VKL003 / VKL003N RCBO - Singolo polo + neutro (1P+N) 5-40A

  • rcbo single pole (1P+N) RCBO for residential & commercial branches, In 5–40A, curves B/C.

  • Tipo AC / Tipo A, sensitivities IΔn 6 / 10 / 30 / 100 / 300 mA; Icn up to 10 kA @ 240 V (VKL003) / 15 kA @ 120 V (VKL003N).

  • SEMKO / UKCA / CE / SAA certified; electrical & mechanical endurance 2,000 cycles; DIN-rail mounting with front test button.

Richiedi un preventivo

Categoria:

rcbo unipolare VKL003 / VKL003N is a compact 1P+N residual-current circuit breaker with overcurrent protection, rated 5–40 A with Type AC/A, multiple sensitivities, and B/C curves for residential and commercial distribution circuits.

Panoramica

VKL003 and VKL003N provide combined protection against overload, short circuit, and
residual current faults on single-phase branches. Both share the same 1P+N form factor
and current range (5–40 A). VKL003 targets 240 V systems with breaking capacity
up to 10 kA, while VKL003N is optimized for 120 V systems with
15 kA Icn. Type AC and Type A options plus five sensitivity levels enable precise
coordination across lighting and socket circuits.

Caratteristiche principali

  • Form factor: 1P+N (single-pole + neutral), compact modular width
  • Corrente nominale (In): 5–40 A (typical steps: 5/6/10/16/20/25/32/40 A)
  • Tipo di corrente residua: Tipo AC / Tipo A
  • Sensitivities (IΔn): 6 / 10 / 30 / 100 / 300 mA
  • Tripping curves: B (3–5×In), C (5–10×In)
  • Capacità di rottura (Icn): VKL003 4.5/6/10 kA @ 240 V; VKL003N 15 kA @ 120 V
  • Frequency: 50/60 Hz; front test button (T) for routine verification
  • Service life: electrical 2,000 cycles / mechanical 2,000 cycles
  • Mounting: DIN-rail; front wiring; compact installation depth

RCBO Single Pole Technical Data — VKL003 / VKL003N

ParametroVKL003VKL003N
Pali1P+N (single-pole + neutral)
Corrente nominale (In)5–40 A5–40 A
Tensione nominale (Ue)AC 240 VAC 120 V
Frequenza50/60 Hz
Tipo di corrente residuaTipo AC / Tipo A
Corrente residua nominale (IΔn)6 / 10 / 30 / 100 / 300 mA
Tripping characteristic (MCB curve)B: 3–5 × In; C: 5–10 × In
Capacità di rottura (Icn)4.5 / 6 / 10 kA @ 240 V15 kA @ 120 V
ResistenzaElectrical 2,000 cycles; Mechanical 2,000 cycles
InstallazioneGuida DIN; cablaggio anteriore; pulsante di prova (T)
Recommended applicationsResidential & commercial lighting and socket branches
CertificazioniSEMKO, UKCA, CE, SAA
StandardIEC/EN 61009-1

Applicazioni

  • Apartments & houses: lighting and socket circuits up to 40 A
  • Commercial offices & retail: small-load branch protection
  • Public buildings: admin rooms, classrooms, auxiliary circuits
 

Standard e conformità

Conforms to IEC/EN 61009-1. Certified by SEMKO, UKCA, CE, SAA.
Coordinate with upstream protection and follow local codes for selectivity and fault levels.

FAQ

What is the difference between VKL003 and VKL003N?

Both are 1P+N, 5–40 A with Type AC/A and five IΔn levels. VKL003 is for 240 V (up to 10 kA Icn); VKL003N is for 120 V (15 kA Icn).

When should I choose curve B or curve C?

Use curve B (3–5×In) for resistive/lightly inductive loads; use curve C (5–10×In) for circuits with higher inrush such as motors or transformers.

What is the advantage of an rcbo single pole form factor?

The compact 1P+N layout saves rail width while providing full residual and overcurrent protection—ideal for lighting and socket branches.

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “VKL003 / VKL003N RCBO — Single-Pole + Neutral (1P+N) 5–40A”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *