{"id":1283,"date":"2025-09-09T09:17:28","date_gmt":"2025-09-09T09:17:28","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1283"},"modified":"2025-12-01T06:36:34","modified_gmt":"2025-12-01T06:36:34","slug":"type-1-surge-protection-device","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ru\/product\/type-1-surge-protection-device\/","title":{"rendered":"\u0423\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u044b\u0445 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0439 \u0442\u0438\u043f 1 KYSPD-25T1-1P | Kuangya"},"content":{"rendered":"<section id=\"overview\">\u0421\u0430\u0439\u0442 <strong>\u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0442\u0438\u043f\u0430 1<\/strong> KYSPD-25T1-1P is designed for main distribution boards and service entrances. It protects low-voltage AC installations against direct lightning currents and high-energy surges per IEC\/EN 61643-11. With an impulse discharge current rating of 25 kA per pole (10\/350 \u03bcs), it provides robust first-stage protection in coordinated systems.<\/section>\n<section id=\"features\">\n<h3>\u041e\u0441\u043d\u043e\u0432\u043d\u044b\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h3>\n<ul>\n<li>\u0421\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 IEC\/EN 61643-11, \u043a\u043b\u0430\u0441\u0441 I \/ \u0442\u0438\u043f 1.<\/li>\n<li>Impulse discharge current Iimp: <strong>25 kA (10\/350 \u03bcs)<\/strong>; In 25 kA; Imax 100 kA.<\/li>\n<li>Uc options: 320 V, 385 V, 440 V AC; nominal system Uo\/Un 230\/400 V AC.<\/li>\n<li>Pluggable cartridge with thermal disconnector and green\/red status window.<\/li>\n<li>Optional RC terminals for remote status signaling.<\/li>\n<li>Housing UL94 V-0, IP20 (built-in); 35 mm DIN rail mounting.<\/li>\n<li>Suitable for TN-S \/ TN-C \/ TT systems (correct L-N \/ N-PE wiring).<\/li>\n<li>Ideal as a <strong>\u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0442\u0438\u043f\u0430 1<\/strong> at the service entrance in coordinated SPD schemes.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0417\u043d\u0430\u0447\u0435\u043d\u0438\u0435<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041a\u043e\u0434 \u0442\u043e\u0432\u0430\u0440\u0430<\/td>\n<td>KYSPD-25T1-1P<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u0430\u0442\u0435\u0433\u043e\u0440\u0438\u044f<\/td>\n<td>\u0422\u0438\u043f 1 \/ \u041a\u043b\u0430\u0441\u0441 I SPD<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b (Uo\/Un)<\/td>\n<td>230 \/ 400 \u0412 \u041f\u0415\u0420\u0415\u041c\u0415\u041d\u041d\u041e\u0413\u041e \u0422\u041e\u041a\u0410<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0430\u043a\u0441. \u041d\u0435\u043f\u0440\u0435\u0440\u044b\u0432\u043d\u043e\u0435 \u0440\u0430\u0431\u043e\u0447\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 (Uc)<\/td>\n<td>320 \/ 385 \/ 440 \u0412 \u041f\u0415\u0420\u0415\u041c\u0415\u041d\u041d\u041e\u0413\u041e \u0422\u041e\u041a\u0410<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u0440\u0430\u0437\u0440\u044f\u0434\u0430 (\u0412, 8\/20 \u043c\u043a\u0441)<\/td>\n<td>25 \u043a\u0410<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0430\u043a\u0441. \u0422\u043e\u043a \u0440\u0430\u0437\u0440\u044f\u0434\u0430 (Imax, 8\/20 \u043c\u043a\u0441)<\/td>\n<td>100 \u043a\u0410<\/td>\n<\/tr>\n<tr>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u044b\u0439 \u0442\u043e\u043a \u0440\u0430\u0437\u0440\u044f\u0434\u0430 (Iimp, 10\/350 \u043c\u043a\u0441)<\/td>\n<td>25 \u043a\u0410 \u043d\u0430 \u043f\u043e\u043b\u044e\u0441<\/td>\n<\/tr>\n<tr>\n<td>\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b \u043f\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044e (\u0432\u0432\u0435\u0440\u0445)<\/td>\n<td>~1.6\u20132.0 kV (by variant)<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u043b\u0438\u043a\u0430<\/td>\n<td>&lt; 25 \u043d\u0441<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043f\u0440\u0435\u0440\u044b\u0432\u0430\u043d\u0438\u044f<\/td>\n<td>100 A RMS<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a \u043a\u043e\u0440\u043e\u0442\u043a\u043e\u0433\u043e \u0437\u0430\u043c\u044b\u043a\u0430\u043d\u0438\u044f (ISCCR)<\/td>\n<td>50 \u043a\u0410<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0435\u0437\u0435\u0440\u0432\u043d\u044b\u0439 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c (\u043c\u0430\u043a\u0441.)<\/td>\n<td>315 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0431\u043e\u0447\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430<\/td>\n<td>-40 \u00b0C ... +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u043d\u0442\u0430\u0436<\/td>\n<td>35 \u043c\u043c DIN-\u0440\u0435\u0439\u043a\u0430 (EN 60715)<\/td>\n<\/tr>\n<tr>\n<td>\u0428\u043a\u0430\u0444<\/td>\n<td>\u0422\u0435\u0440\u043c\u043e\u043f\u043b\u0430\u0441\u0442\u0438\u043a, UL94 V-0<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b<\/td>\n<td>IP20 (\u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u044b\u0439)<\/td>\n<\/tr>\n<tr>\n<td>\u0423\u0434\u0430\u043b\u0435\u043d\u043d\u0430\u044f \u0441\u0438\u0433\u043d\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u044f<\/td>\n<td>\u0414\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 RC-\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b<\/td>\n<td>IEC 61643-11 \/ EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u041f\u0440\u043e\u0432\u043e\u0434\u043a\u0430 \u0438 \u0440\u0430\u0437\u043c\u0435\u0440\u044b<\/h3>\n<ul>\n<li>\u0421\u0445\u0435\u043c\u0430 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f: <em>kyspd-25t1-connection<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1284\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-wiring-diagram-300x276.png\" alt=\"SPD-T1-1P-wiring-diagram\" width=\"507\" height=\"466\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-wiring-diagram-300x276.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-wiring-diagram.png 533w\" sizes=\"auto, (max-width: 507px) 100vw, 507px\" \/><\/li>\n<li>\u0420\u0430\u0437\u043c\u0435\u0440\u044b: <em>kyspd-25t1-dimensions<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1285\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-Dimension-300x280.png\" alt=\"SPD-T1-1P-Dimension\" width=\"517\" height=\"482\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-Dimension-300x280.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-Dimension.png 369w\" sizes=\"auto, (max-width: 517px) 100vw, 517px\" \/><\/li>\n<\/ul>\n<\/section>\n<section id=\"apps\">\n<h3>\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h3>\n<ul>\n<li>Service entrance \/ main distribution (LPZ 0\u21921) \u2014 first stage <strong>\u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u043e \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f \u0442\u0438\u043f\u0430 1<\/strong>.<\/li>\n<li>Industrial &amp; commercial buildings with high lightning exposure.<\/li>\n<li>Upstream in coordinated protection with downstream Type 2 \/ Type 3 SPDs.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0427\u0410\u0421\u0422\u041e \u0417\u0410\u0414\u0410\u0412\u0410\u0415\u041c\u042b\u0415 \u0412\u041e\u041f\u0420\u041e\u0421\u042b<\/h3>\n<details>\n<summary>Where should this SPD be installed?<\/summary>\n<p>At the service entrance or main distribution board, as the first protection stage.<\/p>\n<\/details>\n<details>\n<summary>Does it support TT and TN systems?<\/summary>\n<p>Yes, with proper wiring modes L-N and N-PE.<\/p>\n<\/details>\n<details>\n<summary>\u041a\u0430\u043a\u043e\u0439 \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u044b\u0439 \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044c \u0442\u0440\u0435\u0431\u0443\u0435\u0442\u0441\u044f?<\/summary>\n<p>Maximum 315 A gL\/gG, as recommended in technical data.<\/p>\n<\/details>\n<details>\n<summary>Can it be replaced easily?<\/summary>\n<p>Yes, the cartridge is pluggable and field-replaceable.<\/p>\n<\/details>\n<details>\n<summary>\u0414\u043e\u0441\u0442\u0443\u043f\u0435\u043d \u043b\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u044b\u0439 \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433?<\/summary>\n<p>Yes, RC contacts are optional for status signaling.<\/p>\n<\/details>\n<details>\n<summary>\u0427\u0442\u043e \u0442\u0430\u043a\u043e\u0435 \u0440\u0435\u0439\u0442\u0438\u043d\u0433 ISCCR?<\/summary>\n<p>50 kA short-circuit withstand capacity.<\/p>\n<\/details>\n<details>\n<summary>\u0427\u0442\u043e \u043f\u0440\u043e\u0438\u0437\u043e\u0439\u0434\u0435\u0442, \u0435\u0441\u043b\u0438 \u043c\u043e\u0434\u0443\u043b\u044c \u0432\u044b\u0439\u0434\u0435\u0442 \u0438\u0437 \u0441\u0442\u0440\u043e\u044f?<\/summary>\n<p>The thermal disconnector isolates it and the indicator turns red.<\/p>\n<\/details>\n<details>\n<summary>\u041a\u0430\u043a\u0438\u043c \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0430\u043c \u043e\u043d\u0430 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0443\u0435\u0442?<\/summary>\n<p>IEC\/EN 61643-11 \u0434\u043b\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u0437\u0430\u0449\u0438\u0442\u044b \u043e\u0442 \u043f\u0435\u0440\u0435\u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta\"><a href=\"\/ru\/contact-us\/\">\u041f\u043e\u043b\u0443\u0447\u0438\u0442\u044c \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/a> - \u041f\u043e\u0445\u043e\u0436\u0438\u0435: <a href=\"\/ru\/ac-mcb\/\">AC MCB<\/a>, <a href=\"\/ru\/%d1%80%d1%83%d1%87%d0%bd%d0%be%d0%b9-%d0%bf%d0%b5%d1%80%d0%b5%d0%ba%d0%bb%d1%8e%d1%87%d0%b0%d1%82%d0%b5%d0%bb%d1%8c\/\">\u0420\u0443\u0447\u043d\u043e\u0439 \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<\/a><\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"197\" data-end=\"269\">\n<p data-start=\"199\" data-end=\"269\"><strong data-start=\"199\" data-end=\"223\">Class I \/ Type 1 SPD<\/strong> for service entrance, 230\/400 V AC systems.<\/p>\n<\/li>\n<li data-start=\"270\" data-end=\"340\">\n<p data-start=\"272\" data-end=\"340\"><strong data-start=\"272\" data-end=\"314\">Impulse current Iimp 25 kA (10\/350 \u03bcs)<\/strong>, In 25 kA, Imax 100 kA.<\/p>\n<\/li>\n<li data-start=\"341\" data-end=\"428\">\n<p data-start=\"343\" data-end=\"428\"><strong data-start=\"343\" data-end=\"363\">Pluggable module<\/strong> with visual indicator, DIN-rail, optional remote signaling (RC).<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1578,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1283","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/product\/1283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/comments?post=1283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/media\/1578"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/media?parent=1283"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1283"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1283"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}