{"id":1488,"date":"2025-09-12T06:05:31","date_gmt":"2025-09-12T06:05:31","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1488"},"modified":"2025-09-12T06:13:47","modified_gmt":"2025-09-12T06:13:47","slug":"kgld-dual-power-automatic-transfer-switch","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/it\/product\/kgld-dual-power-automatic-transfer-switch\/","title":{"rendered":"Interruttore di trasferimento automatico a doppia potenza KGLD (20-3200A)"},"content":{"rendered":"<section id=\"overview\">\n<p data-start=\"275\" data-end=\"742\">Il <strong data-start=\"279\" data-end=\"337\">Interruttore di trasferimento automatico (ATS) a doppia potenza serie KGLD<\/strong> \u00e8 un'affidabile <strong data-start=\"352\" data-end=\"392\">Interruttore di trasferimento automatico a doppia potenza<\/strong> progettato per la commutazione tra alimentazione principale e di riserva o tra rete e generatore.<br data-start=\"469\" data-end=\"472\" \/>Grazie al design compatto, all'elevata velocit\u00e0 di commutazione e alla conformit\u00e0 alla norma IEC 60947-6-1, la serie KGLD garantisce un funzionamento stabile nelle strutture critiche.<br data-start=\"616\" data-end=\"619\" \/>Offre il trasferimento automatico, l'interblocco elettrico e meccanico e una posizione \u201c0\u201d forzata opzionale per la manutenzione.<\/p>\n<h3 data-start=\"744\" data-end=\"760\">Applicazioni<\/h3>\n<ul data-start=\"761\" data-end=\"1044\">\n<li data-start=\"761\" data-end=\"826\">\n<p data-start=\"763\" data-end=\"826\">Ospedali, banche e centri dati che richiedono alimentazione continua<\/p>\n<\/li>\n<li data-start=\"827\" data-end=\"898\">\n<p data-start=\"829\" data-end=\"898\">Impianti industriali che utilizzano <strong data-start=\"857\" data-end=\"886\">interruttore di trasferimento automatico<\/strong> attrezzature<\/p>\n<\/li>\n<li data-start=\"899\" data-end=\"969\">\n<p data-start=\"901\" data-end=\"969\">Edifici residenziali e commerciali con alimentazione a doppia sorgente<\/p>\n<\/li>\n<li data-start=\"970\" data-end=\"1044\">\n<p data-start=\"972\" data-end=\"1044\">Sistemi di backup del generatore con <strong data-start=\"1002\" data-end=\"1042\">Interruttore di trasferimento automatico a doppia potenza<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1046\" data-end=\"1062\">Caratteristiche principali<\/h3>\n<ul data-start=\"1063\" data-end=\"1528\">\n<li data-start=\"1063\" data-end=\"1141\">\n<p data-start=\"1065\" data-end=\"1141\">Ampio intervallo di corrente: 20-1600A, adatto a varie applicazioni di interruttori ATS<\/p>\n<\/li>\n<li data-start=\"1142\" data-end=\"1199\">\n<p data-start=\"1144\" data-end=\"1199\">Tensione di lavoro nominale: AC400V, isolamento fino a 1000V<\/p>\n<\/li>\n<li data-start=\"1200\" data-end=\"1244\">\n<p data-start=\"1202\" data-end=\"1244\">Elevata capacit\u00e0 di cortocircuito: fino a 120kA<\/p>\n<\/li>\n<li data-start=\"1245\" data-end=\"1291\">\n<p data-start=\"1247\" data-end=\"1291\">Commutazione rapida: tempo di conversione 0,45s-1,2s<\/p>\n<\/li>\n<li data-start=\"1292\" data-end=\"1344\">\n<p data-start=\"1294\" data-end=\"1344\">Soddisfa gli standard IEC 60947-6-1 \/ GB\/T14048.11 ATS<\/p>\n<\/li>\n<li data-start=\"1345\" data-end=\"1402\">\n<p data-start=\"1347\" data-end=\"1402\">Supporta il trasferimento manuale e automatico<\/p>\n<\/li>\n<li data-start=\"1403\" data-end=\"1528\">\n<p data-start=\"1405\" data-end=\"1528\">Disponibile nei modelli 3P e 4P, \u00e8 ideale come <strong data-start=\"1447\" data-end=\"1487\">Interruttore di trasferimento automatico a doppia potenza<\/strong> per progetti commerciali e industriali<\/p>\n<\/li>\n<\/ul>\n<\/section>\n<section