{"id":1526,"date":"2025-09-13T07:24:34","date_gmt":"2025-09-13T07:24:34","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1526"},"modified":"2026-01-20T08:41:54","modified_gmt":"2026-01-20T08:41:54","slug":"afdd-1-arc-fault-detection-device","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ko\/product\/afdd-1-arc-fault-detection-device\/","title":{"rendered":"AFDD-1 \uc544\ud06c \uacb0\ud568 \uac10\uc9c0 \uc7a5\uce58 | RCBO \uae30\ub2a5\uc73c\ub85c \ud654\uc7ac \ubc29\uc9c0"},"content":{"rendered":"<section id=\"product-description\" class=\"description\"><!-- Overview --><\/p>\n<h2>\uac1c\uc694<\/h2>\n<p>\uadf8\ub9ac\uace0 <strong>AFDD-1<\/strong> Arc Fault Detection Device integrates <em>\uc544\ud06c \uacb0\ud568 \uac10\uc9c0(AFDD)<\/em>,<br \/>\n<em>\uacfc\uc804\ub958 \ubcf4\ud638(MCB)<\/em> \ubc0f <em>\uc794\ub958 \uc804\ub958 \ubcf4\ud638(RCCB, A\ud615)<\/em> in one compact 1P+N module.<br \/>\nIt complies with <strong>EN62606<\/strong> \ubc0f <strong>EN61009-1<\/strong>, providing early detection of series\/parallel arc faults<br \/>\nand fast disconnection to reduce fire risks in residential, commercial and industrial installations.<\/p>\n<p><!-- Features --><\/p>\n<h2>\ud2b9\uc9d5<\/h2>\n<ul>\n<li>3\uc911 \ubcf4\ud638: <strong>AFDD + MCB + RCCB(Type A)<\/strong><\/li>\n<li>Rated short-circuit capacity: <strong>6 kA<\/strong>; tripping curves: <strong>B\/C<\/strong><\/li>\n<li>LED indication for device status &amp; tripping reason; continuous self-monitoring<\/li>\n<li>\ucef4\ud329\ud2b8 <strong>1P+N(\ubaa8\ub4c8 1\uac1c)<\/strong> design, screw terminals top\/bottom<\/li>\n<li>Strain-relief clamps, snap-in slider; easy mounting on <strong>35mm DIN \ub808\uc77c<\/strong><\/li>\n<li>Mechanical endurance \u2265 <strong>20,000<\/strong> cycles; Electrical endurance \u2265 <strong>4,000<\/strong> cycles<\/li>\n<\/ul>\n<p><!-- Technical Data --><\/p>\n<h2>\uae30\uc220 \ub370\uc774\ud130<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>\uc2dc\ub9ac\uc988<\/th>\n<td>AFDD<\/td>\n<\/tr>\n<tr>\n<th>\ubaa8\ub378<\/th>\n<td>AFDD-1<\/td>\n<\/tr>\n<tr>\n<th>\ud3f4<\/th>\n<td>1P+N(1 \ubaa8\ub4c8)<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \uc804\ub958(AC)<\/th>\n<td>6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A<\/td>\n<\/tr>\n<tr>\n<th>\uc794\ub958 \uc804\ub958 \uc720\ud615<\/th>\n<td>\uc720\ud615 A<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \uc794\ub958 \uc804\ub958 I\u0394n<\/th>\n<td>10mA, 30mA<\/td>\n<\/tr>\n<tr>\n<th>\ucd5c\uc18c\/\ucd5c\ub300 \ud14c\uc2a4\ud2b8 \ud68c\ub85c \uc804\uc555<\/th>\n<td>196V \/ 253V<\/td>\n<\/tr>\n<tr>\n<th>\ud2b8\ub9bd \ud2b9\uc131<\/th>\n<td>B, C<\/td>\n<\/tr>\n<tr>\n<th>\uc791\ub3d9 \uc8fc\ud30c\uc218<\/th>\n<td>50Hz<\/td>\n<\/tr>\n<tr>\n<th>\uc784\ud384\uc2a4 \ub0b4\uc804\uc555(Uimp)<\/th>\n<td>4kV<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \uc804\uc555(AC)<\/th>\n<td>240 V<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \ub2e8\ub77d \uc804\ub958(Icn)<\/th>\n<td>6 kA<\/td>\n<\/tr>\n<tr>\n<th>\uc11c\uc9c0 \uc804\ub958 \uac15\ub3c4<\/th>\n<td>0.25 kA<\/td>\n<\/tr>\n<tr>\n<th>\ucd5c\ub300 \ucd1d \uc2a4\uc704\uce6d \uc6a9\ub7c9<\/th>\n<td>6 kA<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \uc808\uc5f0 \uc804\uc555<\/th>\n<td>250 V<\/td>\n<\/tr>\n<tr>\n<th>\uadf9\ub2f9 \uc5f4 \uc190\uc2e4<\/th>\n<td>3 W<\/td>\n<\/tr>\n<tr>\n<th>\ub2e8\ub77d \ubc31\uc5c5 \ud4e8\uc988(SCPD)<\/th>\n<td>100 A (gG)<\/td>\n<\/tr>\n<tr>\n<th>\uacfc\uc804\uc555 \ub4f1\uae09<\/th>\n<td>III<\/td>\n<\/tr>\n<tr>\n<th>\ud130\ubbf8\ub110<\/th>\n<td>\ub098\uc0ac\ud615, \uc0c1\ub2e8 \ubc0f \ud558\ub2e8(\ubd80\ud558 \ud68c\ub85c)<\/td>\n<\/tr>\n<tr>\n<th>\uc911\ub9bd \ub3c4\uccb4 \uc704\uce58<\/th>\n<td>\uc67c\ucabd\/\uc624\ub978\ucabd<\/td>\n<\/tr>\n<tr>\n<th>\ucd5c\ub300 \uc5f0\uacb0 \ucf00\uc774\ube14 \uae38\uc774<\/th>\n<td>70 m (DB to outer socket)<\/td>\n<\/tr>\n<tr>\n<th>\ud074\ub7a8\ud551 \uc601\uc5ed<\/th>\n<td>1-25 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th>\uc870\uc784 \ud1a0\ud06c<\/th>\n<td>2.0-2.4 Nm<\/td>\n<\/tr>\n<tr>\n<th>\uae30\uacc4\uc801 \ub0b4\uad6c\uc131<\/th>\n<td>\u2265 20,000\ud68c \uc774\uc0c1<\/td>\n<\/tr>\n<tr>\n<th>\uc804\uae30\uc801 \ub0b4\uad6c\uc131<\/th>\n<td>\u2265 4,000\ud68c \uc774\uc0c1<\/td>\n<\/tr>\n<tr>\n<th>\ubcf4\uad00\/\uc791\ub3d9 \uc628\ub3c4<\/th>\n<td>-35\u2103...