{"id":1563,"date":"2025-09-15T10:15:21","date_gmt":"2025-09-15T10:15:21","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1563"},"modified":"2025-09-22T09:01:57","modified_gmt":"2025-09-22T09:01:57","slug":"rccb-2%e3%83%9d%e3%83%bc%e3%83%ab-vfl002","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ja\/product\/rccb-2-pole-vfl002\/","title":{"rendered":"RCCB VFL002 - 2\/4\u6975\u6b8b\u7559\u96fb\u6d41\u30b5\u30fc\u30ad\u30c3\u30c8\u30d6\u30ec\u30fc\u30ab"},"content":{"rendered":"<div class=\"product-description\">\n<h2>\u6982\u8981<\/h2>\n<p>The Kuangya VFL002 is an <strong>RCCB 2\u30dd\u30fc\u30eb<\/strong> (also available as 4 pole) residual current device engineered to<br \/>\nprotect people and installations from electric shock and fire risk due to earth-leakage faults. It offers AC, A, and<br \/>\nhigh-immunity ASi detection classes, making it suitable for residential housing, commercial buildings, and light<br \/>\nindustrial facilities. Selection covers rated currents from 16 A to 100 A and sensitivities from 10 mA to 300 mA.<\/p>\n<h2>Detection classes &amp; tripping<\/h2>\n<ul>\n<li><strong>AC\u30af\u30e9\u30b9<\/strong> \u2014 trips for sinusoidal AC residual currents applied slowly or suddenly.<\/li>\n<li><strong>A\u30af\u30e9\u30b9<\/strong> \u2014 AC plus pulsating DC residual currents.<\/li>\n<li><strong>ASi type<\/strong> \u2014 high-immunity A type (G\/KV + Si behavior); filters transients\/harmonics to reduce nuisance tripping.<\/li>\n<\/ul>\n<ul>\n<li><strong>Break time under I\u0394n (Normal):<\/strong> \u2264 100 ms<\/li>\n<li><strong>Short time delay:<\/strong> 10\u2013300 ms (ASi, G, KV types)<\/li>\n<li><strong>Selective S type:<\/strong> 150-500 ms<\/li>\n<\/ul>\n<h2>\u4e3b\u306a\u7279\u5fb4<\/h2>\n<ul>\n<li>\u30b3\u30f3\u30d5\u30a3\u30ae\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\uff1a <strong>2P \/ 4P<\/strong> with top or bottom supply, any mounting position<\/li>\n<li><strong>\u5b9a\u683c\u96fb\u6d41 In\uff1a<\/strong> 16, 25, 32, 40, 63, 80, 100 A<\/li>\n<li><strong>\u5b9a\u683c\u611f\u5ea6 I\u0394n\uff1a<\/strong> 10 mA\uff082P\/4P 16-40 A\uff09\u300130 mA\u3001100 mA\u3001300 mA<\/li>\n<li><strong>\u5b9a\u683c\u96fb\u5727 Ue\uff1a<\/strong> 2P: 240 V~; 4P: 415 V~ \u00a0 | \u00a0 <strong>\u30a6\u30a4\uff1a<\/strong> 500 V | \u00a0 <strong>fn\uff1a<\/strong> 50\/60 Hz<\/li>\n<li><strong>Rated residual making &amp; breaking (I\u0394m):<\/strong> 500 A (In 16\u201340 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)<\/li>\n<li><strong>Inc = I\u0394c (conditional short-circuit):<\/strong> 6 kA or 10 kA (with upstream SCPD coordination)<\/li>\n<li><strong>Impulse withstand Uimp:<\/strong> 6 kV (1.2\/50 \u03bcs); <strong>\u8a98\u96fb\u30c6\u30b9\u30c8\uff1a<\/strong> 2.5 kV \/ 1 min<\/li>\n<li><strong>\u7aef\u5b50\u4fdd\u8b77\uff1a<\/strong> IP20; fault current indicator provided<\/li>\n<li><strong>\u30a2\u30f3\u30d3\u30a8\u30f3\u30c8\uff1a<\/strong> \u221225 \u00b0C \u2026 +55 \u00b0C (daily average \u2264 35 \u00b0C); <strong>\u30b9\u30c8\u30ec\u30fc\u30b8\uff1a<\/strong> \u221240 \u00b0C \u2026 +70 \u00b0C<\/li>\n<li><strong>\u898f\u683c\/\u627f\u8a8d\uff1a<\/strong> IEC\/EN 61008-1; NF, ISI, UKCA, CE<\/li>\n<\/ul>\n<h2>\u6280\u8853\u30c7\u30fc\u30bf<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9<\/th>\n<th>IEC\/EN 61008-1<\/th>\n<\/tr>\n<tr>\n<td>\u30e2\u30c7\u30eb<\/td>\n<td>VFL002<\/td>\n<\/tr>\n<tr>\n<td>\u30dd\u30fc\u30eb<\/td>\n<td>2P\u30014P<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u96fb\u6d41 (In)<\/td>\n<td>16A\u300125A\u300132A\u300140A\u300163A\u300180A\u3001100A<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u611f\u5ea6 (I\u0394n)<\/td>\n<td>10 mA (16\u201340 A), 30 mA, 100 mA, 300 mA<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u96fb\u5727 (Ue)<\/td>\n<td>2P\uff1a240V\u30014P\uff1a415V<\/td>\n<\/tr>\n<tr>\n<td>\u7d76\u7e01\u96fb\u5727 (Ui)<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u5468\u6ce2\u6570<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u6b8b\u7559\u7387\uff08I\u0394m\uff09<\/td>\n<td>500 A\uff08\u5185\u90e8 = 16-40 A\uff09\u3001630 A\uff08\u5185\u90e8 = 63 A\uff09\u3001800 A\uff08\u5185\u90e8 = 80 A\uff09\u30011000 A\uff08\u5185\u90e8 = 100 A\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u6761\u4ef6\u4ed8\u304d\u77ed\u7d61\uff08Inc = I\u0394c\uff09<\/td>\n<td>6000A\u300110000A<\/td>\n<\/tr>\n<tr>\n<td>Waveform sensitivity<\/td>\n<td>AC, A, ASi<\/td>\n<\/tr>\n<tr>\n<td>Tripping time classes<\/td>\n<td>Instantaneous \/ Short time delay (10\u2013300 ms) \/ Selective S (150\u2013500 ms)<\/td>\n<\/tr>\n<tr>\n<td>Break time under I\u0394n (Normal)<\/td>\n<td>\u2264 100 ms<\/td>\n<\/tr>\n<tr>\n<td>\u30a4\u30f3\u30d1\u30eb\u30b9\u8010\u91cf\uff08Uimp\uff09<\/td>\n<td>6 kV<\/td>\n<\/tr>\n<tr>\n<td>\u8a98\u96fb\u8a66\u9a13\u96fb\u5727<\/td>\n<td>2.5 kV (1 min at power frequency)<\/td>\n<\/tr>\n<tr>\n<td>\u6c5a\u67d3\u5ea6<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u96fb\u6c17\u7684\u5bff\u547d<\/td>\n<td>\u2265 2000\u56de\u4ee5\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>\u6a5f\u68b0\u7684\u5bff\u547d<\/td>\n<td>\u2265 2000\u56de\u4ee5\u4e0a<\/td>\n<\/tr>\n<tr>\n<td>\u6545\u969c\u96fb\u6d41\u30a4\u30f3\u30b8\u30b1\u30fc\u30bf\u30fc<\/td>\n<td>\u306f\u3044<\/td>\n<\/tr>\n<tr>\n<td>\u7aef\u5b50\u4fdd\u8b77\u5ea6<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature (avg \u2264 35 \u00b0C)<\/td>\n<td>-25 \u00b0C \uff5e +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u4fdd\u5b58\u6e29\u5ea6<\/td>\n<td>-40 \u00b0C \uff5e +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Terminal connection<\/td>\n<td>\u30b1\u30fc\u30d6\u30eb \/ \u30d4\u30f3\u578b\u30d0\u30b9\u30d0\u30fc<\/td>\n<\/tr>\n<tr>\n<td>Terminal size (cable, top\/bottom)<\/td>\n<td>25\u201335 mm\u00b2; 18\u20133 \/ 18\u20132 AWG (per size class)<\/td>\n<\/tr>\n<tr>\n<td>Terminal size (busbar, top\/bottom)<\/td>\n<td>10\/16 mm\u00b2; 18-8 \/ 18-5 AWG<\/td>\n<\/tr>\n<tr>\n<td>\u7de0\u3081\u4ed8\u3051\u30c8\u30eb\u30af<\/td>\n<td>2.5 