id=\"parameters\">\n<h2>Parametri tecnici principali<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th>Corrente nominale (A)<\/th>\n<th>Tensione nominale di isolamento Ui (V)<\/th>\n<th>Tensione nominale di tenuta all'impulso Uimp (kV)<\/th>\n<th>Tensione nominale di esercizio Ue (V)<\/th>\n<th>AC-31A Corrente nominale (A)<\/th>\n<th>AC-35A Corrente nominale (A)<\/th>\n<th>AC-33A Corrente nominale (A)<\/th>\n<th>Capacit\u00e0 produttiva nominale<\/th>\n<th>Capacit\u00e0 di rottura nominale<\/th>\n<th>Capacit\u00e0 nominale di cortocircuito limitato (kA)<\/th>\n<th>Corrente nominale di breve durata (kA)<\/th>\n<th>Tempo di conversione I\u2194II (s)<\/th>\n<th>Tensione di controllo<\/th>\n<th>Avvio della potenza del motore (W)<\/th>\n<th>Potenza del motore Normale (W)<\/th>\n<th>Peso (kg)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>20<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>63<\/td>\n<td>63<\/td>\n<td>63<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>325<\/td>\n<td>62<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>160<\/td>\n<td>160<\/td>\n<td>160<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>62<\/td>\n<td>8.8<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>62<\/td>\n<td>9.0<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>9<\/td>\n<td>0.6<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>74<\/td>\n<td>16.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>630<\/td>\n<td>630<\/td>\n<td>630<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>9<\/td>\n<td>0.6<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>74<\/td>\n<td>17.0<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>70<\/td>\n<td>13<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>90<\/td>\n<td>32.0<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>70<\/td>\n<td>26<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>36.0<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1250<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>100<\/td>\n<td>50<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>40.0<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1600<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>120<\/td>\n<td>50<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>43.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h2>Cablaggio del circuito principale<\/h2>\n<p>L'interruttore di trasferimento automatico KGLD offre diverse modalit\u00e0 di cablaggio a seconda del progetto del sistema, tra cui:<\/p>\n<ul>\n<li>Tipo di connessione economica (sotto i 100A)<\/li>\n<li>Modalit\u00e0 di collegamento segnale passivo + terminale antincendio attivo (100-630A)<\/li>\n<li>Collegamento completamente automatico (160-1600A)<\/li>\n<li>Impostazione forzata \u201c0\u201d completamente automatica (entrambe le sorgenti scollegate)<\/li>\n<li>Modalit\u00e0 di collegamento dell'uscita del segnale del generatore<\/li>\n<li>Automatico + Manuale (telecomando)<\/li>\n<li>Cablaggio con controllore (100-1600A)<\/li>\n<\/ul>\n<p><em>Gli schemi di cablaggio dettagliati sono disponibili nel catalogo dei prodotti e devono essere rigorosamente seguiti durante l'installazione.<\/em><\/p>\n<\/section>\n<section id=\"standards\">\n<h2>Standard e conformit\u00e0<\/h2>\n<p>La serie KGLD \u00e8 conforme ai seguenti standard internazionali:<\/p>\n<ul>\n<li>IEC 60947-1 \/ GB\/T 14048.1 (Apparecchiature di comando e controllo a bassa tensione - Regole generali)<\/li>\n<li>IEC 60947-3 \/ GB\/T 14048.3 (Sezionatori, isolatori, unit\u00e0 di combinazione di fusibili)<\/li>\n<li>IEC 60947-6-1 \/ GB\/T 14048.11 (Apparecchiatura di commutazione automatica di trasferimento - ATS)<\/li>\n<li>Certificato per la sicurezza, le prestazioni e la durata di vita.