{"id":968,"date":"2025-09-02T07:31:05","date_gmt":"2025-09-02T07:31:05","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=968"},"modified":"2025-09-14T06:37:35","modified_gmt":"2025-09-14T06:37:35","slug":"dc-spd-t1-t2-1000vdc","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ko\/product\/dc-spd-t1-t2-1000vdc\/","title":{"rendered":"KY-15T\/G1000 - T1+T2 DC \uc11c\uc9c0 \ubcf4\ud638 \uc7a5\uce58 (1000V)"},"content":{"rendered":"<section id=\"overview\">\n<h2>Overview<\/h2>\n<p>The <strong>1000v dc spd t1+t2<\/strong> KY-15T\/G1000 is a surge protective device engineered for<br \/>\n<a href=\"\/pv-combiner-box\">PV combiner boxes<\/a>, DC feeders, and inverter DC inputs up to 1000VDC.<br \/>\nIt provides coordinated Type 1+2 protection against lightning currents and switching surges,<br \/>\nreducing residual voltage to safeguard sensitive PV equipment.<br \/>\nFully compliant with <a href=\"https:\/\/webstore.iec.ch\/publication\/26146\" target=\"_blank\" rel=\"noopener\">IEC 61643-31<\/a> and certified CE, UKCA, and RoHS.<\/p>\n<\/section>\n<section id=\"key-features\">\n<h2>Key Features<\/h2>\n<ul>\n<li>Combined <strong>1000v dc spd t1+t2<\/strong> protection for photovoltaic DC circuits.<\/li>\n<li>Clear status indicator and replaceable cartridge for easy maintenance.<\/li>\n<li>Remote alarm contact terminals reserved (per datasheet specifications).<\/li>\n<li>Compact, flame-retardant enclosure (UL94-V0) with 35mm DIN-rail mounting.<\/li>\n<li>Coordinates with <a href=\"\/dc-fuse\">gPV fuses<\/a> and<br \/>\n<a href=\"\/dc-switch-disconnector\">DC switch disconnectors<\/a> in a<br \/>\n<a href=\"\/dc-spd\">complete surge protection system<\/a>.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h2>Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Type<\/th>\n<td>T1+T2<\/td>\n<\/tr>\n<tr>\n<th>System Voltage (U<sub>cpv<\/sub>)<\/th>\n<td>1000 V DC<\/td>\n<\/tr>\n<tr>\n<th>Nominal Discharge Current (I<sub>n<\/sub>)<\/th>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<th>Maximum Discharge Current (I<sub>max<\/sub>)<\/th>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<th>Impulse Current (I<sub>imp<\/sub>)<\/th>\n<td>6.25 kA<\/td>\n<\/tr>\n<tr>\n<th>Voltage Protection Level (U<sub>p<\/sub>)<\/th>\n<td>\u2264 3.5 kV<\/td>\n<\/tr>\n<tr>\n<th>Response Time (t<sub>a<\/sub>)<\/th>\n<td>&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<th>Admissible Short-Circuit Current (I<sub>scpv<\/sub>)<\/th>\n<td>10 kA<\/td>\n<\/tr>\n<tr>\n<th>Remote Alarm Contact<\/th>\n<td>220V, 0.5A, NO\/NC<\/td>\n<\/tr>\n<tr>\n<th>Standards<\/th>\n<td>IEC 61643-31, GB\/T 18802.31, CE, UKCA, RoHS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"diagram\">\n<h2>Wiring &amp; Dimension<\/h2>\n<p>Wiring:<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-970\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Wiring-Diagram-300x231.png\" alt=\"Wiring diagram of KY T1+T2 DC SPD surge protective device for 1000V and 1500V photovoltaic systems\" width=\"444\" height=\"342\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Wiring-Diagram-300x231.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Wiring-Diagram.png 554w\" sizes=\"auto, (max-width: 444px) 100vw, 444px\" \/><\/p>\n<\/section>\n<p>Dimension:<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-969\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension-300x149.png\" alt=\"Dimension drawing of KY T1+T2 DC surge protective device for PV combiner box and inverter protection\" width=\"409\" height=\"203\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension-300x149.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension-600x299.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension.png 753w\" sizes=\"auto, (max-width: 409px) 100vw, 409px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<section id=\"diagram\">\n<h2>Applications<\/h2>\n<\/section>\n<section id=\"applications\">\n<ul>\n<li>PV combiner boxes and inverter DC terminals requiring T1+T2 SPD protection.<\/li>\n<li>Main DC feeders in utility-scale and ground-mount solar plants.<\/li>\n<li>Commercial and industrial rooftop solar PV systems with high surge exposure.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h2>FAQs<\/h2>\n<h3>Q1. What is the difference between a 1000v dc spd t1+t2 and a type 2 only SPD?<\/h3>\n<p>The KY-15T\/G1000 combines Type 1 lightning current capability with Type 2 low residual voltage protection,<br \/>\nwhile Type 2 alone cannot handle direct lightning currents.<\/p>\n<h3>Q2. Can the 1000v dc spd t1+t2 be used in residential PV combiner boxes?<\/h3>\n<p>Yes, it is suitable for residential and commercial PV combiner boxes operating at 1000V DC.<\/p>\n<h3>Q3. Does KY-15T\/G1000 include remote alarm contacts?<\/h3>\n<p>Yes, alarm terminals (NO\/NC) are reserved and rated 220V, 0.5A as specified in the datasheet.<\/p>\n<h3>Q4. Which standards does the KY-15T\/G1000 comply with?<\/h3>\n<p>IEC 61643-31, GB\/T 18802.31, CE, UKCA, and RoHS certifications are covered.<\/p>\n<\/section>\n<p><!-- ========================= JSON-LD: FAQ ONLY ========================= --><br \/>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between a 1000v dc spd t1+t2 and a type 2 only SPD?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The KY-15T\/G1000 combines Type 1 lightning current capability with Type 2 low residual voltage protection, making it suitable for main PV protection points.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the 1000v dc spd t1+t2 be used in residential PV combiner boxes?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, it is designed for residential and commercial PV combiner boxes operating at 1000V DC.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does KY-15T\/G1000 include remote alarm contacts?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, alarm terminals (NO\/NC) are reserved and rated 220V, 0.5A as specified in the datasheet.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which standards does the KY-15T\/G1000 comply with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"IEC 61643-31, GB\/T 18802.31, CE, UKCA, and RoHS certifications are covered.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<section id=\"cta\"><a class=\"btn\" href=\"\/contact-us\">Request a Quote for 1000v dc spd t1+t2<\/a><\/section>\n","protected":false},"excerpt":{"rendered":"<p>(1) <strong data-start=\"276\" data-end=\"298\">1000V DC SPD T1+T2<\/strong> KY-15T\/G1000\uc740 \ud0dc\uc591\uad11 \uc2dc\uc2a4\ud15c\uc744 \uc704\ud55c \ud1b5\ud569\ud615 1+2 \uc11c\uc9c0 \ubcf4\ud638 \uae30\ub2a5\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<p><br data-start=\"381\" data-end=\"384\" \/>(2) IEC 61643-31 \ubc0f CE\/UKCA\/RoHS \ud45c\uc900\uc744 \uc900\uc218\ud558\ub294 PV \ucef4\ubc14\uc774\ub108 \ubc15\uc2a4, \uc778\ubc84\ud130 \ubc0f DC \ud53c\ub354\uc6a9\uc73c\ub85c \uc124\uacc4\ub418\uc5c8\uc2b5\ub2c8\ub2e4.<\/p>\n<p><br data-start=\"502\" data-end=\"505\" \/>(3) \uc6d0\uaca9 \uc54c\ub78c \uc811\uc810 \uc635\uc158, \uad50\uccb4 \uac00\ub2a5\ud55c \ubaa8\ub4c8 \uc124\uacc4, T1+T2 \uc2dc\ub9ac\uc988\uc6a9 \uacf5\uc720 \ubc30\uc120\/\uce58\uc218 \ub2e4\uc774\uc5b4\uadf8\ub7a8\uc774 \ud3ec\ud568\ub418\uc5b4 \uc788\uc2b5\ub2c8\ub2e4.<\/p>","protected":false},"featured_media":1534,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[26],"product_tag":[],"class_list":{"0":"post-968","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-dc-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product\/968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/comments?post=968"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media\/1534"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media?parent=968"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_brand?post=968"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_cat?post=968"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_tag?post=968"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}