Interruttore automatico tipo RCCB VFL005 - Protezione da corrente residua 2P e 4P

  • Circuit breaker RCCB type for reliable residual current protection in residential and industrial systems

  • Available in 2 pole & 4 pole versions, rated current options 16A to 100A, sensitivity from 30mA to 300mA

  • Compliant with IEC/EN 61008-1, featuring high short-circuit withstand capacity and compact installation

Richiedi un preventivo

Categoria:

Panoramica

Il VFL005 circuit breaker RCCB type provides effective protection against leakage current, electric shocks,
and fire hazards caused by ground faults. Designed with 2P and 4P configurations, it ensures reliable safety in both
residential and commercial installations. The unit complies with IEC/EN 61008-1 standard.

Caratteristiche principali

  • 2P and 4P residual current circuit breaker with rated currents from 16A to 100A
  • Sensitivity options: 30mA, 100mA, 300mA for flexible protection levels
  • Rated voltage: 2P up to 240V, 4P up to 415V
  • Short-circuit withstand capacity up to 10kA
  • High surge immunity up to 6kV
  • Test button for functional verification
  • Terminal protection degree: IP20
  • Operating temperature: −25°C to +55°C

Dati tecnici

StandardIEC/EN 61008-1
Pali2P, 4P
Corrente nominale In16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilità nominale IΔn30mA, 100mA, 300mA
Tensione nominale Ue2P: 240V / 4P: 415V
Frequenza nominale50/60Hz
Short-Circuit Capacity10kA
Tensione di tenuta agli impulsi6kV
Terminal Size for Cable25–35 mm²
Terminal ProtectionIP20
Vita meccanica≥ 2000 operazioni
Vita elettrica≥ 2000 operazioni
MontaggioDIN rail EN 60715 (35mm)

Applicazioni

The VFL005 circuit breaker RCCB type is suitable for residential, commercial, and industrial distribution systems.
Common applications include:

  • 2 pole RCCB for single-phase home distribution boards
  • 4 pole RCCB for three-phase industrial panels
  • Protection in offices, data centers, and critical facilities
  • Integration with other devices such as SPD DC,
    Fusibile CC, e Miniature Circuit Breakers

Certificazioni

  • IEC/EN 61008-1 compliance
  • CE certified
  • UKCA compliant
  • Direttiva RoHS

FAQ

What is the difference between a 2P and 4P RCCB?

2P RCCBs are used in single-phase systems, while 4P RCCBs are designed for three-phase systems. The choice depends on the type of installation.

Does the VFL005 circuit breaker RCCB type protect against overload?

No, RCCBs are intended for residual current (earth leakage) protection. Overcurrent and short-circuit protection require an MCB or MCCB in combination.

What are the available rated currents for VFL005?

The VFL005 supports 16A, 25A, 32A, 40A, 63A, 80A, and 100A configurations.

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “VFL005 Circuit Breaker RCCB Type – 2P & 4P Residual Current Protection”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *