{"id":1184,"date":"2025-09-07T07:05:46","date_gmt":"2025-09-07T07:05:46","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1184"},"modified":"2025-09-07T07:32:42","modified_gmt":"2025-09-07T07:32:42","slug":"manual-transfer-switch-for-generator-63a-2p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ko\/product\/manual-transfer-switch-for-generator-63a-2p\/","title":{"rendered":"KYMTS-63A 2P \uc218\ub3d9 \ud2b8\ub79c\uc2a4\ud37c \uc2a4\uc704\uce58"},"content":{"rendered":"<section id=\"overview-63a-2p\">\n<h2>\uac1c\uc694<\/h2>\n<p>\uadf8\ub9ac\uace0 <strong>\ubc1c\uc804\uae30\uc6a9 \uc218\ub3d9 \uc804\uc1a1 \uc2a4\uc704\uce58<\/strong> (KYMTS-63A 2P) is designed for single-phase AC systems where both line and neutral must be switched for safe and reliable changeover. It allows manual I\u20130\u2013II switching between utility, generator, or PV inverter, preventing back-feeding and ensuring supply continuity.<\/p>\n<p>For more models and selection guidance, see the <a href=\"\/ko\/manual-transfer-switch\/\">\uc218\ub3d9 \uc804\uc1a1 \uc2a4\uc704\uce58<\/a> landing page. In PV\/ESS systems, the KYMTS-63A 2P can be combined with <a href=\"\/ko\/pv-combiner-box\/\">PV \ucef4\ubc14\uc774\ub108 \ubc15\uc2a4<\/a>, <a href=\"\/ko\/dc-breaker\/\">\ud68c\ub85c \ucc28\ub2e8\uae30<\/a>\ubc0f <a href=\"\/ko\/dc-fuse\/\">DC \ud4e8\uc988<\/a>. \ucc38\uc870 <a href=\"https:\/\/www.iec.ch\/\" target=\"_blank\" rel=\"noopener\">IEC<\/a> \ud45c\uc900 \ubc0f <a href=\"https:\/\/ec.europa.eu\/growth\/single-market\/ce-marking\/\" target=\"_blank\" rel=\"noopener\">CE \ub9c8\ud06c<\/a> requirements for compliance.<\/p>\n<\/section>\n<section id=\"features-63a-2p\">\n<h2>\uc8fc\uc694 \uae30\ub2a5<\/h2>\n<ul>\n<li><strong>63A, 2P<\/strong> design switches both line and neutral conductors.<\/li>\n<li>\uc9c0\uc6b0\uae30 <strong>I \/ 0 \/ II<\/strong> handle positions for safe and intuitive operation.<\/li>\n<li><strong>\uad6c\ub9ac \uc811\uc810<\/strong> ensure high conductivity and low power loss.<\/li>\n<li>\ucef4\ud329\ud2b8\ud55c \ubcf8\uccb4 \uc9c0\uc9c0\ub300 <strong>DIN \ub808\uc77c\/\ud328\ub110<\/strong> \uc124\uce58.<\/li>\n<li>\uc774\uc0c1\uc801\uc778 \ub300\uc0c1 <strong>\ubc1c\uc804\uae30 \uc804\ud658<\/strong> and PV inverter transfer.<\/li>\n<li>\ub2e4\uc74c \uc0ac\ud56d\uc744 \uc900\uc218\ud569\ub2c8\ub2e4. <strong>IEC 60947-3<\/strong> \uc2a4\uc704\uce58-\ub2e8\uc790 \ud45c\uc900.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs-63a-2p\">\n<h2>\uc0ac\uc591<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\ubaa8\ub378<\/th>\n<td>KYMTS-63A 2P<\/td>\n<\/tr>\n<tr>\n<th>\ud3f4<\/th>\n<td>2P(L+N)<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \uc804\ub958(In)<\/th>\n<td>63A<\/td>\n<\/tr>\n<tr>\n<th>\uc815\uaca9 \uc791\ub3d9 \uc804\uc555(Ue)<\/th>\n<td>240V AC<\/td>\n<\/tr>\n<tr>\n<th>\ube48\ub3c4<\/th>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<th>\uc808\uc5f0 \uc804\uc555(Ui)<\/th>\n<td>690V<\/td>\n<\/tr>\n<tr>\n<th>\ub9c8\uc6b4\ud305<\/th>\n<td>DIN \ub808\uc77c \/ \ud328\ub110<\/td>\n<\/tr>\n<tr>\n<th>\ucc38\uc870 \ud45c\uc900<\/th>\n<td>IEC 60947-3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring-63a-2p\">\n<h2>\ubc30\uc120 \ubc0f \uce58\uc218<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1172\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-diagram-300x200.png\" alt=\"KUMTS-63-\ub2e4\uc774\uc5b4\uadf8\ub7a8\" width=\"558\" height=\"372\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-diagram-300x200.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-diagram-600x399.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-diagram.png 625w\" sizes=\"auto, (max-width: 558px) 100vw, 558px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1173\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-dimension-300x181.png\" alt=\"KUMTS-63-\ucc28\uc6d0\" width=\"553\" height=\"334\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-dimension-300x181.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-dimension-768x463.png 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-dimension-600x362.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/kumts-63-dimension.png 918w\" sizes=\"auto, (max-width: 553px) 100vw, 553px\" \/><\/p>\n<\/section>\n<section id=\"apps-63a-2p\">\n<h2>\uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/h2>\n<ul>\n<li>Residential generator backup requiring L+N switching<\/li>\n<li>\ub2e8\uc0c1 <strong>\ud0dc\uc591\uad11 \uc778\ubc84\ud130<\/strong> source changeover<\/li>\n<li>Shops and small commercial loads with dual-source supply<\/li>\n<li>ESS auxiliary circuits and microgrid feeders<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq-63a-2p\">\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<details>\n<summary>What is a manual transfer switch for generator?<\/summary>\n<p>It is a device that safely switches a single-phase 63A load between utility and generator\/PV inverter, isolating both line and neutral conductors.<\/p>\n<\/details>\n<details>\n<summary>When should I choose a 2P switch instead of 1P?<\/summary>\n<p>Use a 2P switch when both line and neutral must be isolated during source transfer for enhanced safety and compliance.<\/p>\n<\/details>\n<details>\n<summary>Where can I compare other models?<\/summary>\n<p>\ubc29\ubb38\ud558\uae30 <a href=\"\/ko\/manual-transfer-switch\/\">\uc218\ub3d9 \uc804\uc1a1 \uc2a4\uc704\uce58<\/a> landing page for full 1P\/2P\/3P\/4P options.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta-63a-2p\">\n<h2>\uacac\uc801\uc774 \ud544\uc694\ud558\uc2e0\uac00\uc694?<\/h2>\n<p>Looking for a <strong>\ubc1c\uc804\uae30\uc6a9 \uc218\ub3d9 \uc804\uc1a1 \uc2a4\uc704\uce58<\/strong>? <a href=\"\/ko\/contact-us\/\">\ubb38\uc758\ud558\uae30<\/a> today for datasheets, technical support, and pricing.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul data-start=\"249\" data-end=\"545\">\n<li data-start=\"249\" data-end=\"367\">\n<p data-start=\"251\" data-end=\"367\">\uadf8\ub9ac\uace0 <strong data-start=\"255\" data-end=\"295\">\ubc1c\uc804\uae30\uc6a9 \uc218\ub3d9 \uc804\uc1a1 \uc2a4\uc704\uce58<\/strong> 63A 2P safely changes over line + neutral in single-phase AC systems.<\/p>\n<\/li>\n<li data-start=\"368\" data-end=\"459\">\n<p data-start=\"370\" data-end=\"459\">\uc778\uccb4\uacf5\ud559\uc801 I-0-II \ud578\ub4e4, \uad6c\ub9ac \uc811\uc810, DIN \ub808\uc77c \ub610\ub294 \ud328\ub110 \uc7a5\ucc29\uc774 \uac00\ub2a5\ud55c \ucef4\ud329\ud2b8\ud55c \ubcf8\uccb4.<\/p>\n<\/li>\n<li data-start=\"460\" data-end=\"545\">\n<p data-start=\"462\" data-end=\"545\">IEC 60947-3 compliant, suitable for residential backup, PV, and ESS applications.<\/p>\n<\/li>\n<\/ul>\n<div class=\"contain-inline-size rounded-2xl relative bg-token-sidebar-surface-primary\">\n<div class=\"sticky top-9\">\n<div class=\"absolute end-0 bottom-0 flex h-9 items-center pe-2\">\n<div class=\"bg-token-bg-elevated-secondary text-token-text-secondary flex items-center gap-4 rounded-sm px-2 font-sans text-xs\"><\/div>\n<\/div>\n<\/div>\n<div class=\"overflow-y-auto p-4\" dir=\"ltr\"><\/div>\n<\/div>","protected":false},"featured_media":1181,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":{"0":"post-1184","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-manual-transfer-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product\/1184","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/comments?post=1184"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/media?parent=1184"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_brand?post=1184"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_cat?post=1184"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ko\/wp-json\/wp\/v2\/product_tag?post=1184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}