<\/li>\n<\/ul>\n<\/section>\n<section id=\"selection-guide\">\n<h2>Guida alla selezione<\/h2>\n<p>Nella scelta di un interruttore di trasferimento automatico KGLD, considerare i seguenti fattori:<\/p>\n<ol>\n<li><strong>Corrente nominale (20A-1600A)<\/strong> \u2192 Selezionare in base al carico totale.<\/li>\n<li><strong>Pali<\/strong> \u2192 3P per sistemi trifase a tre fili, 4P per sistemi trifase a quattro fili.<\/li>\n<li><strong>Metodo di controllo<\/strong> \u2192 Automatico o manuale; telecomando opzionale.<\/li>\n<li><strong>Tempo di conversione<\/strong> \u2192 0,45s-1,2s a seconda del modello.<\/li>\n<li><strong>Capacit\u00e0 di cortocircuito<\/strong> \u2192 Fino a 120kA per valori nominali maggiori.<\/li>\n<li><strong>Metodo di installazione<\/strong> \u2192 Maniglia a pannello o a porta.<\/li>\n<li><strong>Standard e certificazione<\/strong> \u2192 Verifica della conformit\u00e0 IEC\/GB e della conformit\u00e0 del progetto.<\/li>\n<\/ol>\n<\/section>\n<section id=\"faq\">\n<h2>FAQ<\/h2>\n<details>\n<summary>Qual \u00e8 la principale differenza tra le serie KGLD e KGQ2?<\/summary>\n<p>KGLD \u00e8 un ATS automatico motorizzato con un ampio intervallo di corrente (20-1600A), mentre KGQ2 si concentra sugli interruttori di potenza doppi in cassa stampata con diverse applicazioni.<\/p>\n<\/details>\n<details>\n<summary>Il KGLD pu\u00f2 essere utilizzato con un generatore di riserva?<\/summary>\n<p>S\u00ec. Supporta il trasferimento da rete a generatore, con rilevamento automatico della tensione e commutazione sicura.<\/p>\n<\/details>\n<details>\n<summary>Il KGLD supporta il controllo a distanza?<\/summary>\n<p>S\u00ec, le modalit\u00e0 di cablaggio includono il telecomando manuale e il funzionamento basato su controller per i sistemi intelligenti.<\/p>\n<\/details>\n<details>\n<summary>Qual \u00e8 la durata di vita di KGLD?<\/summary>\n<p>Resistenza meccanica \u22658000 operazioni, resistenza elettrica \u22656000 operazioni in condizioni nominali.<\/p>\n<\/details>\n<details>\n<summary>\u00c8 certificato?<\/summary>\n<p>S\u00ec, conforme a IEC 60947-6-1, IEC 60947-3, GB\/T14048.11 e agli standard correlati.<\/p>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>L'interruttore di trasferimento automatico (ATS) isolato a doppia potenza della serie Kuangya KGLD, che copre 20A-3200A, \u00e8 stato progettato per un'affidabile commutazione della rete elettrica \u2194 del generatore.<\/p>\n<p>Presenta una commutazione rapida, un controllore ATS integrato, un meccanismo di azionamento del motore, un'elevata resistenza dielettrica e una durata di vita di &gt;8000 operazioni.<\/p>\n<p>Adatto per ospedali, banche, grattacieli, impianti industriali e altre applicazioni critiche che richiedono un'alimentazione ininterrotta.<\/p>","protected":false},"featured_media":1491,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[32],"product_tag":[],"class_list":{"0":"post-1488","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-transfer-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/product\/1488","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/comments?post=1488"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/media\/1491"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/media?parent=1488"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/product_brand?post=1488"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/product_cat?post=1488"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/it\/wp-json\/wp\/v2\/product_tag?post=1488"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}