{"id":1488,"date":"2025-09-12T06:05:31","date_gmt":"2025-09-12T06:05:31","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1488"},"modified":"2025-09-12T06:13:47","modified_gmt":"2025-09-12T06:13:47","slug":"kgld-dual-power-automatic-transfer-switch","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/fr\/product\/kgld-dual-power-automatic-transfer-switch\/","title":{"rendered":"KGLD Commutateur de transfert automatique \u00e0 double puissance (20-3200A)"},"content":{"rendered":"<section id=\"overview\">\n<p data-start=\"275\" data-end=\"742\">Le <strong data-start=\"279\" data-end=\"337\">Commutateur de transfert automatique (ATS) double puissance de la s\u00e9rie KGLD<\/strong> est un outil fiable <strong data-start=\"352\" data-end=\"392\">commutateur de transfert automatique double puissance<\/strong> con\u00e7u pour la commutation entre l'alimentation principale et l'alimentation de secours ou entre le r\u00e9seau et le g\u00e9n\u00e9rateur.<br data-start=\"469\" data-end=\"472\" \/>Gr\u00e2ce \u00e0 sa conception compacte, \u00e0 sa vitesse de commutation \u00e9lev\u00e9e et \u00e0 sa conformit\u00e9 \u00e0 la norme IEC 60947-6-1, la s\u00e9rie KGLD garantit un fonctionnement stable dans les installations critiques.<br data-start=\"616\" data-end=\"619\" \/>Il offre un transfert automatique, un verrouillage \u00e9lectrique et m\u00e9canique, et une position \u201c0\u201d forc\u00e9e en option pour la maintenance.<\/p>\n<h3 data-start=\"744\" data-end=\"760\">Applications<\/h3>\n<ul data-start=\"761\" data-end=\"1044\">\n<li data-start=\"761\" data-end=\"826\">\n<p data-start=\"763\" data-end=\"826\">H\u00f4pitaux, banques et centres de donn\u00e9es n\u00e9cessitant une alimentation continue<\/p>\n<\/li>\n<li data-start=\"827\" data-end=\"898\">\n<p data-start=\"829\" data-end=\"898\">Installations industrielles utilisant <strong data-start=\"857\" data-end=\"886\">commutateur de transfert automatique<\/strong> \u00e9quipement<\/p>\n<\/li>\n<li data-start=\"899\" data-end=\"969\">\n<p data-start=\"901\" data-end=\"969\">B\u00e2timents r\u00e9sidentiels et commerciaux avec alimentation \u00e9lectrique \u00e0 double source<\/p>\n<\/li>\n<li data-start=\"970\" data-end=\"1044\">\n<p data-start=\"972\" data-end=\"1044\">Syst\u00e8mes de g\u00e9n\u00e9rateurs de secours avec <strong data-start=\"1002\" data-end=\"1042\">commutateur de transfert automatique double puissance<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1046\" data-end=\"1062\">Caract\u00e9ristiques principales<\/h3>\n<ul data-start=\"1063\" data-end=\"1528\">\n<li data-start=\"1063\" data-end=\"1141\">\n<p data-start=\"1065\" data-end=\"1141\">Large gamme de courant : 20-1600A, adapt\u00e9 \u00e0 diverses applications de commutation ATS<\/p>\n<\/li>\n<li data-start=\"1142\" data-end=\"1199\">\n<p data-start=\"1144\" data-end=\"1199\">Tension nominale de fonctionnement : AC400V, isolation jusqu'\u00e0 1000V<\/p>\n<\/li>\n<li data-start=\"1200\" data-end=\"1244\">\n<p data-start=\"1202\" data-end=\"1244\">Capacit\u00e9 de court-circuit \u00e9lev\u00e9e : jusqu'\u00e0 120 kA<\/p>\n<\/li>\n<li data-start=\"1245\" data-end=\"1291\">\n<p data-start=\"1247\" data-end=\"1291\">Commutation rapide : temps de conversion 0,45s-1,2s<\/p>\n<\/li>\n<li data-start=\"1292\" data-end=\"1344\">\n<p data-start=\"1294\" data-end=\"1344\">Conforme aux normes IEC 60947-6-1 \/ GB\/T14048.11 ATS<\/p>\n<\/li>\n<li data-start=\"1345\" data-end=\"1402\">\n<p data-start=\"1347\" data-end=\"1402\">Prise en charge des op\u00e9rations de transfert manuel et automatique<\/p>\n<\/li>\n<li data-start=\"1403\" data-end=\"1528\">\n<p data-start=\"1405\" data-end=\"1528\">Disponible dans les mod\u00e8les 3P et 4P, id\u00e9al pour la mise en place d'un syst\u00e8me d'alerte. <strong data-start=\"1447\" data-end=\"1487\">commutateur de transfert automatique double puissance<\/strong> pour les projets commerciaux et industriels<\/p>\n<\/li>\n<\/ul>\n<\/section>\n<section id=\"parameters\">\n<h2>Principaux param\u00e8tres techniques<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th>Courant nominal (A)<\/th>\n<th>Tension d'isolation nominale Ui (V)<\/th>\n<th>Tension nominale de tenue \u00e0 l'impulsion Uimp (kV)<\/th>\n<th>Tension de service nominale Ue (V)<\/th>\n<th>AC-31A Courant nominal (A)<\/th>\n<th>AC-35A Courant nominal (A)<\/th>\n<th>AC-33A Courant nominal (A)<\/th>\n<th>Capacit\u00e9 d'\u00e9valuation<\/th>\n<th>Capacit\u00e9 de rupture nominale<\/th>\n<th>Capacit\u00e9 nominale limit\u00e9e de court-circuit (kA)<\/th>\n<th>Courant nominal de courte dur\u00e9e (kA)<\/th>\n<th>Temps de conversion I\u2194II (s)<\/th>\n<th>Tension de contr\u00f4le<\/th>\n<th>Puissance de d\u00e9marrage du moteur (W)<\/th>\n<th>Puissance du moteur Normal (W)<\/th>\n<th>Poids (kg)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>20<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>63<\/td>\n<td>63<\/td>\n<td>63<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>325<\/td>\n<td>62<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>160<\/td>\n<td>160<\/td>\n<td>160<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>62<\/td>\n<td>8.8<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>62<\/td>\n<td>9.0<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>9<\/td>\n<td>0.6<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>74<\/td>\n<td>16.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>630<\/td>\n<td>630<\/td>\n<td>630<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>9<\/td>\n<td>0.6<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>74<\/td>\n<td>17.0<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>70<\/td>\n<td>13<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>90<\/td>\n<td>32.0<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>70<\/td>\n<td>26<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>36.0<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1250<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>100<\/td>\n<td>50<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>40.0<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1600<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>120<\/td>\n<td>50<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>43.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h2>C\u00e2blage du circuit principal<\/h2>\n<p>Le commutateur de transfert automatique KGLD offre plusieurs modes de c\u00e2blage en fonction de la conception du syst\u00e8me :<\/p>\n<ul>\n<li>Type de connexion \u00e9conomique (moins de 100A)<\/li>\n<li>Mode de connexion des bornes signal passif + feu actif (100-630A)<\/li>\n<li>Connexion enti\u00e8rement automatique (160-1600A)<\/li>\n<li>R\u00e9glage forc\u00e9 enti\u00e8rement automatique \u201c0\u201d (les deux sources sont d\u00e9connect\u00e9es)<\/li>\n<li>Mode de connexion de la sortie du signal du g\u00e9n\u00e9rateur<\/li>\n<li>Automatique + Manuel (t\u00e9l\u00e9commande)<\/li>\n<li>C\u00e2blage avec contr\u00f4leur (100-1600A)<\/li>\n<\/ul>\n<p><em>Des sch\u00e9mas de c\u00e2blage d\u00e9taill\u00e9s sont disponibles dans le catalogue des produits et doivent \u00eatre scrupuleusement respect\u00e9s lors de l'installation.<\/em><\/p>\n<\/section>\n<section id=\"standards\">\n<h2>Normes et conformit\u00e9<\/h2>\n<p>La s\u00e9rie KGLD est conforme aux normes internationales suivantes :<\/p>\n<ul>\n<li>IEC 60947-1 \/ GB\/T 14048.1 (Appareillage \u00e0 basse tension - R\u00e8gles g\u00e9n\u00e9rales)<\/li>\n<li>IEC 60947-3 \/ GB\/T 14048.3 (interrupteurs-sectionneurs, isolateurs, combin\u00e9s-fusibles)<\/li>\n<li>IEC 60947-6-1 \/ GB\/T 14048.11 (\u00c9quipement de commutation de transfert automatique - ATS)<\/li>\n<li>Certifi\u00e9 pour la s\u00e9curit\u00e9, la performance et la long\u00e9vit\u00e9<\/li>\n<\/ul>\n<\/section>\n<section id=\"selection-guide\">\n<h2>Guide de s\u00e9lection<\/h2>\n<p>Lorsque vous choisissez un commutateur de transfert automatique KGLD, tenez compte des facteurs suivants :<\/p>\n<ol>\n<li><strong>Courant nominal (20A-1600A)<\/strong> \u2192 S\u00e9lection en fonction de la charge totale.<\/li>\n<li><strong>P\u00f4les<\/strong> \u2192 3P pour les syst\u00e8mes triphas\u00e9s \u00e0 trois fils, 4P pour les syst\u00e8mes triphas\u00e9s \u00e0 quatre fils.<\/li>\n<li><strong>M\u00e9thode de contr\u00f4le<\/strong> \u2192 Automatique ou manuel ; t\u00e9l\u00e9commande en option.<\/li>\n<li><strong>Temps de conversion<\/strong> \u2192 0,45s-1,2s selon le mod\u00e8le.<\/li>\n<li><strong>Capacit\u00e9 de court-circuit<\/strong> \u2192 Jusqu'\u00e0 120 kA pour les puissances sup\u00e9rieures.<\/li>\n<li><strong>M\u00e9thode d'installation<\/strong> \u2192 Poign\u00e9e mont\u00e9e sur panneau ou sur porte.<\/li>\n<li><strong>Normes et certification<\/strong> \u2192 V\u00e9rifier la conformit\u00e9 CEI\/GB et la conformit\u00e9 du projet.<\/li>\n<\/ol>\n<\/section>\n<section id=\"faq\">\n<h2>FAQ<\/h2>\n<details>\n<summary>Quelle est la principale diff\u00e9rence entre les s\u00e9ries KGLD et KGQ2 ?<\/summary>\n<p>Le KGLD est un ATS automatique motoris\u00e9 avec une large gamme de courant (20-1600A), tandis que le KGQ2 se concentre sur les interrupteurs de puissance doubles \u00e0 bo\u00eetier moul\u00e9 avec des applications diff\u00e9rentes.<\/p>\n<\/details>\n<details>\n<summary>Le KGLD peut-il \u00eatre utilis\u00e9 avec un g\u00e9n\u00e9rateur de secours ?<\/summary>\n<p>Oui, il prend en charge le transfert du r\u00e9seau au g\u00e9n\u00e9rateur, avec d\u00e9tection automatique de la tension et commutation s\u00e9curis\u00e9e.<\/p>\n<\/details>\n<details>\n<summary>Le KGLD prend-il en charge la commande \u00e0 distance ?<\/summary>\n<p>Oui, les modes de c\u00e2blage comprennent la t\u00e9l\u00e9commande manuelle et le fonctionnement bas\u00e9 sur un contr\u00f4leur pour les syst\u00e8mes intelligents.<\/p>\n<\/details>\n<details>\n<summary>Quelle est la dur\u00e9e de vie du KGLD ?<\/summary>\n<p>Endurance m\u00e9canique \u22658000 op\u00e9rations, endurance \u00e9lectrique \u22656000 op\u00e9rations dans les conditions nominales.<\/p>\n<\/details>\n<details>\n<summary>Est-il certifi\u00e9 ?<\/summary>\n<p>Oui, conforme aux normes IEC 60947-6-1, IEC 60947-3, GB\/T14048.11 et autres normes connexes.<\/p>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Le commutateur de transfert automatique (ATS) isol\u00e9 \u00e0 double puissance de la s\u00e9rie KGLD de Kuangya, couvrant 20A-3200A, est con\u00e7u pour un changement fiable de r\u00e9seau \u00e9lectrique \u2194 g\u00e9n\u00e9rateur.<\/p>\n<p>Il se caract\u00e9rise par une commutation rapide, un contr\u00f4leur ATS int\u00e9gr\u00e9, un m\u00e9canisme d'entra\u00eenement du moteur, une r\u00e9sistance di\u00e9lectrique \u00e9lev\u00e9e et une dur\u00e9e de vie de &gt;8000 op\u00e9rations.<\/p>\n<p>Convient aux h\u00f4pitaux, aux banques, aux immeubles de grande hauteur, aux installations industrielles et \u00e0 d'autres applications critiques n\u00e9cessitant une alimentation \u00e9lectrique ininterrompue.<\/p>","protected":false},"featured_media":1491,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[32],"product_tag":[],"class_list":{"0":"post-1488","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-transfer-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product\/1488","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=1488"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/1491"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=1488"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1488"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1488"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1488"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}