.

Q3. Does KY-40/G600 support remote alarm indication?

Yes. Alarm terminals (NO/NC) are reserved as per the datasheet, rated 220V 0.5A.

Q4. Which standards apply to KY-40/G600?

Se cubren las certificaciones IEC 61643-31, GB/T 18802.31, CE, UKCA y RoHS.

Request a Quote for 600v dc spd KY-40/G600

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “KY-40/G600 DC Surge Protective Device (Type 2, 600V)”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *