VKL003 / VKL003N RCBO - Unipolar + Neutro (1P+N) 5-40A

  • rcbo single pole (1P+N) RCBO for residential & commercial branches, In 5–40A, curves B/C.

  • Tipo AC / Tipo A, sensitivities IΔn 6 / 10 / 30 / 100 / 300 mA; Icn up to 10 kA @ 240 V (VKL003) / 15 kA @ 120 V (VKL003N).

  • SEMKO / UKCA / CE / SAA certified; electrical & mechanical endurance 2,000 cycles; DIN-rail mounting with front test button.

Solicitar presupuesto

Categoría:

rcbo unipolar VKL003 / VKL003N is a compact 1P+N residual-current circuit breaker with overcurrent protection, rated 5–40 A with Type AC/A, multiple sensitivities, and B/C curves for residential and commercial distribution circuits.

Visión general

VKL003 and VKL003N provide combined protection against overload, short circuit, and
residual current faults on single-phase branches. Both share the same 1P+N form factor
and current range (5–40 A). VKL003 targets 240 V systems with breaking capacity
up to 10 kA, while VKL003N is optimized for 120 V systems with
15 kA Icn. Type AC and Type A options plus five sensitivity levels enable precise
coordination across lighting and socket circuits.

Características principales

  • Form factor: 1P+N (single-pole + neutral), compact modular width
  • Corriente nominal (In): 5–40 A (typical steps: 5/6/10/16/20/25/32/40 A)
  • Tipo de corriente residual: Tipo AC / Tipo A
  • Sensitivities (IΔn): 6 / 10 / 30 / 100 / 300 mA
  • Tripping curves: B (3–5×In), C (5–10×In)
  • Capacidad de rotura (Icn): VKL003 4.5/6/10 kA @ 240 V; VKL003N 15 kA @ 120 V
  • Frequency: 50/60 Hz; front test button (T) for routine verification
  • Service life: electrical 2,000 cycles / mechanical 2,000 cycles
  • Mounting: DIN-rail; front wiring; compact installation depth

RCBO Single Pole Technical Data — VKL003 / VKL003N

ParámetroVKL003VKL003N
Postes1P+N (single-pole + neutral)
Corriente nominal (In)5–40 A5–40 A
Tensión nominal (Ue)AC 240 VAC 120 V
Frecuencia50/60 Hz
Tipo de corriente residualTipo AC / Tipo A
Corriente residual nominal (IΔn)6 / 10 / 30 / 100 / 300 mA
Tripping characteristic (MCB curve)B: 3–5 × In; C: 5–10 × In
Capacidad de rotura (Icn)4.5 / 6 / 10 kA @ 240 V15 kA @ 120 V
ResistenciaElectrical 2,000 cycles; Mechanical 2,000 cycles
InstalaciónCarril DIN; cableado frontal; botón de prueba (T)
Recommended applicationsResidential & commercial lighting and socket branches
CertificacionesSEMKO, UKCA, CE, SAA
NormasIEC/EN 61009-1

Aplicaciones

  • Apartments & houses: lighting and socket circuits up to 40 A
  • Commercial offices & retail: small-load branch protection
  • Public buildings: admin rooms, classrooms, auxiliary circuits
 

Normas y conformidad

Conforms to IEC/EN 61009-1. Certified by SEMKO, UKCA, CE, SAA.
Coordinate with upstream protection and follow local codes for selectivity and fault levels.

PREGUNTAS FRECUENTES

What is the difference between VKL003 and VKL003N?

Both are 1P+N, 5–40 A with Type AC/A and five IΔn levels. VKL003 is for 240 V (up to 10 kA Icn); VKL003N is for 120 V (15 kA Icn).

When should I choose curve B or curve C?

Use curve B (3–5×In) for resistive/lightly inductive loads; use curve C (5–10×In) for circuits with higher inrush such as motors or transformers.

What is the advantage of an rcbo single pole form factor?

The compact 1P+N layout saves rail width while providing full residual and overcurrent protection—ideal for lighting and socket branches.

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “VKL003 / VKL003N RCBO — Single-Pole + Neutral (1P+N) 5–40A”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *