{"id":786,"date":"2025-08-29T09:26:33","date_gmt":"2025-08-29T09:26:33","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=786"},"modified":"2025-08-30T09:18:58","modified_gmt":"2025-08-30T09:18:58","slug":"dc-fuse-switch-disconnector-l2","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ko\/product\/dc-fuse-switch-disconnector-l2\/","title":{"rendered":"L2 \uc2dc\ub9ac\uc988 DC \uc2a4\uc704\uce58-\ub2e8\ub85c\uae30 | \ube68\uac04\uc0c9\/\ub178\ub780\uc0c9 \uc190\uc7a1\uc774 \ub204\ub984 \uc7a0\uae08\uc7a5\uce58"},"content":{"rendered":"<div class=\"product-description\">\n<h2>\uac1c\uc694<\/h2>\n<p>\uadf8\ub9ac\uace0 <strong>DC \ud4e8\uc988 \uc2a4\uc704\uce58-\ub2e8\ub85c\uae30<\/strong> L2 series combines reliable electrical performance with<br \/>\nenhanced operator visibility. With ratings up to <strong>1200VDC<\/strong> in <strong>2P \ubc0f 4P<\/strong> \ubaa8\ub378,<br \/>\nit is designed for <a href=\"\/ko\/pv-combiner-box\/\">PV \ucef4\ubc14\uc774\ub108 \ubc15\uc2a4<\/a> \ubc0f<br \/>\n<a href=\"\/ko\/dc-%ed%83%9c%ec%96%91%ea%b4%91-%eb%b3%b4%ed%98%b8\/\">DC \ud328\ub110<\/a>.<br \/>\nThe L2 features a distinctive **red rotary handle with a yellow safety plate**, using a <em>press-to-lock<\/em> mechanism<br \/>\nfor fast and secure isolation, making it suitable for industrial and commercial PV systems.<\/p>\n<h2>\uc8fc\uc694 \uae30\ub2a5<\/h2>\n<ul>\n<li><strong>DIN-rail mounted dc fuse switch-disconnector<\/strong>, IP20<\/li>\n<li>Red\/yellow handle with press-to-lock design for high visibility<\/li>\n<li>2P and 4P models available, polarity-free wiring<\/li>\n<li>\uc804\uc555 \ub4f1\uae09: 300 \/ 600 \/ 800 \/ 1000 \/ 1200 VDC<\/li>\n<li>\uc804\ub958 \uc815\uaca9: 16A \/ 25A \/ 32A<\/li>\n<li>Durability: 18k mechanical \/ 2k electrical operations<\/li>\n<li>\ub0b4\uc804\uc555: 1kA, 1\ucd08 \ub2e8\uc2dc\uac04; 8.0kV \uc784\ud384\uc2a4<\/li>\n<li>\ud45c\uc900: <a href=\"https:\/\/webstore.iec.ch\/publication\/26113\" target=\"_blank\" rel=\"dofollow noopener\">IEC 60947-3<\/a><\/li>\n<\/ul>\n<h2>\uc804\uae30\uc801 \ud2b9\uc131<\/h2>\n<table>\n<tbody>\n<tr>\n<td>\uae30\ub2a5<\/td>\n<td>\uc544\uc774\uc194\ub808\uc774\ud130, \uc81c\uc5b4<\/td>\n<\/tr>\n<tr>\n<td>\ud3f4 \uc635\uc158<\/td>\n<td>2P \/ 4P<\/td>\n<\/tr>\n<tr>\n<td>\uc815\uaca9 \uc791\ub3d9 \uc804\uc555(Ue)<\/td>\n<td>300-1200 VDC<\/td>\n<\/tr>\n<tr>\n<td>\uc815\uaca9 \uc808\uc5f0 \uc804\uc555(Ui)<\/td>\n<td>1200 VDC<\/td>\n<\/tr>\n<tr>\n<td>\ub2e8\uc2dc\uac04 \ub0b4\uc804\ub958(Icw)<\/td>\n<td>1kA, 1\ucd08<\/td>\n<\/tr>\n<tr>\n<td>\uc784\ud384\uc2a4 \ub0b4\uc804\uc555(Uimp)<\/td>\n<td>8.0kV<\/td>\n<\/tr>\n<tr>\n<td>\uc778\uadf8\ub808\uc2a4 \ubcf4\ud638<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>\uc9c0\uad6c\ub825<\/td>\n<td>\uae30\uacc4\uc2dd 18,000\uac1c\/\uc804\uae30\uc2dd 2,000\uac1c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\uc815\uaca9 \uc804\uc555\/\uc804\ub958<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\uc720\ud615<\/th>\n<th>300V<\/th>\n<th>600V<\/th>\n<th>800V<\/th>\n<th>1000V<\/th>\n<th>1200V<\/th>\n<\/tr>\n<tr>\n<td>FMPV16-L2<\/td>\n<td>16A<\/td>\n<td>16A<\/td>\n<td>12A<\/td>\n<td>8A<\/td>\n<td>6A<\/td>\n<\/tr>\n<tr>\n<td>FMPV25-L2<\/td>\n<td>25A<\/td>\n<td>25A<\/td>\n<td>15A<\/td>\n<td>9A<\/td>\n<td>7A<\/td>\n<\/tr>\n<tr>\n<td>FMPV32-L2<\/td>\n<td>32A<\/td>\n<td>32A<\/td>\n<td>17A<\/td>\n<td>10A<\/td>\n<td>8A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\uc2a4\uc704\uce6d \uad6c\uc131<\/h2>\n<ul>\n<li>2P \u2013 single PV string<\/li>\n<li>4P \u2013 dual strings isolation<\/li>\n<li>4T \/ 4B \/ 4S \u2013 series wiring options<\/li>\n<li>2H \u2013 parallel poles for higher current<\/li>\n<\/ul>\n<h2>\uce58\uc218<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-785\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/08\/L2-switch-disconnector-300x166.png\" alt=\"dc fuse switch-disconnector dimension\" width=\"614\" height=\"340\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/08\/L2-switch-disconnector-300x166.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/08\/L2-switch-disconnector-600x331.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/08\/L2-switch-disconnector.png 744w\" sizes=\"auto, (max-width: 614px) 100vw, 614px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>\uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/h2>\n<p>The L2 <strong>DC \ud4e8\uc988 \uc2a4\uc704\uce58-\ub2e8\ub85c\uae30<\/strong> is recommended for PV systems where high visibility of<br \/>\nthe isolator switch is important. The red\/yellow handle provides clear operator indication.<br \/>\n\uc774\uc0c1\uc801\uc778 \ub300\uc0c1 <a href=\"\/ko\/pv-combiner-box\/\">PV \ucef4\ubc14\uc774\ub108 \ubc15\uc2a4<\/a>,<br \/>\n<a href=\"\/ko\/dc-%ed%83%9c%ec%96%91%ea%b4%91-%eb%b3%b4%ed%98%b8\/\">DC \ud328\ub110<\/a>, \ubc0f \uc778\ubc84\ud130 DC \uc785\ub825.<br \/>\n\ub2e4\uc74c \ud56d\ubaa9\uacfc \uacb0\ud569 <a href=\"\/ko\/dc-fuse\/\">DC \ud4e8\uc988<\/a> \ubc0f <a href=\"\/ko\/dc-spd\/\">surge protectors<\/a> \uc644\ubcbd\ud55c \uc548\uc804\uc744 \uc704\ud574<\/p>\n<\/div>\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<p><strong>Q1: What is the L2 dc fuse switch-disconnector used for?<\/strong><br \/>\nA1: The L2 is designed for isolating PV circuits in DC distribution panels and combiner boxes, providing high visibility during maintenance.<\/p>\n<p><strong>Q2: What versions are available in the L2 series?<\/strong><br \/>\nA2: The L2 is available in 2-pole (2P) and 4-pole (4P) versions, supporting up to 1200VDC.<\/p>\n<p><strong>Q3: What is the handle design of the L2?<\/strong><br \/>\nA3: The L2 features a red rotary handle with a yellow safety plate, using a press-to-lock mechanism.<\/p>\n<p><strong>Q4: What is the ingress protection level of L2?<\/strong><br \/>\nA4: L2\ub294 IP20 \ub4f1\uae09\uc73c\ub85c \uc2e4\ub0b4 \uc124\uce58\uc5d0 \uc801\ud569\ud569\ub2c8\ub2e4.<\/p>\n<p><strong>Q5: Does the L2 comply with IEC standards?<\/strong><br \/>\nA5: Yes, it complies with <a href=\"https:\/\/webstore.iec.ch\/publication\/26113\" target=\"_blank\" rel=\"dofollow noopener\">IEC 60947-3<\/a>.<\/p>\n<p><strong>Q6: What endurance does the L2 provide?<\/strong><br \/>\nA6: The L2 offers 18,000 mechanical and 2,000 electrical operations.<\/p>\n<p><strong>Q7: Can L2 be installed on DIN-rails?<\/strong><br \/>\nA7: Yes, the L2 is designed for 35 mm DIN-rail mounting inside DC panels.<\/p>\n<p><strong>Q8: \ud604\uc7ac \uc5b4\ub5a4 \ub4f1\uae09\uc774 \uc9c0\uc6d0\ub418\ub098\uc694?<\/strong><br \/>\nA8: Models are available for 16A, 25A, and 32A applications.<\/p>\n<p><strong>Q9: What applications are best suited for L2?<\/strong><br \/>\nA9: L2 is recommended for commercial and industrial PV systems that require high visibility isolators with clear ON\/OFF status indication.<\/p>\n<p><strong>Q10: Is OEM\/ODM support offered?<\/strong><br \/>\nA10: Yes, customized labeling and design support are available.<\/p>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"4672\" data-end=\"4753\">\n<p data-start=\"4675\" data-end=\"4753\">L2 series <strong data-start=\"4685\" data-end=\"4716\">DC \ud4e8\uc988 \uc2a4\uc704\uce58-\ub2e8\ub85c\uae30<\/strong>, \ucd5c\ub300 1200VDC\uae4c\uc9c0 2P\/4P\ub85c \uc81c\uacf5\ub429\ub2c8\ub2e4.<\/p>\n<\/li>\n<li data-start=\"4754\" data-end=\"4837\">\n<p data-start=\"4757\" data-end=\"4837\">DIN-rail type, IP20, <strong data-start=\"4778\" data-end=\"4815\">red\/yellow high-visibility handle<\/strong> with press-to-lock.<\/p>\n<\/li>\n<li data-start=\"4838\" data-end=\"4913\">\n<p data-start=\"4841\" data-end=\"4913\">IEC 60947-3 compliant; safe solution for PV panels and combiner boxes.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":825,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[24],"product_tag":[],"class_list":{"0":"post-786","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-dc-switch-disconnector","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product\/786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/comments?post=786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media\/825"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media?parent=786"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_brand?post=786"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_cat?post=786"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_tag?post=786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}