{"id":1571,"date":"2025-09-16T06:29:14","date_gmt":"2025-09-16T06:29:14","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1571"},"modified":"2025-09-22T09:08:21","modified_gmt":"2025-09-22T09:08:21","slug":"30ma-4-pole-rccb-vkl008","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/fr\/product\/30ma-4-pole-rccb-vkl008\/","title":{"rendered":"RCCB VKL008 - Disjoncteur \u00e0 courant r\u00e9siduel"},"content":{"rendered":"<div class=\"product-description\">\n<h2>Vue d'ensemble<\/h2>\n<p>The Kuangya VKL008 <strong>30ma 4 pole rccb<\/strong> detects earth leakage and disconnects the circuit to protect<br \/>\npeople and installations from electric shock and fire hazards caused by insulation faults. It is available in<br \/>\n2-pole and 4-pole versions for single-phase and three-phase distribution boards in residential, commercial,<br \/>\nand light-industrial environments.<\/p>\n<h2>Caract\u00e9ristiques principales<\/h2>\n<ul>\n<li><strong>P\u00f4les :<\/strong> 2P \/ 4P<\/li>\n<li><strong>Courant nominal (In) :<\/strong> 16, 25, 32, 40, 63, 80, 100 A<\/li>\n<li><strong>Sensibilit\u00e9 nominale (I\u0394n) :<\/strong> 10 \/ 30 \/ 100 \/ 300 mA<\/li>\n<li><strong>Tension nominale (Ue) :<\/strong> 240 V~ (2P) \/ 415 V~ (4P)<\/li>\n<li><strong>Tension d'isolation (Ui) :<\/strong> 500 V | \u00a0 <strong>Fr\u00e9quence :<\/strong> 50\/60 Hz<\/li>\n<li><strong>Rupture r\u00e9siduelle (I\u0394m) :<\/strong> up to 1000 A (per In group)<\/li>\n<li><strong>Court-circuit conditionnel (Inc = I\u0394c) :<\/strong> 6000 A \/ 10000 A (with upstream SCPD coordination)<\/li>\n<li><strong>Tripping behaviour:<\/strong> Instantaneous; short time delay (Si\/G\/KV); selective S<\/li>\n<li><strong>R\u00e9sistance \u00e0 l'impulsion (Uimp) :<\/strong> 6 kV ; <strong>Essai di\u00e9lectrique :<\/strong> 2,5 kV (1 min)<\/li>\n<li><strong>Protection des bornes :<\/strong> IP20 ; <strong>Couple de serrage :<\/strong> 2,5 N-m<\/li>\n<li><strong>Bornes et tailles :<\/strong> c\u00e2ble 25-35 mm\u00b2 ; barre de distribution \u00e0 broches 10\/16 mm\u00b2.<\/li>\n<li><strong>Montage :<\/strong> Rail DIN EN 60715 (35 mm) ; connexion sup\u00e9rieure\/inf\u00e9rieure<\/li>\n<\/ul>\n<h2>Donn\u00e9es techniques<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>Mod\u00e8le<\/th>\n<td>VKL008<\/td>\n<\/tr>\n<tr>\n<td>P\u00f4les<\/td>\n<td>2P, 4P<\/td>\n<\/tr>\n<tr>\n<td>Courant nominal (In)<\/td>\n<td>16A, 25A, 32A, 40A, 63A, 80A, 100A<\/td>\n<\/tr>\n<tr>\n<td>Sensibilit\u00e9 nominale (I\u0394n)<\/td>\n<td>10 mA, 30 mA, 100 mA, 300 mA<\/td>\n<\/tr>\n<tr>\n<td>Tension nominale (Ue)<\/td>\n<td>2P : 240 V~ ; 4P : 415 V~<\/td>\n<\/tr>\n<tr>\n<td>Tension d'isolation (Ui)<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence nominale<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>R\u00e9sidus de fabrication et de rupture (I\u0394m)<\/td>\n<td>up to 1000 A (per In group)<\/td>\n<\/tr>\n<tr>\n<td>Court-circuit conditionnel (Inc = I\u0394c)<\/td>\n<td>6000 A ; 10000 A (avec SCPD en amont)<\/td>\n<\/tr>\n<tr>\n<td>Temps de d\u00e9clenchement<\/td>\n<td>Instantaneous; short time delay; selective S (\u2264100 ms at I\u0394n for Normal)<\/td>\n<\/tr>\n<tr>\n<td>R\u00e9sistance \u00e0 l'impulsion (Uimp)<\/td>\n<td>6 kV<\/td>\n<\/tr>\n<tr>\n<td>Essai di\u00e9lectrique<\/td>\n<td>2.5 kV, 1 minute at power frequency<\/td>\n<\/tr>\n<tr>\n<td>Degr\u00e9 de protection des bornes<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Couple de serrage<\/td>\n<td>2,5 N-m<\/td>\n<\/tr>\n<tr>\n<td>Taille des bornes (c\u00e2ble)<\/td>\n<td>25-35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Taille des bornes (barre omnibus)<\/td>\n<td>10\/16 mm\u00b2 (pin-type busbar)<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Rail DIN EN 60715 (35 mm)<\/td>\n<\/tr>\n<tr>\n<td>Connexion<\/td>\n<td>Haut et bas<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"\/images\/rccb-vkl008.jpg\" alt=\"30ma 4 pole rccb VKL008 Kuangya 2P\/4P 16\u2013100A 10\/30\/100\/300 mA\" \/><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"237\" data-end=\"325\">\n<p data-start=\"239\" data-end=\"325\"><strong data-start=\"239\" data-end=\"259\">30ma 4 pole rccb<\/strong> for three-phase systems (2P version available for single-phase)<\/p>\n<\/li>\n<li data-start=\"326\" data-end=\"411\">\n<p data-start=\"328\" data-end=\"411\">In 16\u2013100 A; I\u0394n 10\/30\/100\/300 mA; Ue 240 V (2P) \/ 415 V (4P); Ui 500 V; 50\/60 Hz<\/p>\n<\/li>\n<li data-start=\"412\" data-end=\"488\">\n<p data-start=\"414\" data-end=\"488\">Uimp 6 kV; Inc = I\u0394c 6\/10 kA (with upstream SCPD); IP20; DIN-rail EN 60715<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1811,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-1571","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product\/1571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=1571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/1811"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=1571"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1571"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1571"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}