Typ 1 Überspannungsschutzgerät KYSPD-25T1-1P | Kuangya

  • Class I / Type 1 SPD for service entrance, 230/400 V AC systems.

  • Impulse current Iimp 25 kA (10/350 μs), In 25 kA, Imax 100 kA.

  • Pluggable module with visual indicator, DIN-rail, optional remote signaling (RC).

Angebot einholen

Kategorie:
Die Überspannungsschutzgerät Typ 1 KYSPD-25T1-1P is designed for main distribution boards and service entrances. It protects low-voltage AC installations against direct lightning currents and high-energy surges per IEC/EN 61643-11. With an impulse discharge current rating of 25 kA per pole (10/350 μs), it provides robust first-stage protection in coordinated systems.

Wesentliche Merkmale

  • Entspricht der IEC/EN 61643-11, Klasse I / Typ 1.
  • Impulse discharge current Iimp: 25 kA (10/350 μs); In 25 kA; Imax 100 kA.
  • Uc options: 320 V, 385 V, 440 V AC; nominal system Uo/Un 230/400 V AC.
  • Pluggable cartridge with thermal disconnector and green/red status window.
  • Optional RC terminals for remote status signaling.
  • Housing UL94 V-0, IP20 (built-in); 35 mm DIN rail mounting.
  • Suitable for TN-S / TN-C / TT systems (correct L-N / N-PE wiring).
  • Ideal as a Überspannungsschutzgerät Typ 1 at the service entrance in coordinated SPD schemes.

Spezifikationen

ParameterWert
Produkt-CodeKYSPD-25T1-1P
KategorieType 1 / Class I SPD
Nennspannung des Systems (Uo/Un)230 / 400 V AC
Max. Kontinuierliche Betriebsspannung (Uc)320 / 385 / 440 V WECHSELSTROM
Nenn-Entladestrom (In, 8/20 μs)25 kA
Max. Entladestrom (Imax, 8/20 μs)100 kA
Impuls-Entladestrom (Iimp, 10/350 μs)25 kA pro Pol
Spannungsschutzstufe (Up)~1.6–2.0 kV (by variant)
Reaktionszeit< 25 ns
Follow Current Interrupt Rating100 A RMS
Kurzschlussstrom-Bewertung (ISCCR)50 kA
Vorsicherung (max)315 A gL/gG
Betriebstemperatur-40 °C ... +70 °C
Montage35 mm DIN-Schiene (EN 60715)
GehegeThermoplastischer Kunststoff, UL94 V-0
SchutzgradIP20 (eingebaut)
FernsignalisierungOptionale RC-Kontakte
NormenIEC 61643-11 / EN 61643-11

Verdrahtung & Abmessungen

  • Anschlussplan: kyspd-25t1-connection
  • SPD-T1-1P-wiring-diagram
  • Abmessungen: kyspd-25t1-dimensions
  • SPD-T1-1P-Dimension

Anwendungen

  • Service entrance / main distribution (LPZ 0→1) — first stage Überspannungsschutzgerät Typ 1.
  • Industrial & commercial buildings with high lightning exposure.
  • Upstream in coordinated protection with downstream Type 2 / Type 3 SPDs.

FAQ

Where should this SPD be installed?

At the service entrance or main distribution board, as the first protection stage.

Does it support TT and TN systems?

Yes, with proper wiring modes L-N and N-PE.

What backup fuse is required?

Maximum 315 A gL/gG, as recommended in technical data.

Can it be replaced easily?

Yes, the cartridge is pluggable and field-replaceable.

Is remote monitoring available?

Yes, RC contacts are optional for status signaling.

What is the ISCCR rating?

50 kA short-circuit withstand capacity.

What happens if the module fails?

The thermal disconnector isolates it and the indicator turns red.

Welche Normen erfüllt sie?

IEC/EN 61643-11 für Überspannungsschutzgeräte.

Angebot einholen - Verwandt: AC MCB, Manueller Umschalter

Rezensionen

Es gibt noch keine Rezensionen.

Schreibe die erste Rezension für „Type 1 Surge Protection Device KYSPD-25T1-1P | Kuangya“

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert