{"id":1574,"date":"2025-09-16T07:47:16","date_gmt":"2025-09-16T07:47:16","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1574"},"modified":"2025-09-22T09:12:38","modified_gmt":"2025-09-22T09:12:38","slug":"%e3%82%bf%e3%82%a4%e3%83%97f-rccb-vkl11f","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ja\/product\/type-f-rccb-vkl11f\/","title":{"rendered":"RCCB VKL11F - \u6b8b\u7559\u96fb\u6d41\u30d6\u30ec\u30fc\u30ab"},"content":{"rendered":"<div class=\"product-description\">\n<h2>\u6982\u8981<\/h2>\n<p>The VKL11F <strong>\u30bf\u30a4\u30d7f rccb<\/strong> detects earth leakage including mixed-frequency components that commonly<br \/>\noccur with inverters, VFD-driven motors, and UPS equipment. It disconnects the circuit when residual current<br \/>\nexceeds the set threshold to protect people and installations against electric shock and fire hazards.<br \/>\nAvailable as 2P (single-phase) and 4P (three-phase).<\/p>\n<h2>\u4e3b\u306a\u7279\u5fb4<\/h2>\n<ul>\n<li>\u30dd\u30fc\u30eb\uff1a <strong>2P \/ 4P<\/strong><\/li>\n<li>\u5b9a\u683c\u96fb\u6d41\uff08In\uff09\uff1a <strong>16, 25, 32, 40, 63, 80, 100 A<\/strong><\/li>\n<li>\u5b9a\u683c\u611f\u5ea6\uff08I\u0394n\uff09\uff1a <strong>10 \/ 30 \/ 100 \/ 300 mA<\/strong><\/li>\n<li>\u5b9a\u683c\u96fb\u5727 (Ue)\uff1a <strong>240 V~ (2P)<\/strong> \/ <strong>415 V~ (4P)<\/strong><\/li>\n<li>\u7d76\u7e01\u96fb\u5727\uff08Ui\uff09\uff1a <strong>500 V<\/strong> \u00a0 | \u00a0 Frequency: <strong>50\/60 Hz<\/strong><\/li>\n<li>\u6b8b\u7559\u3068\u30d6\u30ec\u30fc\u30af\uff08I\u0394m\uff09\uff1a <strong>500 \/ 630 \/ 800 \/ 1000 A<\/strong> (per In group)<\/li>\n<li>Conditional short-circuit current: <strong>Inc = I\u0394c 6 kA \/ 10 kA<\/strong> (with upstream SCPD)<\/li>\n<li>\u30a4\u30f3\u30d1\u30eb\u30b9\u8010\u91cf\uff08Uimp\uff09\uff1a <strong>4 kV \/ 6 kV<\/strong><\/li>\n<li>Dielectric test voltage: <strong>2.5 kV for 1 min<\/strong> (power frequency)<\/li>\n<li>Tripping behavior: Instantaneous; Short time delay (10\u2013300 ms); Selective S (150\u2013500 ms)<\/li>\n<li>Break time under I\u0394n (Normal): \u2264 100 ms<\/li>\n<li>\u7aef\u5b50\u4fdd\u8b77\u5ea6 <strong>IP20<\/strong><\/li>\n<li>Endurance: \u2265 20,000 mechanical \/ \u2265 2,000 electrical operations<\/li>\n<li>Mounting: DIN rail EN 60715 (35 mm), fast clip<\/li>\n<\/ul>\n<h2>\u6280\u8853\u30c7\u30fc\u30bf<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>\u30e2\u30c7\u30eb<\/th>\n<td>VKL11F<\/td>\n<\/tr>\n<tr>\n<td>\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9<\/td>\n<td>IEC\/EN 61008-1<\/td>\n<\/tr>\n<tr>\n<td>\u30dd\u30fc\u30eb<\/td>\n<td>2P\u30014P<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u96fb\u6d41 (In)<\/td>\n<td>16A\u300125A\u300132A\u300140A\u300163A\u300180A\u3001100A<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u611f\u5ea6 (I\u0394n)<\/td>\n<td>10mA\u300130mA\u3001100mA\u3001300mA<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u96fb\u5727 (Ue)<\/td>\n<td>2P\uff1a240V\u30014P\uff1a415V<\/td>\n<\/tr>\n<tr>\n<td>\u7d76\u7e01\u96fb\u5727 (Ui)<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u5468\u6ce2\u6570<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>\u6b8b\u7559\u3068\u30d6\u30ec\u30fc\u30af\uff08I\u0394m\uff09<\/td>\n<td>500 A\uff0816-40 A\u6642\uff09\uff1b 630 A\uff0863 A\u6642\uff09\uff1b 800 A\uff0880 A\u6642\uff09\uff1b 1000 A\uff08100 A\u6642\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6761\u4ef6\u4ed8\u304d\u77ed\u7d61\u96fb\u6d41\uff08Inc = I\u0394c\uff09<\/td>\n<td>6000 A, 10000 A (with upstream SCPD)<\/td>\n<\/tr>\n<tr>\n<td>\u30a4\u30f3\u30d1\u30eb\u30b9\u8010\u91cf\uff08Uimp\uff09<\/td>\n<td>4 kV \/ 6 kV<\/td>\n<\/tr>\n<tr>\n<td>\u8a98\u96fb\u8a66\u9a13\u96fb\u5727<\/td>\n<td>2.5 kV, 1 min<\/td>\n<\/tr>\n<tr>\n<td>Tripping classes<\/td>\n<td>Instantaneous \/ Short time delay (10\u2013300 ms) \/ Selective S (150\u2013500 ms)<\/td>\n<\/tr>\n<tr>\n<td>\u4f11\u61a9\u6642\u9593<\/td>\n<td>\u2264 100 ms (Normal type)<\/td>\n<\/tr>\n<tr>\n<td>\u6c5a\u67d3\u5ea6<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u96fb\u6c17\u7684\u5bff\u547d<\/td>\n<td>\u2265 2000\u56de\u4ee5\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>\u6a5f\u68b0\u7684\u5bff\u547d<\/td>\n<td>\u2265 20000 operations<\/td>\n<\/tr>\n<tr>\n<td>\u7aef\u5b50\u4fdd\u8b77\u5ea6<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>\u5468\u56f2\u6e29\u5ea6<\/td>\n<td>\u221225 \u00b0C to +55 \u00b0C (daily average \u2264 35 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u5b58\u6e29\u5ea6<\/td>\n<td>-40 \u00b0C \uff5e +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Terminal connection<\/td>\n<td>\u30b1\u30fc\u30d6\u30eb \/ \u30d4\u30f3\u578b\u30d0\u30b9\u30d0\u30fc<\/td>\n<\/tr>\n<tr>\n<td>\u7aef\u5b50\u30b5\u30a4\u30ba\uff08\u30b1\u30fc\u30d6\u30eb\uff09<\/td>\n<td>25-35 mm\u00b2; 18-3 \/ 18-2 AWG<\/td>\n<\/tr>\n<tr>\n<td>\u7aef\u5b50\u30b5\u30a4\u30ba\uff08\u30d0\u30b9\u30d0\u30fc\uff09<\/td>\n<td>10\/16 mm\u00b2; 18-8 \/ 18-5 AWG<\/td>\n<\/tr>\n<tr>\n<td>\u7de0\u3081\u4ed8\u3051\u30c8\u30eb\u30af<\/td>\n<td>2.5 N-m (\u2248 22 in-lbs)<\/td>\n<\/tr>\n<tr>\n<td>\u53d6\u308a\u4ed8\u3051<\/td>\n<td>DIN\u30ec\u30fc\u30eb EN 60715 (35 mm)<\/td>\n<\/tr>\n<tr>\n<td>\u63a5\u7d9a<\/td>\n<td>\u4e0a\u4e0b<\/td>\n<\/tr>\n<tr>\n<td>Waveform class<\/td>\n<td>Type F (mixed-frequency residual currents)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h2>\n<ul>\n<li>Inverter\/UPS outputs, VFD-driven motors, appliances with mixed-frequency leakage<\/li>\n<li>Residential, commercial, and light-industrial panels requiring <strong>\u30bf\u30a4\u30d7f rccb<\/strong> protection<\/li>\n<li>Installations coordinated with upstream SCPD for 6\/10 kA conditional ratings<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"\/images\/rccb-vkl11f.jpg\" alt=\"type f rccb VKL11F Kuangya 2P\/4P 16\u2013100A 10\/30\/100\/300 mA\" \/><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"341\" data-end=\"458\">\n<p data-start=\"343\" data-end=\"458\">Kuangya VKL11F <strong data-start=\"358\" data-end=\"373\">\u30bf\u30a4\u30d7f rccb<\/strong> for mixed-frequency residual-current protection in single- and three-phase systems<\/p>\n<\/li>\n<li data-start=\"459\" data-end=\"551\">\n<p data-start=\"461\" data-end=\"551\">2P\/4P, In 16\u2013100 A; I\u0394n 10\/30\/100\/300 mA; Ue 240 V (2P) \/ 415 V (4P); Ui 500 V; 50\/60 Hz<\/p>\n<\/li>\n<li data-start=\"552\" data-end=\"640\">\n<p data-start=\"554\" data-end=\"640\">Uimp 4\/6 kV; Inc = I\u0394c 6\/10 kA (with upstream SCPD); IP20 terminals; DIN-rail EN 60715<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1815,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-1574","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product\/1574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/comments?post=1574"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media\/1815"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media?parent=1574"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_brand?post=1574"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_cat?post=1574"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_tag?post=1574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}