RCCB VFL002 - Interruttore automatico per correnti di guasto a 2/4 poli

  • rccb 2 poli for reliable earth-leakage protection in single-phase and three-phase boards (2P/4P range)

  • In: 16–100A; IΔn: 10/30/100/300 mA; Ue: 240 V (2P) / 415 V (4P); Inc=IΔc up to 10 kA; Uimp 6 kV

  • AC / A / ASi options; IEC/EN 61008-1 with NF, ISI, UKCA, CE approvals

Richiedi un preventivo

Categoria:

Panoramica

The Kuangya VFL002 is an rccb 2 poli (also available as 4 pole) residual current device engineered to
protect people and installations from electric shock and fire risk due to earth-leakage faults. It offers AC, A, and
high-immunity ASi detection classes, making it suitable for residential housing, commercial buildings, and light
industrial facilities. Selection covers rated currents from 16 A to 100 A and sensitivities from 10 mA to 300 mA.

Detection classes & tripping

  • Classe AC — trips for sinusoidal AC residual currents applied slowly or suddenly.
  • Una classe — AC plus pulsating DC residual currents.
  • ASi type — high-immunity A type (G/KV + Si behavior); filters transients/harmonics to reduce nuisance tripping.
  • Break time under IΔn (Normal): ≤ 100 ms
  • Short time delay: 10–300 ms (ASi, G, KV types)
  • Selective S type: 150-500 ms

Caratteristiche principali

  • Configurazioni: 2P / 4P with top or bottom supply, any mounting position
  • Corrente nominale In: 16, 25, 32, 40, 63, 80, 100 A
  • Sensibilità nominale IΔn: 10 mA (2P/4P 16-40 A), 30 mA, 100 mA, 300 mA
  • Tensione nominale Ue: 2P: 240 V~; 4P: 415 V~   |   Ui: 500 V |   fn: 50/60 Hz
  • Rated residual making & breaking (IΔm): 500 A (In 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)
  • Inc = IΔc (conditional short-circuit): 6 kA or 10 kA (with upstream SCPD coordination)
  • Impulse withstand Uimp: 6 kV (1.2/50 μs); Test dielettrico: 2.5 kV / 1 min
  • Protezione dei terminali: IP20; fault current indicator provided
  • Ambiente: −25 °C … +55 °C (daily average ≤ 35 °C); Stoccaggio: −40 °C … +70 °C
  • Norme/Approvazioni: IEC/EN 61008-1; NF, ISI, UKCA, CE

Dati tecnici

StandardIEC/EN 61008-1
ModelloVFL002
Pali2P, 4P
Corrente nominale (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilità nominale (IΔn)10 mA (16–40 A), 30 mA, 100 mA, 300 mA
Tensione nominale (Ue)2P: 240 V~; 4P: 415 V~
Tensione di isolamento (Ui)500 V
Frequenza nominale50/60 Hz
Residuo nominale di fabbricazione e rottura (IΔm)500 A (In = 16-40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)
Cortocircuito condizionato (Inc = IΔc)6000 A, 10000 A
Waveform sensitivityAC, A, ASi
Tripping time classesIstantaneo / Breve ritardo (10-300 ms) / Selettivo S (150-500 ms)
Break time under IΔn (Normal)≤ 100 ms
Resistenza agli impulsi (Uimp)6 kV
Tensione di prova dielettrica2.5 kV (1 min at power frequency)
Grado di inquinamento2
Vita elettrica≥ 2000 operazioni
Vita meccanica≥ 2000 operazioni
Indicatore di corrente di guasto
Grado di protezione dei terminaliIP20
Ambient temperature (avg ≤ 35 °C)Da -25 °C a +55 °C
Temperatura di stoccaggioDa -40 °C a +70 °C
Collegamento dei terminaliCavo / sbarra di tipo Pin
Terminal size (cable, top/bottom)25–35 mm²; 18–3 / 18–2 AWG (per size class)
Terminal size (busbar, top/bottom)10/16 mm²; 18-8 / 18-5 AWG
Coppia di serraggio2,5 N-m (≈ 22 in-lbs)
MontaggioGuida DIN EN 60715 (35 mm), clip rapida
ConnessioneDall'alto e dal basso
ApprovazioniNF, ISI, UKCA, CE

Applicazioni

  • Quadri monofase che richiedono un rccb 2 poli device at 240 V~
  • Three-phase distribution using 4P at 415 V~ with coordinated upstream SCPD
  • Loads with electronics and frequent transients — use ASi high-immunity version

Certificazioni

Conforme a IEC/EN 61008-1; certified NF, ISI, UKCA, CE.

FAQ

When do I choose 2P vs 4P?

Use 2P for single-phase 240 V~ systems and 4P for three-phase 415 V~ systems.

What sensitivity should I select?

10/30 mA for additional personal protection; 100/300 mA for fire protection and selectivity.

How to coordinate conditional short-circuit rating?

Use an upstream breaker/fuse so the installation respects Inc = IΔc (6 kA / 10 kA) under fault conditions.

rccb 2 pole VFL002 Kuangya, 2P/4P 16–100A 10/30/100/300 mA

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “RCCB VFL002 — 2/4 Pole Residual Current Circuit Breaker”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *