{"id":1369,"date":"2025-09-10T07:16:08","date_gmt":"2025-09-10T07:16:08","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1369"},"modified":"2025-09-16T09:48:09","modified_gmt":"2025-09-16T09:48:09","slug":"surge-protective-device-type-2-kyspd-40t2-2p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/fr\/product\/surge-protective-device-type-2-kyspd-40t2-2p\/","title":{"rendered":"Dispositif de protection contre les surtensions de type 2 KYSPD-40T2-2P | Kuangya"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-40T2-2P is a two-pole <strong>dispositif de protection contre les surtensions de type 2<\/strong><br \/>\ndesigned for single-phase AC systems at 230 V. It provides coordinated protection<br \/>\nfor L and N conductors against transient overvoltages from switching operations<br \/>\nand indirect lightning strikes.Built with high-energy MOV technology, this SPD delivers reliable protection in<br \/>\nresidential, commercial, and light industrial applications. It features pluggable<br \/>\nmodules for easy maintenance, a thermal disconnector with green\/red fault indicator,<br \/>\nand optional remote contacts for monitoring integration with BMS or PLC systems.<\/p>\n<\/section>\n<section id=\"features\">\n<h3>Caract\u00e9ristiques principales<\/h3>\n<ul>\n<li>Class II \/ Type 2 surge protective device (2P, L+N).<\/li>\n<li>Courant de d\u00e9charge nominal (In) : 20 kA (8\/20 \u03bcs).<\/li>\n<li>Courant de d\u00e9charge maximal (Imax) : 40 kA (8\/20 \u03bcs).<\/li>\n<li>Voltage protection level (Up): \u2264 1.3\u20132.0 kV depending on variant.<\/li>\n<li>Response time &lt; 25 ns for fast transient suppression.<\/li>\n<li>Max back-up fuse: 125 A gL\/gG; ISCCR 25 kA AC.<\/li>\n<li>Pluggable, serviceable cartridges with visible fault indicator (green\/red).<\/li>\n<li>Contacts de signalisation RC en option : AC 250 V \/ 0,5 A ; DC 250 V \/ 0,1 A ; 125 V \/ 0,2 A ; 75 V \/ 0,5 A.<\/li>\n<li>Bo\u00eetier thermoplastique UL94-V0, IP20 ; temp\u00e9rature de fonctionnement -40 \u00b0C \u00e0 +80 \u00b0C.<\/li>\n<li>Montage sur rail DIN (35 mm, EN 60715) ; conforme \u00e0 IEC\/EN 61643-11.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>Sp\u00e9cifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Code produit<\/th>\n<td>KYSPD-40T2-2P<\/td>\n<\/tr>\n<tr>\n<th>Cat\u00e9gorie<\/th>\n<td>Surge protective device type 2<\/td>\n<\/tr>\n<tr>\n<th>Tension nominale du syst\u00e8me<\/th>\n<td>230 V AC<\/td>\n<\/tr>\n<tr>\n<th>P\u00f4les<\/th>\n<td>2P (L+N)<\/td>\n<\/tr>\n<tr>\n<th>Tension de fonctionnement continu (Uc)<\/th>\n<td>230 V \/ 320 V \/ 385 V<\/td>\n<\/tr>\n<tr>\n<th>Courant de d\u00e9charge nominal (In, 8\/20 \u03bcs)<\/th>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<th>Courant de d\u00e9charge maximal (Imax, 8\/20 \u03bcs)<\/th>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<th>Niveau de protection de la tension (vers le haut)<\/th>\n<td>\u2264 1,3-2,0 kV<\/td>\n<\/tr>\n<tr>\n<th>Temps de r\u00e9ponse<\/th>\n<td>&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<th>Fusible de secours (max)<\/th>\n<td>125 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<th>Courant nominal de court-circuit (ISCCR)<\/th>\n<td>25 kA AC<\/td>\n<\/tr>\n<tr>\n<th>Temp\u00e9rature de fonctionnement<\/th>\n<td>De -40 \u00b0C \u00e0 +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Montage<\/th>\n<td>Rail DIN 35 mm, EN 60715<\/td>\n<\/tr>\n<tr>\n<th>Enceinte \/ Protection<\/th>\n<td>Thermoplastique UL94 V-0 \/ IP20<\/td>\n<\/tr>\n<tr>\n<th>Signalisation \u00e0 distance (RC)<\/th>\n<td>En option ; AC 250 V \/ 0,5 A ; DC 250 V \/ 0,1 A ; 125 V \/ 0,2 A ; 75 V \/ 0,5 A<\/td>\n<\/tr>\n<tr>\n<th>Normes<\/th>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>C\u00e2blage et dimensions<\/h3>\n<p>Connection diagram surge protective device type 2 KYSPD-40T2-2P<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1371\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-2P-wiring-diagram-275x300.png\" alt=\"Connection diagram surge protective device type 2 KYSPD-40T2-2P\" width=\"400\" height=\"436\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-2P-wiring-diagram-275x300.png 275w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-2P-wiring-diagram-300x328.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-2P-wiring-diagram.png 478w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<p>Dimensions surge protective device type 2 KYSPD-40T2-2P<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1372\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-2P-dimension-300x257.png\" alt=\"Dimensions surge protective device type 2 KYSPD-40T2-2P\" width=\"400\" height=\"343\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-2P-dimension-300x257.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-2P-dimension.png 484w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<\/section>\n<section id=\"applications\">\n<h3>Applications<\/h3>\n<ul>\n<li>Single-phase 230 V AC distribution panels in residential and commercial sites.<\/li>\n<li>Coordination with upstream Type 1 arresters in TT\/TN networks.<\/li>\n<li>Panels requiring reliable 2P surge protection with optional RC monitoring.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>FAQ<\/h3>\n<ul>\n<li><strong>Quelle est la classe du DOCUP KYSPD-40T2-2P ?<\/strong> Il est de classe II, type 2, conform\u00e9ment \u00e0 la norme IEC\/EN 61643-11.<\/li>\n<li><strong>Quelle est sa capacit\u00e9 de d\u00e9charge ?<\/strong> In 20 kA, Imax 40 kA.<\/li>\n<li><strong>Can it be used in single-phase systems?<\/strong> Yes, it is designed for 230 V AC L+N applications.<\/li>\n<li><strong>Prend-il en charge la signalisation \u00e0 distance ?<\/strong> Oui, des contacts RC sont disponibles en option.<\/li>\n<li><strong>Quel est le calibre maximum du fusible de secours ?<\/strong> 125 A gL\/gG.<\/li>\n<\/ul>\n<\/section>\n<section id=\"cta\">Pour une tarification d\u00e9taill\u00e9e et une assistance technique, veuillez <a href=\"\/fr\/contact-us\/\">nous contacter<\/a>.D\u00e9couvrez d'autres produits Kuangya : <a href=\"\/fr\/dc-spd\/\">DC SPD<\/a>, <a href=\"\/fr\/ac-surge-protective-device\/\">Protection contre les surtensions en courant alternatif<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"596\" data-end=\"702\">\n<p data-start=\"598\" data-end=\"702\"><strong data-start=\"598\" data-end=\"632\">Dispositif de protection contre les surtensions de type 2<\/strong> pour <strong data-start=\"637\" data-end=\"662\">230 V AC single-phase<\/strong> syst\u00e8mes avec <strong data-start=\"676\" data-end=\"699\">L+N protection (2P)<\/strong>.<\/p>\n<\/li>\n<li data-start=\"703\" data-end=\"860\">\n<p data-start=\"705\" data-end=\"860\">Courant de d\u00e9charge nominal <strong data-start=\"729\" data-end=\"751\">En 20 kA (8\/20 \u00b5s)<\/strong>, D\u00e9charge maximale <strong data-start=\"771\" data-end=\"795\">Imax 40 kA (8\/20 \u00b5s)<\/strong>; niveau de protection de la tension <strong data-start=\"822\" data-end=\"841\">Jusqu'\u00e0 \u2264 1,3-2,0 kV<\/strong> en fonction de Uc.<\/p>\n<\/li>\n<li data-start=\"861\" data-end=\"977\">\n<p data-start=\"863\" data-end=\"977\">Pluggable design, thermal disconnector with fault indicator, optional <strong data-start=\"933\" data-end=\"955\">Contacts \u00e0 distance RC<\/strong>, Montage sur rail DIN.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1580,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1369","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product\/1369","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=1369"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/1580"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=1369"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1369"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1369"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1369"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}