N-m (\u2248 22 in-lbs)<\/td>\n<\/tr>\n<tr>\n<td>\u53d6\u308a\u4ed8\u3051<\/td>\n<td>DIN\u30ec\u30fc\u30eb EN 60715 (35 mm)\u3001\u30d5\u30a1\u30b9\u30c8\u30af\u30ea\u30c3\u30d7<\/td>\n<\/tr>\n<tr>\n<td>\u63a5\u7d9a<\/td>\n<td>\u4e0a\u304b\u3089<\/td>\n<\/tr>\n<tr>\n<td>\u627f\u8a8d<\/td>\n<td>NF, ISI, UKCA, CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h2>\n<ul>\n<li>\u3092\u5fc5\u8981\u3068\u3059\u308b\u5358\u76f8\u30dc\u30fc\u30c9\u3002 <strong>RCCB 2\u30dd\u30fc\u30eb<\/strong> device at 240 V~<\/li>\n<li>Three-phase distribution using 4P at 415 V~ with coordinated upstream SCPD<\/li>\n<li>Loads with electronics and frequent transients \u2014 use ASi high-immunity version<\/li>\n<\/ul>\n<h2>\u8a8d\u8a3c<\/h2>\n<p>\u6e96\u62e0 <strong>IEC\/EN 61008-1<\/strong>; certified <strong>NF, ISI, UKCA, CE<\/strong>.<\/p>\n<h2>\u3088\u304f\u3042\u308b\u3054\u8cea\u554f<\/h2>\n<details>\n<summary>When do I choose 2P vs 4P?<\/summary>\n<p>Use 2P for single-phase 240 V~ systems and 4P for three-phase 415 V~ systems.<\/p>\n<\/details>\n<details>\n<summary>What sensitivity should I select?<\/summary>\n<p>10\/30 mA for additional personal protection; 100\/300 mA for fire protection and selectivity.<\/p>\n<\/details>\n<details>\n<summary>How to coordinate conditional short-circuit rating?<\/summary>\n<p>Use an upstream breaker\/fuse so the installation respects <strong>Inc = I\u0394c<\/strong> (6 kA \/ 10 kA) under fault conditions.<\/p>\n<\/details>\n<p><img decoding=\"async\" src=\"\/images\/rccb-vfl002.jpg\" alt=\"rccb 2 pole VFL002 Kuangya, 2P\/4P 16\u2013100A 10\/30\/100\/300 mA\" \/><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul data-start=\"303\" data-end=\"585\">\n<li data-start=\"303\" data-end=\"413\">\n<p data-start=\"305\" data-end=\"413\"><strong data-start=\"305\" data-end=\"320\">RCCB 2\u30dd\u30fc\u30eb<\/strong> for reliable earth-leakage protection in single-phase and three-phase boards (2P\/4P range)<\/p>\n<\/li>\n<li data-start=\"414\" data-end=\"513\">\n<p data-start=\"416\" data-end=\"513\">In: 16\u2013100A; I\u0394n: 10\/30\/100\/300 mA; Ue: 240 V (2P) \/ 415 V (4P); Inc=I\u0394c up to 10 kA; Uimp 6 kV<\/p>\n<\/li>\n<li data-start=\"514\" data-end=\"585\">\n<p data-start=\"516\" data-end=\"585\">AC \/ A \/ ASi options; IEC\/EN 61008-1 with NF, ISI, UKCA, CE approvals<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1797,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-1563","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product\/1563","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/comments?post=1563"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media\/1797"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media?parent=1563"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_brand?post=1563"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_cat?post=1563"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_tag?post=1563"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}