{"id":1194,"date":"2025-09-07T08:24:35","date_gmt":"2025-09-07T08:24:35","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1194"},"modified":"2025-09-07T08:24:35","modified_gmt":"2025-09-07T08:24:35","slug":"manual-transfer-switches-125a-4p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/pt\/product\/manual-transfer-switches-125a-4p\/","title":{"rendered":"Chave de transfer\u00eancia manual KYMTS-125A 4P"},"content":{"rendered":"<section id=\"overview-125a-4p\">\n<h2>Vis\u00e3o geral<\/h2>\n<p>O <strong>chaves de transfer\u00eancia manual<\/strong> (KYMTS-125A 4P) s\u00e3o projetados para sistemas CA trif\u00e1sicos + neutro que exigem comuta\u00e7\u00e3o de fonte confi\u00e1vel. A configura\u00e7\u00e3o de 4 polos oferece isolamento total de L1\/L2\/L3\/N durante a comuta\u00e7\u00e3o I-0-II entre a rede el\u00e9trica, o gerador ou o inversor fotovoltaico, garantindo seguran\u00e7a e conformidade m\u00e1ximas.<\/p>\n<p>Para comparar a s\u00e9rie completa do KYMTS, consulte a <a href=\"\/pt\/manual-transfer-switch\/\">Chave de transfer\u00eancia manual<\/a> p\u00e1gina inicial. Nas configura\u00e7\u00f5es de PV e ESS, a unidade 4P se integra com <a href=\"\/pt\/pv-combiner-box\/\">Caixas combinadoras fotovoltaicas<\/a>, upstream <a href=\"\/pt\/dc-breaker\/\">disjuntores<\/a>e <a href=\"\/pt\/dc-fuse\/\">Fus\u00edveis CC<\/a>. Consulte <a href=\"https:\/\/www.iec.ch\/\" target=\"_blank\" rel=\"noopener\">IEC<\/a> e <a href=\"https:\/\/ec.europa.eu\/growth\/single-market\/ce-marking\/\" target=\"_blank\" rel=\"noopener\">Certifica\u00e7\u00e3o CE<\/a> para conformidade com os padr\u00f5es.<\/p>\n<\/section>\n<section id=\"features-125a-4p\">\n<h2>Principais recursos<\/h2>\n<ul>\n<li><strong>125A, 4P<\/strong> comuta\u00e7\u00e3o manual com isolamento L1\/L2\/L3\/N.<\/li>\n<li>Al\u00e7a manual com <strong>I \/ 0 \/ II<\/strong> posi\u00e7\u00f5es para uma opera\u00e7\u00e3o segura.<\/li>\n<li>Alta condutividade <strong>contatos de cobre<\/strong> com baixo aumento de temperatura.<\/li>\n<li>Corpo compacto adequado para <strong>Painel \/ trilho DIN<\/strong> instala\u00e7\u00e3o.<\/li>\n<li>Ideal para <strong>transfer\u00eancia de gerador<\/strong>, bypass do inversor e quadros de distribui\u00e7\u00e3o comerciais.<\/li>\n<li>Atende <strong>IEC 60947-3<\/strong> padr\u00f5es de chaves seccionadoras.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs-125a-4p\">\n<h2>Especifica\u00e7\u00f5es<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Modelo<\/th>\n<td>KYMTS-125A 4P<\/td>\n<\/tr>\n<tr>\n<th>Postes<\/th>\n<td>4P (L1\/L2\/L3\/N)<\/td>\n<\/tr>\n<tr>\n<th>Corrente nominal (In)<\/th>\n<td>125A<\/td>\n<\/tr>\n<tr>\n<th>Tens\u00e3o operacional nominal (Ue)<\/th>\n<td>400V CA<\/td>\n<\/tr>\n<tr>\n<th>Frequ\u00eancia<\/th>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<th>Tens\u00e3o de isolamento (Ui)<\/th>\n<td>690V<\/td>\n<\/tr>\n<tr>\n<th>Montagem<\/th>\n<td>Trilho DIN \/ Painel<\/td>\n<\/tr>\n<tr>\n<th>Padr\u00e3o de refer\u00eancia<\/th>\n<td>IEC 60947-3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring-125a-4p\">\n<h2>Fia\u00e7\u00e3o e dimens\u00f5es<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1174\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-diagram-300x197.png\" alt=\"kumts-125-diagrama\" width=\"522\" height=\"343\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-diagram-300x197.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-diagram-600x394.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-diagram.png 632w\" sizes=\"auto, (max-width: 522px) 100vw, 522px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1175\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-dimension-300x183.png\" alt=\"kumts-125-dimension\" width=\"515\" height=\"314\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-dimension-300x183.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-dimension-768x468.png 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-dimension-600x366.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-125-dimension.png 919w\" sizes=\"auto, (max-width: 515px) 100vw, 515px\" \/><\/p>\n<\/section>\n<section id=\"applications-125a-4p\">\n<h2>Aplicativos<\/h2>\n<ul>\n<li>Comuta\u00e7\u00e3o de gerador comercial com isolamento de neutro<\/li>\n<li>Alimentadores industriais e placas MCC<\/li>\n<li>Bypass do inversor PV\/ESS com comuta\u00e7\u00e3o de polo completo<\/li>\n<li>Microgrid e sistemas de energia de backup<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq-125a-4p\">\n<h2>PERGUNTAS FREQUENTES<\/h2>\n<details>\n<summary>Para que s\u00e3o usadas as chaves de transfer\u00eancia manual?<\/summary>\n<p>As chaves de transfer\u00eancia manual alternam com seguran\u00e7a as cargas entre duas fontes de energia, como a rede el\u00e9trica e o gerador ou inversor, com isolamento total L1\/L2\/L3\/N.<\/p>\n<\/details>\n<details>\n<summary>Quando devo escolher um 4P em vez de um 3P?<\/summary>\n<p>Uma unidade 4P \u00e9 necess\u00e1ria quando a comuta\u00e7\u00e3o neutra \u00e9 necess\u00e1ria, garantindo a conformidade com os c\u00f3digos e a opera\u00e7\u00e3o segura do sistema.<\/p>\n<\/details>\n<details>\n<summary>Onde posso comparar os modelos KYMTS?<\/summary>\n<p>Visite o <a href=\"\/pt\/manual-transfer-switch\/\">Chave de transfer\u00eancia manual<\/a> p\u00e1gina de destino para todas as op\u00e7\u00f5es 1P\/2P\/3P\/4P.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta-125a-4p\">\n<h2>Precisa de uma cota\u00e7\u00e3o?<\/h2>\n<p>Procurando por produtos dur\u00e1veis <strong>chaves de transfer\u00eancia manual<\/strong>? <a href=\"\/pt\/contact-us\/\">Entre em contato conosco<\/a> hoje mesmo para obter planilhas de dados, pre\u00e7os e suporte.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"187\" data-end=\"287\">\n<p data-start=\"189\" data-end=\"287\">O <strong data-start=\"193\" data-end=\"221\">chaves de transfer\u00eancia manual<\/strong> 125A 4P fornecem isolamento total de L1\/L2\/L3\/N durante a troca.<\/p>\n<\/li>\n<li data-start=\"288\" data-end=\"361\">\n<p data-start=\"290\" data-end=\"361\">Al\u00e7a ergon\u00f4mica I-0-II, contatos de cobre, montagem em trilho DIN ou painel.<\/p>\n<\/li>\n<li data-start=\"362\" data-end=\"442\">\n<p data-start=\"364\" data-end=\"442\">Compat\u00edvel com a norma IEC 60947-3; ideal para sistemas comerciais, industriais e PV\/ESS.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1183,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":{"0":"post-1194","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-manual-transfer-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/product\/1194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/comments?post=1194"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/media\/1183"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/media?parent=1194"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1194"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1194"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}