RCCB VKL11F - Interruptor diferencial residual

  • Kuangya VKL11F tipo f rccb for mixed-frequency residual-current protection in single- and three-phase systems

  • 2P/4P, In 16–100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Ui 500 V; 50/60 Hz

  • Uimp 4/6 kV; Inc = IΔc 6/10 kA (with upstream SCPD); IP20 terminals; DIN-rail EN 60715

Solicitar presupuesto

Categoría:

Visión general

The VKL11F tipo f rccb detects earth leakage including mixed-frequency components that commonly
occur with inverters, VFD-driven motors, and UPS equipment. It disconnects the circuit when residual current
exceeds the set threshold to protect people and installations against electric shock and fire hazards.
Available as 2P (single-phase) and 4P (three-phase).

Características principales

  • Postes: 2P / 4P
  • Corriente nominal (In): 16, 25, 32, 40, 63, 80, 100 A
  • Sensibilidad nominal (IΔn): 10 / 30 / 100 / 300 mA
  • Tensión nominal (Ue): 240 V~ (2P) / 415 V~ (4P)
  • Tensión de aislamiento (Ui): 500 V   |   Frequency: 50/60 Hz
  • Fabricación y rotura residual (IΔm): 500 / 630 / 800 / 1000 A (per In group)
  • Conditional short-circuit current: Inc = IΔc 6 kA / 10 kA (with upstream SCPD)
  • Resistencia al impulso (Uimp): 4 kV / 6 kV
  • Dielectric test voltage: 2.5 kV for 1 min (power frequency)
  • Tripping behavior: Instantaneous; Short time delay (10–300 ms); Selective S (150–500 ms)
  • Break time under IΔn (Normal): ≤ 100 ms
  • Terminal protection degree: IP20
  • Endurance: ≥ 20,000 mechanical / ≥ 2,000 electrical operations
  • Mounting: DIN rail EN 60715 (35 mm), fast clip

Datos técnicos

ModeloVKL11F
EstándarIEC/EN 61008-1
Postes2P, 4P
Corriente nominal (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilidad nominal (IΔn)10 mA, 30 mA, 100 mA, 300 mA
Tensión nominal (Ue)2P: 240 V~; 4P: 415 V~
Tensión de aislamiento (Ui)500 V
Frecuencia nominal50/60 Hz
Fabricación y rotura de residuos (IΔm)500 A (In 16–40 A); 630 A (In 63 A); 800 A (In 80 A); 1000 A (In 100 A)
Conditional short-circuit current (Inc = IΔc)6000 A, 10000 A (with upstream SCPD)
Resistencia al impulso (Uimp)4 kV / 6 kV
Dielectric test voltage2.5 kV, 1 min
Tripping classesInstantaneous / Short time delay (10–300 ms) / Selective S (150–500 ms)
Break time under IΔn≤ 100 ms (Normal type)
Pollution degree2
Electrical life≥ 2000 operations
Mechanical life≥ 20000 operations
Grado de protección de los terminalesIP20
Temperatura ambiente−25 °C to +55 °C (daily average ≤ 35 °C)
Temperatura de almacenamiento-40 °C a +70 °C
Conexión de terminalesCable / Barra colectora con pasador
Tamaño del terminal (cable)25–35 mm²; 18–3 / 18–2 AWG
Tamaño del terminal (barra colectora)10/16 mm²; 18–8 / 18–5 AWG
Par de apriete2.5 N·m (≈ 22 in-lbs)
MontajeCarril DIN EN 60715 (35 mm)
ConexiónArriba y abajo
Waveform classType F (mixed-frequency residual currents)

Aplicaciones

  • Inverter/UPS outputs, VFD-driven motors, appliances with mixed-frequency leakage
  • Residential, commercial, and light-industrial panels requiring tipo f rccb protection
  • Installations coordinated with upstream SCPD for 6/10 kA conditional ratings

type f rccb VKL11F Kuangya 2P/4P 16–100A 10/30/100/300 mA

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “RCCB VKL11F — Residual Current Circuit Breaker”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *