240V Dispositivo di protezione contro le sovratensioni KYSPD-20T2+3-3P+1N | Kuangya

  • 240V surge protection device con 3+1 topology (L1-L2-L3-N) for 230/400 V AC networks.

  • Valori di sovratensione: In 10 kA (8/20 µs), Imax 20 kA (8/20 µs), Fino ≤ 0,3-1,8 kV in funzione di Uc.

  • Combines MOV + GDT technology for L–N and N–PE coordinated protection, pluggable modules, optional Contatti di segnalazione RC.

Richiedi un preventivo

Categoria:
The Kuangya KYSPD-20T2+3-3+1 is a 240V surge protection device designed for three-phase + neutral systems at 230/400 V AC. It uses a 3+1 topology, with MOV protection for L–N and coordinated GDT+MOV protection for N–PE, offering reliable suppression of transient overvoltages from lightning and switching surges.Its compact pluggable cartridge design allows easy replacement, while integrated thermal disconnectors ensure safe operation. Visual green/red indicators provide status feedback, and optional RC contacts enable remote fault monitoring.

Caratteristiche principali

  • Class II+III / Type 2+3 surge protection device with 3+1 topology.
  • Corrente di scarica nominale (In): 10 kA (8/20 μs).
  • Corrente di scarica massima (Imax): 20 kA (8/20 μs).
  • Livello di protezione dalla tensione (Up): ≤ 0,3-1,8 kV a seconda di Uc (75-440 V).
  • Response time: < 25 ns (L–N), < 100 ns (N–PE).
  • Fusibile di sicurezza: max 63 A gL/gG; ISCCR 10 kA AC.
  • Pluggable module, thermal disconnector, green/red fault status indicator.
  • Optional RC remote signaling contacts for BMS/PLC integration.
  • Custodia IP20, termoplastica UL94 V-0; temperatura di esercizio da -40 °C a +70 °C.
  • Montaggio su guida DIN (35 mm, EN 60715); conforme a IEC/EN 61643-11.

Specifiche tecniche

Codice prodottoKYSPD-20T2+3-3+1
Categoria240V surge protection device
Tensione nominale del sistema230/400 V CA
Topologia3+1 (L-N MOV, N-PE GDT+MOV)
Tensione operativa continua (Uc)75 / 150 / 275 / 320 / 385 / 440 V
Corrente di scarica nominale (In, 8/20 μs)10 kA
Corrente di scarica massima (Imax, 8/20 μs)20 kA
Livello di protezione della tensione (su)≤ 0,3-1,8 kV
Tempo di risposta< 25 ns (L–N), < 100 ns (N–PE)
Fusibile di riserva (max)63 A gL/gG
Corrente nominale di cortocircuito (ISCCR)10 kA CA
Temperatura di esercizioDa -40 °C a +70 °C
MontaggioGuida DIN da 35 mm, EN 60715
Involucro / ProtezioneTermoplastico UL94 V-0 / IP20
Segnalazione remota (RC)Opzionale; AC 250 V / 0,5 A; DC 250 V / 0,1 A; 125 V / 0,2 A; 75 V / 0,5 A
StandardIEC/EN 61643-11

Cablaggio e dimensioni

Connection diagram 240V surge protection device KYSPD-20T2+3-3+1

Connection diagram 240V surge protection device KYSPD-20T2+3-3+1

Dimensions 240V surge protection device KYSPD-20T2+3-3+1

Dimensions 240V surge protection device KYSPD-20T2+3-3+1

Applicazioni

  • Main distribution boards in residential and commercial buildings (240V systems).
  • Protection of elevators, industrial control systems, and sensitive electronics.
  • Panels requiring coordinated 3+1 surge protection in TT/TN-S networks.

FAQ

  • What topology does KYSPD-20T2+3-3+1 use? It uses 3+1 topology: L–N MOV, N–PE GDT+MOV.
  • Qual è la sua capacità di scarica di picco? In 10 kA, Imax 20 kA.
  • Where is it applied? In 230/400 V AC three-phase + N systems, especially 240V distribution panels.
  • Supporta il monitoraggio? Yes, optional RC contacts provide remote signaling.
  • What is the maximum back-up fuse rating? 63 A gL/gG.
Per informazioni dettagliate sui prezzi e sull'assistenza tecnica, consultare contattateci.Esplora altre soluzioni Kuangya: SPD DC, Protezione dalle sovratensioni CA.

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “240V Surge Protection Device KYSPD-20T2+3-3P+1N | Kuangya”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *