240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya

  • Four-pole 240v surge protection device (3+1) design for TN-S and TT systems.

  • Withstands Iimp 25 kA (10/350 μs) per pole, In 25 kA, Imax 100 kA.

  • Pluggable cartridge with indicator window; optional RC contacts; DIN rail mount.

Richiedi un preventivo

Categoria:
The Kuangya KYSPD-25T1-3+1 is a four-pole 240v surge protection device designed for electrical panels in 230/400 V AC systems. With its 3+1 configuration, it provides enhanced protection for phase-to-neutral and neutral-to-earth paths. This 240v surge protection device is tested according to IEC/EN 61643-11 and withstands lightning currents up to Iimp 25 kA per pole (10/350 μs). It is ideal for service entrance installations where reliable first-stage protection is required.

Caratteristiche principali

  • Complies with IEC/EN 61643-11, Class I / Type 1.
  • 3+1 configuration: three phases plus neutral-to-earth protection.
  • Iimp 25 kA (10/350 μs) per pole; In 25 kA; Imax 100 kA.
  • Nominal system voltage Uo/Un: 230/400 V AC; suitable as a 240v surge protection device.
  • Uc options: 320 / 385 / 440 V AC; voltage protection level (Up): ~1.6–2.0 kV.
  • Response time < 25 ns.
  • Pluggable replaceable cartridge with thermal disconnector and visual indicator.
  • Optional RC contacts for remote signaling.
  • Housing UL94 V-0 thermoplastic; IP20 built-in; DIN 35 mm rail mounting.

Specifiche tecniche

ParametroValore
Product CodeKYSPD-25T1-3+1
Category240V Surge Protection Device (Type 1 / Class I)
Nominal System Voltage (Uo/Un)230 / 400 V AC
Max. Continuous Operating Voltage (Uc)320 / 385 / 440 V AC
Nominal Discharge Current (In, 8/20 μs)25 kA
Max. Discharge Current (Imax, 8/20 μs)100 kA
Impulse Discharge Current (Iimp, 10/350 μs)25 kA per pole
Voltage Protection Level (Up)~1.6–2.0 kV
Tempo di risposta< 25 ns
Short-Circuit Current Rating (ISCCR)50 kA
Backup Fuse (max)315 A gL/gG
Temperatura di esercizio-40 °C … +70 °C
Montaggio35 mm DIN rail (EN 60715)
EnclosureThermoplastic, UL94 V-0
Protection DegreeIP20 (built-in)
Remote SignalingOptional RC contacts
StandardIEC 61643-11 / EN 61643-11

This 240v surge protection device is recommended for TN-S and TT earthing systems, delivering reliable first-stage lightning current handling.

Cablaggio e dimensioni

  • Connection diagram: kyspd-25t1-3+1-connection
  • 240v surge protection device 3+1 wiring diagram
  • Dimensions: kyspd-25t1-3+1-dimensions
  • 240v surge protection device 3+1 dimensions

Applicazioni

  • Service entrance protection for low-voltage panels.
  • First-stage 240v surge protection device in coordinated systems with Type 2 and Type 3 SPDs.
  • Commercial and industrial electrical panels requiring robust lightning protection.

FAQ

Where should KYSPD-25T1-3+1 be installed?

It should be installed at the service entrance or main panel as a 240v surge protection device.

What is the impulse discharge current rating?

Il 240v surge protection device withstands Iimp 25 kA per pole (10/350 μs).

Can this device be used in TT systems?

Yes, the 3+1 design makes it suitable for TT as well as TN-S systems.

How can the module be replaced?

The pluggable cartridge design makes this 240v surge protection device easy to service.

Does it support remote monitoring?

Sì, sono disponibili terminali RC opzionali per la segnalazione a distanza.

What standards does it comply with?

IEC/EN 61643-11 for AC surge protective devices.

Richiedi un preventivo · Related products: AC MCB, Interruttore di trasferimento manuale

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *