{"id":2279,"date":"2025-12-15T09:19:15","date_gmt":"2025-12-15T09:19:15","guid":{"rendered":"https:\/\/cnkuangya.com\/?p=2279"},"modified":"2025-12-16T01:50:46","modified_gmt":"2025-12-16T01:50:46","slug":"matching-pv-combiner-box","status":"publish","type":"post","link":"https:\/\/cnkuangya.com\/pt\/blog\/matching-pv-combiner-box\/","title":{"rendered":"Correspond\u00eancia das classifica\u00e7\u00f5es de corrente e tens\u00e3o da caixa combinadora fotovoltaica"},"content":{"rendered":"<p>In a solar photovoltaic (PV) system, the combiner box plays a central role in consolidating power and ensuring safety. It&#8217;s a junction box where the output of multiple solar strings are connected in parallel, combining their current before sending it to the inverter. More importantly, it houses the critical overcurrent protection devices (fuses or circuit breakers) that protect the system&#8217;s wiring and components from potentially dangerous faults.<img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"1118\" class=\"wp-image-2282\" style=\"width: 750px;\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-scaled.jpg\" alt=\"\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-scaled.jpg 1717w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-201x300.jpg 201w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-687x1024.jpg 687w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-768x1145.jpg 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-1030x1536.jpg 1030w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-1374x2048.jpg 1374w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-8x12.jpg 8w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-300x447.jpg 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-600x894.jpg 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/p>\n\n\n\n<p>Dimensionar adequadamente seu <a href=\"https:\/\/cnkuangya.com\/pt\/pv-combiner-box\/\">Caixa combinadora fotovoltaica<\/a> and its internal components is not just a best practice\u2014it&#8217;s a fundamental requirement for a safe, reliable, and code-compliant installation. An undersized component can lead to fire hazards, while an oversized one may fail to provide adequate protection.<\/p>\n\n\n\n<p>This guide will walk you through the essential steps for matching your combiner box&#8217;s voltage and current ratings to your specific solar array, with a focus on the requirements outlined in the National Electrical Code (NEC). We will cover:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Princ\u00edpios b\u00e1sicos de seguran\u00e7a do artigo 690 do NEC<\/li>\n\n\n\n<li>C\u00e1lculo da tens\u00e3o m\u00e1xima do sistema com base nas condi\u00e7\u00f5es do local<\/li>\n\n\n\n<li>Dimensionamento de fus\u00edveis de string CC e prote\u00e7\u00e3o principal contra sobrecorrente<\/li>\n\n\n\n<li><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"500\" class=\"wp-image-2280\" style=\"width: 750px;\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring.webp\" alt=\"\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring.webp 700w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-300x200.webp 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-18x12.webp 18w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-600x400.webp 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/cdn.gooo.ai\/web-images\/f98a9597b933747a0375ac33ca63d7b9aa7aa76297f229a1af932c02b15e0289\" alt=\"Um diagrama que mostra os diferentes componentes dentro de uma caixa combinadora fotovoltaica, incluindo a entrada CC, os fus\u00edveis, os barramentos e o circuito de sa\u00edda.\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">A base: Entendendo o artigo 690 do NEC<\/h3>\n\n\n\n<p>Para qualquer instala\u00e7\u00e3o fotovoltaica nos Estados Unidos, o artigo 690 do NEC \u00e9 a autoridade m\u00e1xima. Essa se\u00e7\u00e3o do c\u00f3digo \u00e9 especificamente dedicada aos sistemas solares fotovoltaicos, abordando as caracter\u00edsticas exclusivas e os poss\u00edveis riscos da gera\u00e7\u00e3o de energia CC. Ela fornece a estrutura para tudo, desde a fia\u00e7\u00e3o e o aterramento at\u00e9 os meios de desconex\u00e3o e a prote\u00e7\u00e3o contra sobrecorrente. A ades\u00e3o ao Artigo 690 \u00e9 essencial para garantir que seu sistema seja seguro e passe na inspe\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parte 1: Correspond\u00eancia de tens\u00e3o do sistema fotovoltaico<\/h3>\n\n\n\n<p>O primeiro e mais importante par\u00e2metro a ser determinado \u00e9 a tens\u00e3o m\u00e1xima do sistema. Todos os componentes em um circuito, desde os fios at\u00e9 os fus\u00edveis e a pr\u00f3pria caixa combinadora, devem ter uma classifica\u00e7\u00e3o de tens\u00e3o igual ou superior \u00e0 tens\u00e3o m\u00e1xima que podem experimentar.<\/p>\n\n\n\n<p>In a PV system, the maximum voltage is determined by the number of modules in a series string and their open-circuit voltage (Voc), found on the module&#8217;s datasheet. However, voltage is inversely proportional to temperature; a solar panel&#8217;s voltage is highest on the coldest possible day. NEC requires you to calculate the maximum voltage for the lowest expected ambient temperature at your site.<\/p>\n\n\n\n<p><strong>Como calcular a tens\u00e3o m\u00e1xima do sistema:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Encontre o Voc:<\/strong> Look up the Open-Circuit Voltage (Voc) on your solar module&#8217;s datasheet.<\/li>\n\n\n\n<li><strong>Determinar a temperatura mais baixa:<\/strong> Encontre o recorde de baixa temperatura para a sua localiza\u00e7\u00e3o. Geralmente, voc\u00ea pode encontr\u00e1-la nos dados meteorol\u00f3gicos locais ou nas tabelas de temperatura de projeto da ASHRAE.<\/li>\n\n\n\n<li><strong>Encontre o fator de corre\u00e7\u00e3o de temperatura:<\/strong> A folha de dados do m\u00f3dulo fornecer\u00e1 um coeficiente de temperatura para Voc, expresso como uma porcentagem ou V\/\u00b0C. Use-o para encontrar o fator de corre\u00e7\u00e3o para sua temperatura mais baixa em rela\u00e7\u00e3o \u00e0 temperatura da condi\u00e7\u00e3o de teste padr\u00e3o (STC) de 25\u00b0C. O NEC fornece tabelas em 690.7 para um c\u00e1lculo simplificado.<\/li>\n\n\n\n<li><strong>Calcular o Voc. corrigido<\/strong> <code>Voc corrigido = Voc \u00d7 [1 + (temperatura mais baixa \u00b0C - 25\u00b0C) \u00d7 (coeficiente de temperatura Voc %\/\u00b0C)]<\/code><\/li>\n\n\n\n<li><strong>Calcule a tens\u00e3o m\u00e1xima do sistema:<\/strong> <code>Tens\u00e3o m\u00e1xima do sistema = Voc corrigido \u00d7 n\u00famero de m\u00f3dulos em s\u00e9rie<\/code><\/li>\n<\/ol>\n\n\n\n<p><strong>Exemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Voc do m\u00f3dulo: 48,5V<\/li>\n\n\n\n<li>Temperatura mais baixa do local: -10\u00b0C<\/li>\n\n\n\n<li>N\u00famero de m\u00f3dulos por string: 12<\/li>\n\n\n\n<li>Coeficiente de temperatura Voc: -0,28%\/\u00b0C<\/li>\n\n\n\n<li>Voc corrigido = <code>48.5V \u00d7 [1 + (-10 - 25) \u00d7 (-0.0028)]<\/code> = <code>48.5V \u00d7 [1 + (-35 \u00d7 -0.0028)]<\/code> = <code>48.5V \u00d7 1.098<\/code> = 53.25V<\/li>\n\n\n\n<li><strong>Tens\u00e3o m\u00e1xima do sistema<\/strong> = <code>53.25V \u00d7 12<\/code> = <strong>639V<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Nesse caso, o sistema requer uma caixa combinadora, fus\u00edveis e disjuntores classificados para pelo menos 639 V. Portanto, voc\u00ea selecionaria componentes de uma classe padr\u00e3o de 1000 V CC, pois os componentes de 600 V seriam insuficientes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parte 2: <a href=\"https:\/\/cnkuangya.com\/pt\/pv-combiner-box\/\">Caixa combinadora fotovoltaica<\/a> Dimensionamento e fus\u00e3o de cordas CC<\/h3>\n\n\n\n<p>Ap\u00f3s determinar a classifica\u00e7\u00e3o de tens\u00e3o, a pr\u00f3xima etapa \u00e9 dimensionar os dispositivos de prote\u00e7\u00e3o contra sobrecorrente (OCPDs), que normalmente s\u00e3o fus\u00edveis. O objetivo principal dos fus\u00edveis de string \u00e9 proteger contra a corrente reversa. Uma falha em um string pode fazer com que outros strings sejam realimentados por ele, criando uma condi\u00e7\u00e3o perigosa de sobrecorrente.<\/p>\n\n\n\n<p>De acordo com a norma NEC 690.9, a fus\u00edvel de n\u00edvel de fio \u00e9 necess\u00e1ria sempre que voc\u00ea tiver <strong>tr\u00eas ou mais cadeias de caracteres em paralelo<\/strong>. With only two strings, the reverse current potential is not high enough to exceed the module&#8217;s fuse rating, so fuses are not required by code (though they are still sometimes used as a disconnecting means).<\/p>\n\n\n\n<p><strong>Como dimensionar fus\u00edveis de cordas:<\/strong><\/p>\n\n\n\n<p>The NEC requires that the fuse be rated to handle continuous duty and potential irradiance spikes. This is accomplished by multiplying the module&#8217;s Short-Circuit Current (Isc) by a factor of 1.56.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>1,25 fator<\/strong> para carga cont\u00ednua (circuitos que podem operar por mais de 3 horas).<\/li>\n\n\n\n<li><strong>1,25 fator<\/strong> for potential &#8220;irradiance enhancement&#8221; where sun exposure can exceed the standard 1000 W\/m\u00b2.<\/li>\n\n\n\n<li><code>1.25 \u00d7 1.25 = 1.56<\/code><\/li>\n<\/ul>\n\n\n\n<p><strong>F\u00f3rmula de classifica\u00e7\u00e3o do fus\u00edvel:<\/strong> <code>Classifica\u00e7\u00e3o m\u00ednima do fus\u00edvel \u2265 Isc do m\u00f3dulo \u00d7 1,56<\/code><\/p>\n\n\n\n<p>Ap\u00f3s calcular esse m\u00ednimo, voc\u00ea seleciona o pr\u00f3ximo tamanho de fus\u00edvel padr\u00e3o acima.<\/p>\n\n\n\n<p><strong>Limita\u00e7\u00e3o crucial: Classifica\u00e7\u00e3o m\u00e1xima do fus\u00edvel em s\u00e9rie<\/strong>\\<br>Every solar module has a &#8220;Maximum Series Fuse Rating&#8221; listed on its datasheet. This value is an absolute limit. <strong>O tamanho calculado do fus\u00edvel n\u00e3o deve exceder essa classifica\u00e7\u00e3o.<\/strong> Se isso acontecer, o projeto do seu sistema est\u00e1 com defeito, o que normalmente significa que o m\u00f3dulo escolhido n\u00e3o pode ser usado com esse n\u00famero de strings em paralelo.<\/p>\n\n\n\n<p><strong>Exemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Isc do m\u00f3dulo: 10.5A<\/li>\n\n\n\n<li>Classifica\u00e7\u00e3o m\u00e1xima de fus\u00edveis da s\u00e9rie do m\u00f3dulo: 20A<\/li>\n\n\n\n<li>Classifica\u00e7\u00e3o m\u00ednima do fus\u00edvel = <code>10.5A \u00d7 1.56<\/code> = <strong>16.38A<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Com base nesse c\u00e1lculo, voc\u00ea escolheria o pr\u00f3ximo tamanho padr\u00e3o acima, que \u00e9 um <strong>20A<\/strong> fuse. Since 20A is equal to the module&#8217;s maximum series fuse rating, this is a valid selection. If the calculation had resulted in 21A, you would not be able to use a 25A fuse, and the design would need to be re-evaluated.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/cdn.gooo.ai\/web-images\/357e85dc73b217fa84fb935d7868800fccfd950772178c1989038765798e398e\" alt=\"Uma caixa combinadora solar aberta mostrando a fia\u00e7\u00e3o interna, os barramentos e os suportes de fus\u00edveis.\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Parte 3: Coordena\u00e7\u00e3o da prote\u00e7\u00e3o contra sobrecorrente<\/h3>\n\n\n\n<p>A coordena\u00e7\u00e3o da prote\u00e7\u00e3o garante que, no caso de uma falha, o OCPD correto abra primeiro. No caso de uma falha em um \u00fanico string, o fus\u00edvel individual do string deve queimar, isolando apenas esse string sem colocar todo o array off-line. O OCPD principal na sa\u00edda da caixa combinadora s\u00f3 deve disparar se houver uma falha grave nos condutores principais que levam ao inversor.<\/p>\n\n\n\n<p>Isso \u00e9 feito garantindo que o dispositivo downstream tenha uma classifica\u00e7\u00e3o mais baixa do que o dispositivo upstream.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Componente<\/strong><\/th><th><strong>Finalidade<\/strong><\/th><th><strong>Regra geral de dimensionamento<\/strong><\/th><th><strong>Refer\u00eancia NEC<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Fus\u00edvel de corda<\/strong><\/td><td>Protege strings individuais de falhas de corrente reversa de outras strings.<\/td><td><code>Isc \u00d7 1,56<\/code> (e deve ser \u2264 a classifica\u00e7\u00e3o m\u00e1xima do fus\u00edvel do m\u00f3dulo)<\/td><td><code>690.9(A)<\/code><\/td><\/tr><tr><td><strong>Combinador principal OCPD<\/strong><\/td><td>Protege o fio de sa\u00edda principal da caixa combinadora para o inversor.<\/td><td>Soma de todas as classifica\u00e7\u00f5es de fus\u00edveis de string, arredondada para o tamanho de disjuntor padr\u00e3o mais pr\u00f3ximo. Ou <code>(Isc total \u00d7 1,25)<\/code> e selecione o pr\u00f3ximo tamanho padr\u00e3o de OCPD acima.<\/td><td><code>690.9(A)<\/code> &amp; <code>240.4<\/code><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Perguntas frequentes (FAQ)<\/h3>\n\n\n\n<p><strong>Preciso de fus\u00edveis para apenas duas cadeias de caracteres paralelas?<\/strong>\\<br>No. According to NEC 690.9, overcurrent protection is only required when there are three or more strings in parallel. With two strings, the maximum fault current that one string can source to the other is limited to the Isc of one string, which is below the module&#8217;s maximum fuse rating.<\/p>\n\n\n\n<p><strong>Posso usar fus\u00edveis ou disjuntores com classifica\u00e7\u00e3o CA para circuitos CC?<\/strong>\\<br>N\u00e3o, voc\u00ea deve usar componentes classificados especificamente para circuitos CC. Os arcos de CC s\u00e3o muito mais dif\u00edceis de serem extintos do que os arcos de CA. Um dispositivo classificado para CA provavelmente n\u00e3o conseguir\u00e1 interromper com seguran\u00e7a uma falha de CC, levando a um risco significativo de inc\u00eandio e seguran\u00e7a.<\/p>\n\n\n\n<p><strong>O que acontece se eu instalar o fus\u00edvel de tamanho errado?<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Muito pequeno:<\/strong> The fuse will be subject to &#8220;nuisance tripping,&#8221; blowing under normal operating conditions (e.g., on a cool, very sunny day), causing unnecessary system downtime.<\/li>\n\n\n\n<li><strong>Muito grande:<\/strong> A fuse that is too large (especially one exceeding the module&#8217;s Maximum Series Fuse Rating) will not protect the module from damaging reverse currents. This can lead to module failure and creates a fire risk.<\/li>\n<\/ul>\n\n\n\n<p><strong>Por que o multiplicador de 1,56 \u00e9 usado para dimensionamento?<\/strong>\\<br>It&#8217;s a combined safety factor required by the NEC. It consists of two separate 1.25 multipliers: one to account for the fact that solar circuits are considered &#8220;continuous loads&#8221; (running at max current for more than 3 hours), and a second to account for irradiance levels that can exceed standard test conditions, causing current to rise temporarily above the rated Isc. (1.25 x 1.25 = 1.56).<\/p>\n\n\n\n<p><strong>Qual \u00e9 a \u201cClassifica\u00e7\u00e3o m\u00e1xima de fus\u00edveis em s\u00e9rie\u201d de um m\u00f3dulo?<\/strong>\\<br>Essa \u00e9 uma classifica\u00e7\u00e3o de seguran\u00e7a determinada pelo fabricante do m\u00f3dulo e certificada pela UL. Ela especifica a corrente m\u00e1xima que o m\u00f3dulo pode suportar sem ser danificado quando submetido a uma corrente reversa. Voc\u00ea nunca deve instalar um fus\u00edvel ou OCPD com classifica\u00e7\u00e3o superior a esse valor.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"1024\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-687x1024.jpg\" alt=\"\" class=\"wp-image-2281\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-687x1024.jpg 687w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-201x300.jpg 201w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-768x1145.jpg 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-1030x1536.jpg 1030w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-1374x2048.jpg 1374w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-8x12.jpg 8w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-300x447.jpg 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-600x894.jpg 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-scaled.jpg 1717w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Conclus\u00e3o<\/h3>\n\n\n\n<p>Matching a PV combiner box&#8217;s current and voltage ratings is a systematic process guided by engineering principles and the strict safety standards of the NEC. The core takeaways are:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Tens\u00e3o em primeiro lugar:<\/strong> Sempre determine a tens\u00e3o m\u00e1xima do sistema usando a temperatura mais baixa esperada para seu local. Todos os componentes devem ser classificados para essa tens\u00e3o.<\/li>\n\n\n\n<li><strong>Segundo atual:<\/strong> Size string fuses based on the module&#8217;s Isc and the 1.56x multiplier, but never exceed the module&#8217;s Maximum Series Fuse Rating.<\/li>\n\n\n\n<li><strong>O c\u00f3digo \u00e9 fundamental:<\/strong> When in doubt, defer to NEC Article 690 and the manufacturer&#8217;s datasheets for all components.<\/li>\n<\/ol>\n\n\n\n<p>By following these guidelines, you can ensure your solar array&#8217;s combiner box is sized safely, reliably, and professionally, forming a robust foundation for your entire PV system.<\/p>","protected":false},"excerpt":{"rendered":"<p>In a solar photovoltaic (PV) system, the combiner box plays a central role in consolidating power and ensuring safety. It&#8217;s a junction box where the output of multiple solar strings are connected in parallel, combining their current before sending it to the inverter. More importantly, it houses the critical overcurrent protection devices (fuses or circuit [&hellip;]<\/p>","protected":false},"author":4,"featured_media":2285,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[35],"tags":[],"class_list":["post-2279","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/posts\/2279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/comments?post=2279"}],"version-history":[{"count":1,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/posts\/2279\/revisions"}],"predecessor-version":[{"id":2283,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/posts\/2279\/revisions\/2283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/media\/2285"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/media?parent=2279"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/categories?post=2279"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/pt\/wp-json\/wp\/v2\/tags?post=2279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}