+60\u2103 \/ -25\u2103...+40\u2103<\/td>\n<\/tr>\n<tr>\n<th>\ud558\uc6b0\uc9d5 \uc720\ud615 \/ \uc7ac\uc9c8<\/th>\n<td>\ubc30\uc804\ubc18 \ud558\uc6b0\uc9d5 \/ \uc5f4\uac00\uc18c\uc131 \ud50c\ub77c\uc2a4\ud2f1<\/td>\n<\/tr>\n<tr>\n<th>\ub9c8\uc6b4\ud305<\/th>\n<td>DIN \ub808\uc77c(35mm)<\/td>\n<\/tr>\n<tr>\n<th>\ubcf4\ud638 \ub4f1\uae09<\/th>\n<td>IP20(\uc124\uce58: IP40)<\/td>\n<\/tr>\n<tr>\n<th>\ud45c\uc900<\/th>\n<td>EN62606, EN61009-1<\/td>\n<\/tr>\n<tr>\n<th>\uc804\ub825 \uc81c\ud55c \uce74\ud14c\uace0\ub9ac<\/th>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th>\uc624\uc5fc\ub3c4(EN60664)<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>\uc778\uc99d<\/th>\n<td>UKCA, CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- Applications --><\/p>\n<h2>\uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/h2>\n<p>Fire protection for final circuits up to 40 A in residential, commercial and public buildings<br \/>\n(bedrooms, offices, hospitals, schools). Suitable for <strong>TN-S<\/strong> \ubc0f <strong>TN-C-S<\/strong> networks.<br \/>\nNot suitable for TN-C systems or circuits with smooth DC residual currents not equal to 50 Hz.<\/p>\n<p><!-- Certifications --><\/p>\n<h2>\uc778\uc99d<\/h2>\n<ul>\n<li>UKCA<\/li>\n<li>CE<\/li>\n<li>\ud45c\uc900 EN62606(AFDD), EN61009-1(RCBO)<\/li>\n<\/ul>\n<p><!-- FAQ --><\/p>\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<details>\n<summary>What is the difference between AFDD and RCCB?<\/summary>\n<p>AFDD detects series\/parallel arc faults to prevent fires; RCCB trips on residual (leakage) current. AFDD-1 integrates AFDD + MCB + RCCB in one device.<\/p>\n<\/details>\n<details>\n<summary>Can AFDD-1 be used in TN-C systems?<\/summary>\n<p>No. AFDD-1 is intended for TN-S and TN-C-S networks.<\/p>\n<\/details>\n<details>\n<summary>Which leakage types are detected?<\/summary>\n<p>Type A: sinusoidal AC and pulsating DC residual currents.<\/p>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"268\" data-end=\"366\">\n<p data-start=\"270\" data-end=\"366\">Arc-fault detection device (AFDD) with integrated overcurrent and residual current protection.<\/p>\n<\/li>\n<li data-start=\"367\" data-end=\"456\">\n<p data-start=\"369\" data-end=\"456\">Rated current range: <strong data-start=\"390\" data-end=\"400\">6A-40A<\/strong>\uc794\ub958 \uc804\ub958 \uc720\ud615 <strong data-start=\"424\" data-end=\"429\">A<\/strong>, tripping curve <strong data-start=\"446\" data-end=\"453\">B\/C<\/strong>.<\/p>\n<\/li>\n<li data-start=\"457\" data-end=\"531\">\n<p data-start=\"459\" data-end=\"531\">\ub2e4\uc74c \uc0ac\ud56d\uc744 \uc900\uc218\ud569\ub2c8\ub2e4. <strong data-start=\"473\" data-end=\"496\">EN62606 &amp; EN61009-1<\/strong>, short-circuit capacity <strong data-start=\"521\" data-end=\"528\">6kA<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":2441,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[33],"product_tag":[],"class_list":{"0":"post-1526","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-afdd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product\/1526","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/comments?post=1526"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media\/2441"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media?parent=1526"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_brand?post=1526"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_cat?post=1526"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_tag?post=1526"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}