{"id":1386,"date":"2025-09-10T08:57:23","date_gmt":"2025-09-10T08:57:23","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1386"},"modified":"2025-12-01T06:44:28","modified_gmt":"2025-12-01T06:44:28","slug":"type-2-3-surge-protection-device-1p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ja\/product\/type-2-3-surge-protection-device-1p\/","title":{"rendered":"2+3\u5f62\u30b5\u30fc\u30b8\u9632\u8b77\u30c7\u30d0\u30a4\u30b91P KYSPD-20T2+3-1P\uff5cKuangya"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-20T2+3-1P is a compact <strong>type 2+3 surge protection device 1P<\/strong><br \/>\ndesigned for single-phase electrical panels at 230 V AC. It combines Type 2 and Type 3 protection<br \/>\nclasses, making it suitable for downstream circuits where sensitive equipment requires enhanced<br \/>\nsurge suppression.This SPD features MOV-based surge absorption with a pluggable cartridge design,<br \/>\nintegrated thermal disconnector, and clear green\/red status indicator. Optional RC contacts<br \/>\nallow remote fault signaling for integration with building management systems or control panels.<\/p>\n<\/section>\n<section id=\"features\">\n<h3>\u4e3b\u306a\u7279\u5fb4<\/h3>\n<ul>\n<li>Class II+III \/ Type 2+3 surge protective device (1P).<\/li>\n<li>\u516c\u79f0\u653e\u96fb\u96fb\u6d41 (In)\uff1a10 kA (8\/20 \u03bcs)\u3002.<\/li>\n<li>\u6700\u5927\u653e\u96fb\u96fb\u6d41 (Imax)\uff1a20 kA\uff088\/20 \u03bcs\uff09\u3002.<\/li>\n<li>\u96fb\u5727\u4fdd\u8b77\u30ec\u30d9\u30eb (Up): Uc (75-440 V) \u306b\u5fdc\u3058\u3066\u2264 0.3-1.8 kV\u3002.<\/li>\n<li>\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u904e\u6e21\u6291\u5236\u306e\u305f\u3081\u306e\u9ad8\u901f\u5fdc\u7b54\u6642\u9593&lt;25 ns\u3002<\/li>\n<li>\u30d0\u30c3\u30af\u30a2\u30c3\u30d7\u30d2\u30e5\u30fc\u30ba\uff1a\u6700\u592763 A gL\/gG; ISCCR 10 kA AC\u3002.<\/li>\n<li>\u30aa\u30d7\u30b7\u30e7\u30f3\u306eRC\u4fe1\u53f7\u63a5\u70b9\uff1aAC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A\u3002.<\/li>\n<li>Thermoplastic UL94 V-0 housing, IP20; operating temperature -40 \u00b0C to +70 \u00b0C.<\/li>\n<li>DIN\u30ec\u30fc\u30eb\u53d6\u4ed8\uff0835 mm\u3001EN 60715\uff09\u3001IEC\/EN 61643-11\u6e96\u62e0\u3002.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u4ed5\u69d8<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u5546\u54c1\u30b3\u30fc\u30c9<\/th>\n<td>KYSPD-20T2+3-1P<\/td>\n<\/tr>\n<tr>\n<th>\u30ab\u30c6\u30b4\u30ea\u30fc<\/th>\n<td>Type 2+3 surge protection device 1P<\/td>\n<\/tr>\n<tr>\n<th>\u516c\u79f0\u30b7\u30b9\u30c6\u30e0\u96fb\u5727<\/th>\n<td>AC230V<\/td>\n<\/tr>\n<tr>\n<th>\u30dd\u30fc\u30eb<\/th>\n<td>1P (Single-phase)<\/td>\n<\/tr>\n<tr>\n<th>\u9023\u7d9a\u52d5\u4f5c\u96fb\u5727 (Uc)<\/th>\n<td>75 \/ 150 \/ 275 \/ 320 \/ 385 \/ 440 V<\/td>\n<\/tr>\n<tr>\n<th>\u516c\u79f0\u653e\u96fb\u96fb\u6d41\uff08In\u30018\/20 \u03bcs\uff09<\/th>\n<td>10 kA<\/td>\n<\/tr>\n<tr>\n<th>\u6700\u5927\u653e\u96fb\u96fb\u6d41\uff08Imax\u30018\/20 \u03bcs\uff09<\/th>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<th>\u96fb\u5727\u4fdd\u8b77\u30ec\u30d9\u30eb\uff08\u4e0a\uff09<\/th>\n<td>\u2264 0.3-1.8 kV<\/td>\n<\/tr>\n<tr>\n<th>\u5fdc\u7b54\u6642\u9593<\/th>\n<td>&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<th>\u30d0\u30c3\u30af\u30a2\u30c3\u30d7\u30d2\u30e5\u30fc\u30ba\uff08\u6700\u5927\uff09<\/th>\n<td>63 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<th>\u77ed\u7d61\u96fb\u6d41\u5b9a\u683c\uff08ISCCR\uff09<\/th>\n<td>\u4ea4\u6d4110kA<\/td>\n<\/tr>\n<tr>\n<th>\u52d5\u4f5c\u6e29\u5ea6<\/th>\n<td>-40 \u00b0C \uff5e +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u53d6\u308a\u4ed8\u3051<\/th>\n<td>35 mm DIN\u30ec\u30fc\u30eb\u3001EN 60715<\/td>\n<\/tr>\n<tr>\n<th>\u30a8\u30f3\u30af\u30ed\u30fc\u30b8\u30e3\u30fc\uff0f\u4fdd\u8b77<\/th>\n<td>\u71b1\u53ef\u5851\u6027 UL94 V-0 \/ IP20<\/td>\n<\/tr>\n<tr>\n<th>\u30ea\u30e2\u30fc\u30c8\u4fe1\u53f7\uff08RC\uff09<\/th>\n<td>\u30aa\u30d7\u30b7\u30e7\u30f3; AC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A<\/td>\n<\/tr>\n<tr>\n<th>\u898f\u683c<\/th>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u914d\u7dda\u3068\u5bf8\u6cd5<\/h3>\n<p>Connection diagram type 2+3 surge protection device 1P KYSPD-20T2+3-1P<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1388\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P-wiring-diagram-1-300x276.png\" alt=\"Connection diagram type 2+3 surge protection device 1P KYSPD-20T2+3-1P\" width=\"400\" height=\"368\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P-wiring-diagram-1-300x276.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P-wiring-diagram-1.png 533w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<p>Dimensions type 2+3 surge protection device 1P KYSPD-20T2+3-1P<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1389\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P-dimension-1-300x280.png\" alt=\"Dimensions type 2+3 surge protection device 1P KYSPD-20T2+3-1P\" width=\"401\" height=\"374\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P-dimension-1-300x280.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P-dimension-1.png 441w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \/><\/p>\n<\/section>\n<section id=\"applications\">\n<h3>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h3>\n<ul>\n<li>Single-phase distribution panels in residential and office buildings.<\/li>\n<li>Protection of sensitive electronic devices and appliances from transient surges.<\/li>\n<li>Downstream coordination with upstream Type 1 surge arresters in TT\/TN networks.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u3088\u304f\u3042\u308b\u3054\u8cea\u554f<\/h3>\n<ul>\n<li><strong>What class of SPD is KYSPD-20T2+3-1P?<\/strong> IEC\/EN 61643-11\u306b\u3088\u308b\u30af\u30e9\u30b9II+III\u3001\u30bf\u30a4\u30d72+3\u3067\u3059\u3002.<\/li>\n<li><strong>\u30b5\u30fc\u30b8\u653e\u96fb\u5bb9\u91cf\u306f\uff1f<\/strong> 10kA\u3067\u30011\u6975\u3042\u305f\u308aImax 20kA\u3002.<\/li>\n<li><strong>Where can it be installed?<\/strong> In single-phase 230 V AC electrical panels.<\/li>\n<li><strong>\u30ea\u30e2\u30fc\u30c8\u6545\u969c\u30b7\u30b0\u30ca\u30ea\u30f3\u30b0\u306e\u6a5f\u80fd\u306f\u3042\u308a\u307e\u3059\u304b\uff1f<\/strong> \u306f\u3044\u3001\u30aa\u30d7\u30b7\u30e7\u30f3\u3067RC\u63a5\u70b9\u304c\u5229\u7528\u3067\u304d\u307e\u3059\u3002.<\/li>\n<li><strong>\u30d0\u30c3\u30af\u30a2\u30c3\u30d7\u30d2\u30e5\u30fc\u30ba\u306e\u6700\u5927\u5b9a\u683c\u306f\uff1f<\/strong> 63 A gL\/gG.<\/li>\n<\/ul>\n<\/section>\n<section id=\"cta\">\u8a73\u7d30\u306a\u4fa1\u683c\u3068\u6280\u8853\u30b5\u30dd\u30fc\u30c8\u306b\u3064\u3044\u3066\u306f <a href=\"\/ja\/contact-us\/\">\u304a\u554f\u3044\u5408\u308f\u305b<\/a>.\u3082\u3063\u3068Kuangya\u306e\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63a2\u308b <a href=\"\/ja\/%e7%9b%b4%e6%b5%81%e5%9b%9e%e8%bb%a2%e6%95%b0\/\">DC SPD<\/a>, <a href=\"\/ja\/ac-surge-protective-device\/\">AC\u30b5\u30fc\u30b8\u4fdd\u8b77<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"608\" data-end=\"693\">\n<p data-start=\"610\" data-end=\"693\"><strong data-start=\"610\" data-end=\"649\">Type 2+3 surge protection device 1P<\/strong> for single-phase AC systems at <strong data-start=\"681\" data-end=\"690\">230 V<\/strong>.<\/p>\n<\/li>\n<li data-start=\"694\" data-end=\"799\">\n<p data-start=\"696\" data-end=\"799\">\u30b5\u30fc\u30b8\u5b9a\u683c\uff1a <strong data-start=\"711\" data-end=\"733\">10kA\u6642 (8\/20 \u00b5s)<\/strong>, <strong data-start=\"735\" data-end=\"759\">\u6700\u592720 kA\uff088\/20 \u00b5s\uff09<\/strong>, <strong data-start=\"761\" data-end=\"780\">\u30a2\u30c3\u30d7\u2264 0.3-1.8 kV<\/strong> Uc\u306b\u4f9d\u5b58\u3059\u308b\u3002.<\/p>\n<\/li>\n<li data-start=\"800\" data-end=\"918\">\n<p data-start=\"802\" data-end=\"918\">Compact pluggable DIN-rail module, thermal disconnector with status indicator, <strong data-start=\"881\" data-end=\"915\">\u30aa\u30d7\u30b7\u30e7\u30f3\u306eRC\u4fe1\u53f7\u63a5\u70b9<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1578,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1386","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product\/1386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/comments?post=1386"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media\/1578"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/media?parent=1386"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_brand?post=1386"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_cat?post=1386"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ja\/wp-json\/wp\/v2\/product_tag?post=1386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}