{"id":1308,"date":"2025-09-09T15:22:52","date_gmt":"2025-09-09T15:22:52","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1308"},"modified":"2025-12-01T06:54:30","modified_gmt":"2025-12-01T06:54:30","slug":"type-1-2-surge-protective-device-2p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ko\/product\/type-1-2-surge-protective-device-2p\/","title":{"rendered":"\uc720\ud615 1+2 \uc11c\uc9c0 \ubcf4\ud638 \uc7a5\uce58 2P KYSPD-7T1+2-2P | Kuangya"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-7T1+2-2P is a two-pole <strong>type 1+2 surge protective device 2P<\/strong> for 230 V AC distribution systems. Combining Class I and Class II performance, this <strong>type 1+2 surge protective device 2P<\/strong> safely discharges lightning current impulses (10\/350 \u03bcs) and switching surges (8\/20 \u03bcs). It is designed for residential, commercial, and light industrial applications where both first- and second-stage protection are required in one device.<\/section>\n<section id=\"features\">\n<h3>\uc8fc\uc694 \uae30\ub2a5<\/h3>\n<ul>\n<li>Complies with IEC\/EN 61643-11, providing both Class I and Class II protection.<\/li>\n<li>Iimp 7 kA (10\/350 \u03bcs) per pole; In 20 kA (8\/20 \u03bcs); Imax 40 kA (8\/20 \u03bcs).<\/li>\n<li>Two-pole structure designed as a <strong>type 1+2 surge protective device 2P<\/strong> for compact boards.<\/li>\n<li>Uc 275 V AC; nominal operating voltage 230 V AC.<\/li>\n<li>\uc804\uc555 \ubcf4\ud638 \uc218\uc900(\uc704): \u2264 1.5kV.<\/li>\n<li>25ns \ubbf8\ub9cc\uc758 \ube60\ub978 \uc751\ub2f5 \uc2dc\uac04.<\/li>\n<li>Pluggable replaceable module with thermal disconnector and green\/red status window.<\/li>\n<li>Optional RC contacts for remote status indication.<\/li>\n<li>Housing UL94 V-0, IP20 (built-in); DIN 35 mm rail mount (EN 60715).<\/li>\n<li>Reliable two-pole <strong>type 1+2 surge protective device 2P<\/strong> for AC panels in lightning-prone areas.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\uc0ac\uc591<\/h3>\n<table>\n<thead>\n<tr>\n<th>\ub9e4\uac1c\ubcc0\uc218<\/th>\n<th>\uac00\uce58<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\uc81c\ud488 \ucf54\ub4dc<\/td>\n<td>KYSPD-7T1+2-2P<\/td>\n<\/tr>\n<tr>\n<td>\uce74\ud14c\uace0\ub9ac<\/td>\n<td>Type 1+2 Surge Protective Device 2P<\/td>\n<\/tr>\n<tr>\n<td>\uacf5\uce6d \uc2dc\uc2a4\ud15c \uc804\uc555<\/td>\n<td>230 V AC<\/td>\n<\/tr>\n<tr>\n<td>Max. \uc5f0\uc18d \uc791\ub3d9 \uc804\uc555(Uc)<\/td>\n<td>275 V AC<\/td>\n<\/tr>\n<tr>\n<td>\uc784\ud384\uc2a4 \ubc29\uc804 \uc804\ub958(Iimp, 10\/350 \u03bcs)<\/td>\n<td>\uadf9\ub2f9 7kA<\/td>\n<\/tr>\n<tr>\n<td>\uacf5\uce6d \ubc29\uc804 \uc804\ub958(In, 8\/20 \u03bcs)<\/td>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<td>\ucd5c\ub300. \ubc29\uc804 \uc804\ub958(\uc544\uc774\ub9e5\uc2a4, 8\/20 \u03bcs)<\/td>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<td>\uc804\uc555 \ubcf4\ud638 \uc218\uc900(\uc0c1\ud5a5)<\/td>\n<td>\u2264 1.5kV<\/td>\n<\/tr>\n<tr>\n<td>\uc751\ub2f5 \uc2dc\uac04<\/td>\n<td>&lt; 25ns<\/td>\n<\/tr>\n<tr>\n<td>\ubc31\uc5c5 \ud4e8\uc988(\ucd5c\ub300)<\/td>\n<td>125 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<td>\ub2e8\ub77d \uc804\ub958 \uc815\uaca9(ISCCR)<\/td>\n<td>25 kA<\/td>\n<\/tr>\n<tr>\n<td>\uc791\ub3d9 \uc628\ub3c4<\/td>\n<td>-40\u00b0C ... +70\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\ub9c8\uc6b4\ud305<\/td>\n<td>35mm DIN \ub808\uc77c<\/td>\n<\/tr>\n<tr>\n<td>\uc8fc\ud0dd<\/td>\n<td>\uc5f4\uac00\uc18c\uc131 \ud50c\ub77c\uc2a4\ud2f1 UL94 V-0<\/td>\n<\/tr>\n<tr>\n<td>\ubcf4\ud638 \ub4f1\uae09<\/td>\n<td>IP20(\ub0b4\uc7a5)<\/td>\n<\/tr>\n<tr>\n<td>\uc6d0\uaca9 \uc2e0\ud638<\/td>\n<td>RC \uc811\uc810(\uc635\uc158)<\/td>\n<\/tr>\n<tr>\n<td>\ud45c\uc900<\/td>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\uc774 <strong>type 1+2 surge protective device 2P<\/strong> \ub294 \ub099\ub8b0 \uc804\ub958 \ucc98\ub9ac\uc640 \uc11c\uc9c0 \uc804\uc555 \uc81c\ud55c \uae30\ub2a5\uc744 \ud558\ub098\uc758 \uc18c\ud615 \ubaa8\ub4c8\uc5d0 \ubaa8\ub450 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<\/section>\n<section id=\"wiring\">\n<h3>\ubc30\uc120 \ubc0f \uce58\uc218<\/h3>\n<ul>\n<li>\uc5f0\uacb0 \ub2e4\uc774\uc5b4\uadf8\ub7a8: <em>kyspd-7t1+2-2p-connection<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1311\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-wiring-diagram-283x300.png\" alt=\"type 1+2 surge protective device 2P wiring diagram\" width=\"396\" height=\"420\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-wiring-diagram-283x300.png 283w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-wiring-diagram-300x318.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-wiring-diagram.png 447w\" sizes=\"auto, (max-width: 396px) 100vw, 396px\" \/><\/li>\n<li>\uce58\uc218: <em>kyspd-7t1+2-2p-dimensions<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1310\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-dimension-300x298.png\" alt=\"type 1+2 surge protective device 2P dimensions\" width=\"403\" height=\"400\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-dimension-300x298.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-dimension-150x150.png 150w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-dimension-100x100.png 100w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-2P-dimension.png 394w\" sizes=\"auto, (max-width: 403px) 100vw, 403px\" \/><\/li>\n<\/ul>\n<\/section>\n<section id=\"apps\">\n<h3>\uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/h3>\n<ul>\n<li>Main distribution boards for residential and commercial use.<\/li>\n<li>First- and second-stage <strong>type 1+2 surge protective device 2P<\/strong> protection in one unit.<\/li>\n<li>Ideal for electrical systems exposed to frequent switching operations and lightning strikes.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h3>\n<details>\n<summary>Where should KYSPD-7T1+2-2P be installed?<\/summary>\n<p>It should be installed in distribution panels as a <strong>type 1+2 surge protective device 2P<\/strong>.<\/p>\n<\/details>\n<details>\n<summary>What surges does it protect against?<\/summary>\n<p>\uc774 <strong>type 1+2 surge protective device 2P<\/strong> protects against both lightning currents and switching surges.<\/p>\n<\/details>\n<details>\n<summary>Can it be used in residential systems?<\/summary>\n<p>Yes, this compact <strong>type 1+2 surge protective device 2P<\/strong> is suitable for residential, commercial, and light industrial boards.<\/p>\n<\/details>\n<details>\n<summary>\uc6d0\uaca9 \uc2dc\uadf8\ub110\ub9c1\uc744 \uc9c0\uc6d0\ud558\ub098\uc694?<\/summary>\n<p>Yes, RC contacts can be added for remote monitoring of the <strong>type 1+2 surge protective device 2P<\/strong>.<\/p>\n<\/details>\n<details>\n<summary>\uc5b4\ub5a4 \uae30\uc900\uc744 \ucda9\uc871\ud558\ub098\uc694?<\/summary>\n<p>AC \uc11c\uc9c0 \ubcf4\ud638 \uc7a5\uce58\uc6a9 IEC\/EN 61643-11.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta\"><a href=\"\/ko\/contact-us\/\">\uacac\uc801 \ubc1b\uae30<\/a> - \uad00\ub828 \uc81c\ud488: <a href=\"\/ko\/ac-mcb\/\">AC MCB<\/a>, <a href=\"\/ko\/manual-transfer-switch\/\">\uc218\ub3d9 \uc804\uc1a1 \uc2a4\uc704\uce58<\/a><\/section>","protected":false},"excerpt":{"rendered":"<ul data-start=\"243\" data-end=\"496\">\n<li data-start=\"243\" data-end=\"334\">\n<p data-start=\"245\" data-end=\"334\">Two-pole <strong data-start=\"254\" data-end=\"293\">type 1+2 surge protective device 2P<\/strong> for residential and commercial panels.<\/p>\n<\/li>\n<li data-start=\"335\" data-end=\"405\">\n<p data-start=\"337\" data-end=\"405\">Iimp 7 kA (10\/350 \u03bcs) per pole, In 20 kA, Imax 40 kA; Uc 275 V AC.<\/p>\n<\/li>\n<li data-start=\"406\" data-end=\"496\">\n<p data-start=\"408\" data-end=\"496\">Compact pluggable module with thermal disconnector, LED indicator, optional RC contacts.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1580,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1308","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product\/1308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/comments?post=1308"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media\/1580"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media?parent=1308"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_brand?post=1308"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_cat?post=1308"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_tag?post=1308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}