RCCB VKL11 (B/B+) - Interruttore automatico per correnti di guasto

  • The Kuangya VKL11 b type rccb provides residual-current protection with Type B/B+ detection suitable for AC and DC leakage conditions

  • 2P / 4P; In 16–100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Ui 500 V; 50/60 Hz

  • Uimp 4/6 kV (per variant); Inc = IΔc 6/10 kA (with upstream SCPD); IP20 terminals; DIN-rail EN 60715

Richiedi un preventivo

Categoria:

Panoramica

VKL11 (B/B+) is a b type rccb designed to disconnect the circuit when residual current exceeds
the threshold, helping prevent electric shock and fire hazards due to insulation faults. The Type B/B+ variants
are suitable for leakage containing smooth DC and higher-frequency components often present with frequency
converters, inverters, PV/EV equipment, and VFD-driven motors. Pole options include 2P for single-phase and
4P for three-phase systems.

Caratteristiche principali

  • Pali: 2P / 4P
  • Corrente nominale (In): 16, 25, 32, 40, 63, 80, 100 A
  • Rated sensitivity (IΔn): 10 / 30 / 100 / 300 mA
  • Tensione nominale (Ue): 240 V~ (2P) / 415 V~ (4P); Ui: 500 V; Frequency: 50/60 Hz
  • Residual making & breaking (IΔm): 500 / 630 / 800 / 1000 A (per In group)
  • Conditional short-circuit (Inc = IΔc): 6000 A / 10000 A (with upstream SCPD coordination)
  • Impulse withstand (Uimp): 4 kV / 6 kV (by variant)
  • Terminal protection: IP20; DIN rail EN 60715 (35 mm) mounting

Technical Data

ModelloVKL11 (B/B+)
StandardIEC/EN 61008-1
Pali2P, 4P
Corrente nominale (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated sensitivity (IΔn)10 mA, 30 mA, 100 mA, 300 mA
Tensione nominale (Ue)2P: 240 V~; 4P: 415 V~
Insulation voltage (Ui)500 V
Rated frequency50/60 Hz
Residual making & breaking (IΔm)500 A (In 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)
Conditional short-circuit (Inc = IΔc)6000 A; 10000 A
Impulse withstand (Uimp)4 kV / 6 kV (per variant)
Terminal protection degreeIP20
Ambient temperature−25 °C to +55 °C (daily avg ≤ 35 °C)
Storage temperature−40 °C to +70 °C
Terminal connectionCavo / sbarra di tipo Pin
Terminal size (cable)25–35 mm²
Terminal size (busbar)10/16 mm²
Tightening torque2.5 N·m
MontaggioDIN rail EN 60715 (35 mm)
ConnectionTop and bottom
Waveform classesType B / B+ (DC-capable); AC, A (where applicable by variant)

Applicazioni

  • PV arrays, EV charging, variable-frequency drives, UPS/inverters requiring b type rccb
  • Three-phase boards (4P) and single-phase boards (2P) with leakage containing DC or high-frequency components
  • Installations coordinated with upstream SCPD for 6/10 kA conditional short-circuit ratings

b type rccb VKL11 (B/B+) Kuangya 2P/4P 16–100A 10/30/100/300 mA

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “RCCB VKL11 (B/B+) — Residual Current Circuit Breaker”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *