{"id":3613,"date":"2026-06-11T10:19:09","date_gmt":"2026-06-11T02:19:09","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=3613"},"modified":"2026-06-11T14:47:12","modified_gmt":"2026-06-11T06:47:12","slug":"hot-aerosol-fire-extinguishing-device-30g-automatic","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ja\/product\/hot-aerosol-fire-extinguishing-device-30g-automatic\/","title":{"rendered":"Cabinet Automatic Fire Extinguishing Device (Hot Aerosol) &#8211; 30g for Power Distribution Cabinets"},"content":{"rendered":"<h1 data-section-id=\"utw89p\" data-start=\"640\" data-end=\"684\">30g Heat Aerosol Fire Extinguishing Device<\/h1>\n<p data-start=\"686\" data-end=\"987\">Electrical faults are among the leading causes of fires in distribution boards, control panels, battery cabinets, and server enclosures. The 30g Heat Aerosol Fire Extinguishing Device provides an automatic, self-contained fire suppression solution designed specifically for enclosed electrical spaces.<\/p>\n<p data-start=\"989\" data-end=\"1347\">When the surrounding temperature reaches approximately 170\u00b0C or comes into direct contact with flames, the device automatically activates and releases a condensed aerosol extinguishing agent that suppresses the fire within seconds. No external power supply, control panel, piping system, or manual operation is required.<\/p>\n<hr data-start=\"1349\" data-end=\"1352\" \/>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"1354\" data-end=\"1369\">\u4e3b\u306a\u7279\u5fb4<\/h2>\n<h3 data-section-id=\"bfsv4j\" data-start=\"1371\" data-end=\"1413\">Automatic Fire Detection &amp; Suppression<\/h3>\n<p data-start=\"1415\" data-end=\"1675\">The built-in thermal activation system continuously monitors temperature. Once a fire begins inside the enclosure, the device automatically releases aerosol extinguishing particles to stop combustion at its earliest stage.<\/p>\n<h3 data-section-id=\"p4tbxo\" data-start=\"1677\" data-end=\"1707\">No External Power Required<\/h3>\n<p data-start=\"1709\" data-end=\"1899\">Unlike traditional fire suppression systems, this unit operates independently and requires no electrical wiring, batteries, sensors, or control modules.<\/p>\n<h3 data-section-id=\"1d24pbc\" data-start=\"1901\" data-end=\"1934\">Safe for Electrical Equipment<\/h3>\n<p data-start=\"1936\" data-end=\"2181\">The aerosol agent leaves minimal residue and does not damage electrical components, making it suitable for sensitive equipment including PLCs, circuit breakers, communication devices, batteries, and servers.<\/p>\n<h3 data-section-id=\"1gu1vxv\" data-start=\"2183\" data-end=\"2201\">\u30b3\u30f3\u30d1\u30af\u30c8\u8a2d\u8a08<\/h3>\n<p data-start=\"2203\" data-end=\"2247\">Its compact size allows installation inside:<\/p>\n<ul data-start=\"2249\" data-end=\"2478\">\n<li data-section-id=\"9oaavv\" data-start=\"2249\" data-end=\"2270\">\u914d\u96fb\u76e4<\/li>\n<li data-section-id=\"8jfe1w\" data-start=\"2271\" data-end=\"2300\">Electrical control cabinets<\/li>\n<li data-section-id=\"1q5623y\" data-start=\"2301\" data-end=\"2320\">Switchgear panels<\/li>\n<li data-section-id=\"mh38n9\" data-start=\"2321\" data-end=\"2335\">Server racks<\/li>\n<li data-section-id=\"rv5wvo\" data-start=\"2336\" data-end=\"2354\">\u901a\u4fe1\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8<\/li>\n<li