{"id":1558,"date":"2025-09-15T07:25:39","date_gmt":"2025-09-15T07:25:39","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1558"},"modified":"2025-09-22T07:59:06","modified_gmt":"2025-09-22T07:59:06","slug":"vrl01-02-03-rcbo-unipolaire","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/fr\/product\/vrl01-02-03-rcbo-single-pole\/","title":{"rendered":"VRL01 \/ VRL02 \/ VRL03 RCBO - Unipolaire + Neutre (1P+N) 6-50A"},"content":{"rendered":"<p><!-- Put the Focus KW at the very beginning --><\/p>\n<p><strong>rcbo unipolaire<\/strong> VRL01 \/ VRL02 \/ VRL03 integrates residual-current and overcurrent protection in a compact 1P+N format, rated 6\u201350 A for 240 V, 50\/60 Hz systems with Type AC\/A and multiple I\u0394n options.<\/p>\n<section id=\"overview\">\n<h2>Vue d'ensemble<\/h2>\n<p>The VRL01 \/ VRL02 \/ VRL03 family is designed for single-phase distribution branches where<br \/>\nreliable residual-current protection and coordinated overcurrent performance are required.<br \/>\nEach variant shares the same 1P+N footprint and broad current range up to 50 A, with<br \/>\nselectable tripping curves (B\/C), multiple residual sensitivities, and high breaking<br \/>\ncapacity options (6\/10 kA) to match fault levels on 240 V systems.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>Caract\u00e9ristiques principales<\/h2>\n<ul>\n<li>Facteur de forme : <strong>1P+N<\/strong> (single-pole + neutral)<\/li>\n<li>Courant nominal (In) : <strong>6\u201350 A<\/strong> (typical steps: 6\/10\/16\/20\/25\/32\/40\/50 A)<\/li>\n<li>Tension nominale (Ue) : <strong>240 V CA<\/strong>, 50\/60 Hz<\/li>\n<li>Type de courant r\u00e9siduel : <strong>Type AC \/ Type A<\/strong><\/li>\n<li>Sensibilit\u00e9s (I\u0394n) : <strong>10 \/ 30 \/ 100 \/ 300 mA<\/strong><\/li>\n<li>MCB tripping curves: <strong>B (3-5\u00d7In)<\/strong> et <strong>C (5-10\u00d7In)<\/strong><\/li>\n<li>Capacit\u00e9 de rupture (Icn) : <strong>6 kA \/ 10 kA<\/strong> @ 240 V<\/li>\n<li>Front test button (T); DIN-rail mounting; front wiring<\/li>\n<li>Compliance &amp; certification: <strong>IEC\/EN 61009-1<\/strong>; <strong>SEMKO, UKCA, CE<\/strong><\/li>\n<\/ul>\n<\/section>\n<section id=\"technical-data\">\n<h2>RCBO Single Pole Technical Data \u2014 VRL01 \/ VRL02 \/ VRL03<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tres<\/th>\n<th>VRL01<\/th>\n<th>VRL02<\/th>\n<th>VRL03<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>P\u00f4les<\/td>\n<td colspan=\"3\">1P+N (unipolaire + neutre)<\/td>\n<\/tr>\n<tr>\n<td>Courant nominal (In)<\/td>\n<td>6\u201350 A<\/td>\n<td>6\u201350 A<\/td>\n<td>6\u201350 A<\/td>\n<\/tr>\n<tr>\n<td>Tension nominale (Ue)<\/td>\n<td>240 V CA<\/td>\n<td>240 V CA<\/td>\n<td>240 V CA<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence<\/td>\n<td colspan=\"3\">50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Type de courant r\u00e9siduel<\/td>\n<td colspan=\"3\">Type AC \/ Type A<\/td>\n<\/tr>\n<tr>\n<td>Courant r\u00e9siduel nominal (I\u0394n)<\/td>\n<td colspan=\"3\">10 \/ 30 \/ 100 \/ 300 mA<\/td>\n<\/tr>\n<tr>\n<td>MCB tripping curve<\/td>\n<td colspan=\"3\">B : 3-5 \u00d7 In ; C : 5-10 \u00d7 In<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 de rupture (Icn)<\/td>\n<td>6 kA \/ 10 kA @ 240 V<\/td>\n<td>6 kA \/ 10 kA @ 240 V<\/td>\n<td>6 kA \/ 10 kA @ 240 V<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td colspan=\"3\">Rail DIN ; c\u00e2blage frontal ; bouton de test (T)<\/td>\n<\/tr>\n<tr>\n<td>Utilisation recommand\u00e9e<\/td>\n<td colspan=\"3\">Residential &amp; commercial branches (lighting \/ sockets) within 1P+N and \u226450 A<\/td>\n<\/tr>\n<tr>\n<td>Normes<\/td>\n<td colspan=\"3\">IEC\/EN 61009-1<\/td>\n<\/tr>\n<tr>\n<td>Certifications<\/td>\n<td colspan=\"3\">SEMKO, UKCA, CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"applications\">\n<h2>Applications<\/h2>\n<ul>\n<li>Apartments &amp; houses: lighting\/socket circuits up to 50 A<\/li>\n<li>Commercial offices &amp; retail: small-to-medium branch protection<\/li>\n<li>Public facilities: classrooms, admin areas, auxiliary circuits<\/li>\n<\/ul>\n<\/section>\n<section id=\"media\">&nbsp;<\/p>\n<\/section>\n<section id=\"certs\">\n<h2>Normes et conformit\u00e9<\/h2>\n<p>Conforms to <strong>IEC\/EN 61009-1<\/strong> with certifications <strong>SEMKO, UKCA, CE<\/strong>.<br \/>\nCoordinate with upstream protective devices; follow local codes for selectivity and fault levels.<\/p>\n<\/section>\n<section id=\"faq\">\n<h2>FAQ<\/h2>\n<details>\n<summary>Do VRL01, VRL02 and VRL03 differ in core protection features?<\/summary>\n<div>\n<p>All three share the same 1P+N format, 6\u201350 A range, Type AC\/A residual options and B\/C curves. They are part of the same platform with high breaking-capacity options (6\/10 kA) for 240 V systems.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>Which sensitivity (I\u0394n) should be used for sockets and lighting?<\/summary>\n<div>\n<p>30 mA is most common for socket\/lighting circuits. 10 mA is for higher touch-safety; 100\/300 mA may be used per coordination and local code requirements.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>How to choose between curve B and curve C?<\/summary>\n<div>\n<p>Utiliser la courbe B (3-5\u00d7In) pour les charges r\u00e9sistives\/l\u00e9g\u00e8rement inductives ; utiliser la courbe C (5-10\u00d7In) pour les circuits avec des appels de courant plus importants tels que les moteurs ou les transformateurs.<\/p>\n<\/div>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul data-start=\"381\" data-end=\"705\">\n<li data-start=\"381\" data-end=\"491\">\n<p data-start=\"383\" data-end=\"491\"><strong data-start=\"383\" data-end=\"410\">rcbo unipolaire (1P+N)<\/strong> modular RCBO for single-phase branches, <strong data-start=\"451\" data-end=\"463\">In 6\u201350A<\/strong>, tripping curves <strong data-start=\"481\" data-end=\"488\">B\/C<\/strong>.<\/p>\n<\/li>\n<li data-start=\"492\" data-end=\"603\">\n<p data-start=\"494\" data-end=\"603\"><strong data-start=\"494\" data-end=\"514\">Type AC \/ Type A<\/strong>, sensibilit\u00e9s <strong data-start=\"530\" data-end=\"560\">I\u0394n 10 \/ 30 \/ 100 \/ 300 mA<\/strong>; <strong data-start=\"562\" data-end=\"590\">Icn 6 kA \/ 10 kA @ 240 V<\/strong>, 50\/60 Hz.<\/p>\n<\/li>\n<li data-start=\"604\" data-end=\"705\">\n<p data-start=\"606\" data-end=\"705\">Certified <strong data-start=\"616\" data-end=\"637\">SEMKO \/ UKCA \/ CE<\/strong>; standard <strong data-start=\"648\" data-end=\"666\">IEC\/EN 61009-1<\/strong>; front test button, DIN-rail mounting.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1790,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[36],"product_tag":[],"class_list":{"0":"post-1558","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rcbo","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product\/1558","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=1558"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/1790"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=1558"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1558"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1558"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1558"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}