data-section-id=\"2oza99\" data-start=\"2355\" data-end=\"2377\">EV\u5145\u96fb\u30b9\u30c6\u30fc\u30b7\u30e7\u30f3<\/li>\n<li data-section-id=\"1i6as6z\" data-start=\"2378\" data-end=\"2400\">\u30bd\u30fc\u30e9\u30fc\u30b3\u30f3\u30d0\u30a4\u30ca\u30fc\u30dc\u30c3\u30af\u30b9<\/li>\n<li data-section-id=\"17kcamr\" data-start=\"2401\" data-end=\"2478\">Battery energy storage systems (BESS)<\/li>\n<\/ul>\n<h3 data-section-id=\"yxx5cn\" data-start=\"2480\" data-end=\"2510\">Maintenance-Free Operation<\/h3>\n<p data-start=\"2512\" data-end=\"2656\">The device offers a service life of up to 10 years and requires virtually no maintenance during operation.<\/p>\n<h3 data-section-id=\"1tnbjpo\" data-start=\"2658\" data-end=\"2686\">Environmentally Friendly<\/h3>\n<p data-start=\"2688\" data-end=\"2858\">The condensed aerosol technology contains no ozone-depleting substances and provides a clean, sustainable fire suppression solution.<\/p>\n<hr data-start=\"2860\" data-end=\"2863\" \/>\n<h1 data-section-id=\"1qumg9l\" data-start=\"2865\" data-end=\"2879\">\u4ed5\u7d44\u307f<\/h1>\n<p data-start=\"2881\" data-end=\"3043\">The Heat Aerosol Fire Extinguishing Device contains a specially formulated solid aerosol compound consisting primarily of strontium nitrate and potassium nitrate.<\/p>\n<p data-start=\"3045\" data-end=\"3060\">When activated:<\/p>\n<ol data-start=\"3062\" data-end=\"3415\">\n<li data-section-id=\"5vlisi\" data-start=\"3062\" data-end=\"3107\">The thermal trigger detects abnormal heat.<\/li>\n<li data-section-id=\"klsa6d\" data-start=\"3108\" data-end=\"3174\">The aerosol compound undergoes an oxidation-reduction reaction.<\/li>\n<li data-section-id=\"10em93o\" data-start=\"3175\" data-end=\"3220\">Ultra-fine aerosol particles are released.<\/li>\n<li data-section-id=\"1jh6twk\" data-start=\"3221\" data-end=\"3278\">Active free radicals within the flame are neutralized.<\/li>\n<li data-section-id=\"xoki2w\" data-start=\"3279\" data-end=\"3327\">The combustion chain reaction is interrupted.<\/li>\n<li data-section-id=\"4sjp2b\" data-start=\"3328\" data-end=\"3415\">The fire is extinguished before it can spread.<\/li>\n<\/ol>\n<p data-start=\"3417\" data-end=\"3629\">Unlike water, foam, or powder extinguishers, the aerosol particles can penetrate difficult-to-reach areas inside enclosed cabinets, providing total flooding fire suppression.<\/p>\n<hr data-start=\"3631\" data-end=\"3634\" \/>\n<h1 data-section-id=\"zjxypn\" data-start=\"3636\" data-end=\"3662\">\u6280\u8853\u4ed5\u69d8<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3664\" data-end=\"4310\">\n<thead data-start=\"3664\" data-end=\"3693\">\n<tr data-start=\"3664\" data-end=\"3693\">\n<th class=\"last:pe-10\" data-start=\"3664\" data-end=\"3676\" data-col-size=\"sm\">\u30d1\u30e9\u30e1\u30fc\u30bf<\/th>\n<th class=\"last:pe-10\" data-start=\"3676\" data-end=\"3693\" data-col-size=\"sm\">\u4ed5\u69d8<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3723\" data-end=\"4310\">\n<tr data-start=\"3723\" data-end=\"3780\">\n<td data-start=\"3723\" data-end=\"3738\" data-col-size=\"sm\">Product Name<\/td>\n<td data-col-size=\"sm\" data-start=\"3738\" data-end=\"3780\">Heat Aerosol Fire Extinguishing Device<\/td>\n<\/tr>\n<tr data-start=\"3781\" data-end=\"3803\">\n<td data-start=\"3781\" data-end=\"3796\" data-col-size=\"sm\">Agent Weight<\/td>\n<td data-col-size=\"sm\" data-start=\"3796\" data-end=\"3803\">30g<\/td>\n<\/tr>\n<tr data-start=\"3804\" data-end=\"3833\">\n<td data-start=\"3804\" data-end=\"3823\" data-col-size=\"sm\">Protected Volume<\/td>\n<td data-col-size=\"sm\" data-start=\"3823\" data-end=\"3833\">\u22640.3m\u00b3<\/td>\n<\/tr>\n<tr data-start=\"3834\" data-end=\"3876\">\n<td data-start=\"3834\" data-end=\"3854\" data-col-size=\"sm\">\u8d77\u52d5\u65b9\u6cd5<\/td>\n<td data-col-size=\"sm\" data-start=\"3854\" data-end=\"3876\">Thermal Activation<\/td>\n<\/tr>\n<tr data-start=\"3877\" data-end=\"3917\">\n<td data-start=\"3877\" data-end=\"3902\" data-col-size=\"sm\">Activation Temperature<\/td>\n<td data-col-size=\"sm\" data-start=\"3902\" data-end=\"3917\">170\u00b0C \u00b115\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"3918\" data-end=\"3953\">\n<td data-start=\"3918\" data-end=\"3942\" data-col-size=\"sm\">Extinguishing Density<\/td>\n<td data-col-size=\"sm\" data-start=\"3942\" data-end=\"3953\">100g\/m\u00b3<\/td>\n<\/tr>\n<tr data-start=\"3954\" data-end=\"3996\">\n<td data-start=\"3954\" data-end=\"3978\" data-col-size=\"sm\">\u52d5\u4f5c\u6e29\u5ea6<\/td>\n<td data-col-size=\"sm\" data-start=\"3978\" data-end=\"3996\">-50\u00b0C to +90\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"3997\" data-end=\"4024\">\n<td data-start=\"3997\" data-end=\"4012\" data-col-size=\"sm\">\u8010\u7528\u5e74\u6570<\/td>\n<td data-col-size=\"sm\" data-start=\"4012\" data-end=\"4024\">10 Years<\/td>\n<\/tr>\n<tr data-start=\"4025\" data-end=\"4065\">\n<td data-start=\"4025\" data-end=\"4055\" data-col-size=\"sm\">Housing Surface Temperature<\/td>\n<td data-col-size=\"sm\" data-start=\"4055\" data-end=\"4065\">\u2264200\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"4066\" data-end=\"4115\">\n<td data-start=\"4066\" data-end=\"4089\" data-col-size=\"sm\">Oxidizer Composition<\/td>\n<td data-col-size=\"sm\" data-start=\"4089\" data-end=\"4115\">Sr(NO\u2083)\u2082 60%, KNO\u2083 20%<\/td>\n<\/tr>\n<tr data-start=\"4116\" data-end=\"4160\">\n<td data-start=\"4116\" data-end=\"4131\" data-col-size=\"sm\">Fire Classes<\/td>\n<td data-col-size=\"sm\" data-start=\"4131\" data-end=\"4160\">A, B, C, Electrical Fires<\/td>\n<\/tr>\n<tr data-start=\"4161\" data-end=\"4215\">\n<td data-start=\"4161\" data-end=\"4183\" data-col-size=\"sm\">\u8a2d\u7f6e\u65b9\u6cd5<\/td>\n<td data-col-size=\"sm\" data-start=\"4183\" data-end=\"4215\">Adhesive Mounting \/ DIN Rail<\/td>\n<\/tr>\n<tr data-start=\"4216\" data-end=\"4310\">\n<td data-start=\"4216\" data-end=\"4232\" data-col-size=\"sm\">\u8a8d\u8a3c<\/td>\n<td data-col-size=\"sm\" data-start=\"4232\" data-end=\"4269\">EN15276-1:2019, EN15276-2:2019, CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"4312\" data-end=\"4315\" \/>\n<h1 data-section-id=\"bazihh\" data-start=\"4317\" data-end=\"4339\">\u4ee3\u8868\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h1>\n<h2 data-section-id=\"1apr29g\" data-start=\"4341\" data-end=\"4376\">Electrical Distribution Cabinets<\/h2>\n<p data-start=\"4378\" data-end=\"4484\">Protect low-voltage and medium-voltage distribution panels from short circuits, overloads, and arc faults.<\/p>\n<h2 data-section-id=\"uegzfk\" data-start=\"4486\" data-end=\"4514\">Industrial Control Panels<\/h2>\n<p data-start=\"4516\" data-end=\"4591\">Safeguard PLC cabinets, automation systems, and machine control enclosures.<\/p>\n<h2 data-section-id=\"179ti5f\" data-start=\"4593\" data-end=\"4633\">\u84c4\u96fb\u6c60\u30b7\u30b9\u30c6\u30e0\uff08BESS\uff09<\/h2>\n<p data-start=\"4635\" data-end=\"4715\">Provide automatic fire suppression for lithium battery cabinets and ESS systems.<\/p>\n<h2 data-section-id=\"1gmekwf\" data-start=\"4717\" data-end=\"4739\">Solar Power Systems<\/h2>\n<p data-start=\"4741\" data-end=\"4817\">Ideal for photovoltaic combiner boxes, inverter cabinets, and DC switchgear.<\/p>\n<h2 data-section-id=\"gl6wbk\" data-start=\"4819\" data-end=\"4842\">EV\u5145\u96fb\u30b9\u30c6\u30fc\u30b7\u30e7\u30f3<\/h2>\n<p data-start=\"4844\" data-end=\"4933\">Protect charging piles and electrical compartments from overheating and electrical fires.<\/p>\n<h2 data-section-id=\"1gqvzh6\" data-start=\"4935\" data-end=\"4963\">Server &amp; Telecom Cabinets<\/h2>\n<p data-start=\"4965\" data-end=\"5083\">Prevent costly downtime and equipment loss caused by electrical cabinet fires.<\/p>\n<hr data-start=\"5085\" data-end=\"5088\" \/>\n<h1 data-section-id=\"13eavk0\" data-start=\"5090\" data-end=\"5110\">\u30a4\u30f3\u30b9\u30c8\u30ec\u30fc\u30b7\u30e7\u30f3\u30fb\u30ac\u30a4\u30c9<\/h1>\n<h3 data-section-id=\"qpa9p2\" data-start=\"5112\" data-end=\"5149\">Recommended Installation Position<\/h3>\n<p data-start=\"5151\" data-end=\"5273\">Install the device at the top section of the enclosure where heat naturally accumulates during the early stages of a fire.<\/p>\n<h3 data-section-id=\"1g6bg6u\" data-start=\"5275\" data-end=\"5299\">Installation Methods<\/h3>\n<ul data-start=\"5301\" data-end=\"5370\">\n<li data-section-id=\"1t4jyau\" data-start=\"5301\" data-end=\"5327\">3M VHB Adhesive Mounting<\/li>\n<li data-section-id=\"c4vjg0\" data-start=\"5328\" data-end=\"5347\">DIN\u30ec\u30fc\u30eb\u30de\u30a6\u30f3\u30c8<\/li>\n<li data-section-id=\"q0dh6k\" data-start=\"5348\" data-end=\"5370\">Bracket Installation<\/li>\n<\/ul>\n<h3 data-section-id=\"q1kyx9\" data-start=\"5372\" data-end=\"5398\">Thermal Wire Placement<\/h3>\n<p data-start=\"5400\" data-end=\"5446\">The heat-sensitive wire should be routed near:<\/p>\n<ul data-start=\"5448\" data-end=\"5538\">\n<li data-section-id=\"17mldfy\" data-start=\"5448\" data-end=\"5457\">Busbars<\/li>\n<li data-section-id=\"wgbb28\" data-start=\"5458\" data-end=\"5476\">\u914d\u7dda\u7528\u906e\u65ad\u5668\uff08MCB\/MCCB\uff09<\/li>\n<li data-section-id=\"7ferkm\" data-start=\"5477\" data-end=\"5494\">Cable terminals<\/li>\n<li data-section-id=\"36bb3g\" data-start=\"5495\" data-end=\"5512\">\u30d0\u30c3\u30c6\u30ea\u30fc\u30e2\u30b8\u30e5\u30fc\u30eb<\/li>\n<li data-section-id=\"11xrc2m\" data-start=\"5513\" data-end=\"5538\">High-current components<\/li>\n<\/ul>\n<p data-start=\"5540\" data-end=\"5658\">This ensures the fastest possible activation during abnormal temperature rise.<\/p>\n<hr data-start=\"5660\" data-end=\"5663\" \/>\n<h1 data-section-id=\"1sq9v1s\" data-start=\"5665\" data-end=\"5710\">Advantages Over Traditional Fire Protection<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"5712\" data-end=\"6088\">\n<thead data-start=\"5712\" data-end=\"5782\">\n<tr data-start=\"5712\" data-end=\"5782\">\n<th class=\"last:pe-10\" data-start=\"5712\" data-end=\"5722\" data-col-size=\"sm\">\u7279\u5fb4<\/th>\n<th class=\"last:pe-10\" data-start=\"5722\" data-end=\"5744\" data-col-size=\"sm\">Heat Aerosol Device<\/th>\n<th class=\"last:pe-10\" data-start=\"5744\" data-end=\"5766\" data-col-size=\"sm\">Powder Extinguisher<\/th>\n<th class=\"last:pe-10\" data-start=\"5766\" data-end=\"5782\" data-col-size=\"sm\">Water System<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"5850\" data-end=\"6088\">\n<tr data-start=\"5850\" data-end=\"5885\">\n<td data-start=\"5850\" data-end=\"5872\" data-col-size=\"sm\">Automatic Operation<\/td>\n<td data-col-size=\"sm\" data-start=\"5872\" data-end=\"5876\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"5876\" data-end=\"5880\">\u2718<\/td>\n<td data-col-size=\"sm\" data-start=\"5880\" data-end=\"5885\">\u2714<\/td>\n<\/tr>\n<tr data-start=\"5886\" data-end=\"5919\">\n<td data-start=\"5886\" data-end=\"5906\" data-col-size=\"sm\">No External Power<\/td>\n<td data-col-size=\"sm\" data-start=\"5906\" data-end=\"5910\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"5910\" data-end=\"5914\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"5914\" data-end=\"5919\">\u2718<\/td>\n<\/tr>\n<tr data-start=\"5920\" data-end=\"5956\">\n<td data-start=\"5920\" data-end=\"5943\" data-col-size=\"sm\">Cabinet Installation<\/td>\n<td data-col-size=\"sm\" data-start=\"5943\" data-end=\"5947\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"5947\" data-end=\"5951\">\u2718<\/td>\n<td data-col-size=\"sm\" data-start=\"5951\" data-end=\"5956\">\u2718<\/td>\n<\/tr>\n<tr data-start=\"5957\" data-end=\"5986\">\n<td data-start=\"5957\" data-end=\"5973\" data-col-size=\"sm\">\u8fc5\u901f\u306a\u5bfe\u5fdc<\/td>\n<td data-col-size=\"sm\" data-start=\"5973\" data-end=\"5977\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"5977\" data-end=\"5981\">\u2718<\/td>\n<td data-col-size=\"sm\" data-start=\"5981\" data-end=\"5986\">\u2714<\/td>\n<\/tr>\n<tr data-start=\"5987\" data-end=\"6027\">\n<td data-start=\"5987\" data-end=\"6014\" data-col-size=\"sm\">Suitable for Electronics<\/td>\n<td data-col-size=\"sm\" data-start=\"6014\" data-end=\"6018\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"6018\" data-end=\"6022\">\u2718<\/td>\n<td data-col-size=\"sm\" data-start=\"6022\" data-end=\"6027\">\u2718<\/td>\n<\/tr>\n<tr data-start=\"6028\" data-end=\"6059\">\n<td data-start=\"6028\" data-end=\"6046\" data-col-size=\"sm\">Low Maintenance<\/td>\n<td data-col-size=\"sm\" data-start=\"6046\" data-end=\"6050\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"6050\" data-end=\"6054\">\u2718<\/td>\n<td data-col-size=\"sm\" data-start=\"6054\" data-end=\"6059\">\u2718<\/td>\n<\/tr>\n<tr data-start=\"6060\" data-end=\"6088\">\n<td data-start=\"6060\" data-end=\"6075\" data-col-size=\"sm\">\u7701\u30b9\u30da\u30fc\u30b9<\/td>\n<td data-col-size=\"sm\" data-start=\"6075\" data-end=\"6079\">\u2714<\/td>\n<td data-col-size=\"sm\" data-start=\"6079\" data-end=\"6083\">\u2718<\/td>\n<td data-col-size=\"sm\" data-start=\"6083\" data-end=\"6088\">\u2718<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"6090\" data-end=\"6093\" \/>\n<h1 data-section-id=\"1hk6r85\" data-start=\"6095\" data-end=\"6151\">Why Choose Our Heat Aerosol Fire Extinguishing Device?<\/h1>\n<ul data-start=\"6153\" data-end=\"6415\">\n<li data-section-id=\"s9j1tf\" data-start=\"6153\" data-end=\"6172\">EN15276 Certified<\/li>\n<li data-section-id=\"5w8xcg\" data-start=\"6173\" data-end=\"6195\">10-Year Service Life<\/li>\n<li data-section-id=\"15keuay\" data-start=\"6196\" data-end=\"6226\">Automatic Thermal Activation<\/li>\n<li data-section-id=\"cmmneq\" data-start=\"6227\" data-end=\"6255\">No External Power Required<\/li>\n<li data-section-id=\"ob2hf4\" data-start=\"6256\" data-end=\"6293\">Compact Design for Small Enclosures<\/li>\n<li data-section-id=\"1ceuv49\" data-start=\"6294\" data-end=\"6317\">Fast Fire Suppression<\/li>\n<li data-section-id=\"1v2ozeu\" data-start=\"6318\" data-end=\"6349\">Safe for Electrical Equipment<\/li>\n<li data-section-id=\"17xfrh6\" data-start=\"6350\" data-end=\"6369\">\u7c21\u5358\u306a\u53d6\u308a\u4ed8\u3051<\/li>\n<li data-section-id=\"1hnxz2u\" data-start=\"6370\" data-end=\"6391\">OEM &amp; ODM Available<\/li>\n<li data-section-id=\"wkeg88\" data-start=\"6392\" data-end=\"6415\">Global Export Support<\/li>\n<\/ul>\n<hr data-start=\"6417\" data-end=\"6420\" \/>\n<h1 data-section-id=\"hkd5a4\" data-start=\"6422\" data-end=\"6450\">\u3088\u304f\u3042\u308b\u8cea\u554f<\/h1>\n<h3 data-section-id=\"1p1xe1t\" data-start=\"6452\" data-end=\"6493\">What volume can a 30g device protect?<\/h3>\n<p data-start=\"6495\" data-end=\"6617\">The recommended protection volume is up to 0.3 cubic meters in a closed enclosure.<\/p>\n<h3 data-section-id=\"5m8rir\" data-start=\"6619\" data-end=\"6651\">Does it require electricity?<\/h3>\n<p data-start=\"6653\" data-end=\"6799\">No. The device is completely self-contained and activates automatically when exposed to high temperatures.<\/p>\n<h3 data-section-id=\"19bu8md\" data-start=\"6801\" data-end=\"6843\">What types of fires can it extinguish?<\/h3>\n<p data-start=\"6845\" data-end=\"7007\">It is suitable for Class A, B, C, and electrical fires commonly found inside electrical cabinets and equipment enclosures.<\/p>\n<h3 data-section-id=\"1i7m0p5\" data-start=\"7009\" data-end=\"7035\">How long does it last?<\/h3>\n<p data-start=\"7037\" data-end=\"7155\">The expected service life is up to 10 years under normal operating conditions.<\/p>","protected":false},"excerpt":{"rendered":"<p>The device adopts a red shell design and is equipped with a thermal starting line, which is suitable for fire protection of electrical cabinets with a space of 0.3 cubic meters.<\/p>","protected":false},"featured_media":3625,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[60],"product_tag":[],"class_list":["post-3613","product","type-product","status-publish","has-post-thumbnail","product_cat-dc-cabinet-automatic-fire-extinguishing-device-hot-aerosol-30g-for-power-distribution-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product\/3613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/comments?post=3613"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media\/3625"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media?parent=3613"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_brand?post=3613"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_cat?post=3613"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_tag?post=3613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}