{"id":1320,"date":"2025-09-09T15:41:45","date_gmt":"2025-09-09T15:41:45","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1320"},"modified":"2025-12-01T06:51:57","modified_gmt":"2025-12-01T06:51:57","slug":"surge-protection-device-for-elevators","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/fr\/product\/surge-protection-device-for-elevators\/","title":{"rendered":"Dispositif de protection contre les surtensions pour ascenseurs KYSPD-7T1+2-3P+1 | Kuangya"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-7T1+2-3+1 is a specialized four-pole (3+1) <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong>. Elevators and lifts require highly reliable protection against power surges to avoid downtime and costly repairs. This <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong> combines Type 1 and Type 2 protection in one unit, safely discharging both lightning currents and transient switching surges, ensuring uninterrupted operation of elevator systems.<\/section>\n<section id=\"features\">\n<h3>Caract\u00e9ristiques principales<\/h3>\n<ul>\n<li>Conforme \u00e0 la norme IEC\/EN 61643-11, offrant une protection de classe I et de classe II.<\/li>\n<li>3+1 configuration: three-phase plus dedicated neutral-to-earth protection.<\/li>\n<li>Iimp 7 kA (10\/350 \u03bcs) par p\u00f4le ; In 20 kA ; Imax 40 kA.<\/li>\n<li>Uc: 275 V AC; nominal system voltage: 230\/400 V AC.<\/li>\n<li>Niveau de protection de la tension (Up) : \u2264 1,5 kV.<\/li>\n<li>Temps de r\u00e9ponse rapide &lt; 25 ns.<\/li>\n<li>Compact pluggable cartridge with thermal disconnector and visual status window.<\/li>\n<li>Optional RC contacts for remote status monitoring in elevator control rooms.<\/li>\n<li>Bo\u00eetier : Thermoplastique UL94 V-0 ; IP20 int\u00e9gr\u00e9 ; montage sur rail DIN 35 mm.<\/li>\n<li>Fiable <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong> in residential, commercial, and high-rise buildings.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>Sp\u00e9cifications<\/h3>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tres<\/th>\n<th>Valeur<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Code produit<\/td>\n<td>KYSPD-7T1+2-3+1<\/td>\n<\/tr>\n<tr>\n<td>Cat\u00e9gorie<\/td>\n<td>Surge Protection Device for Elevators<\/td>\n<\/tr>\n<tr>\n<td>Tension nominale du syst\u00e8me<\/td>\n<td>230\/400 V AC<\/td>\n<\/tr>\n<tr>\n<td>Tension de fonctionnement continu (Uc) Tension de fonctionnement continu (Uc)<\/td>\n<td>275 V AC<\/td>\n<\/tr>\n<tr>\n<td>Courant de d\u00e9charge par impulsion (Iimp, 10\/350 \u03bcs)<\/td>\n<td>7 kA par p\u00f4le<\/td>\n<\/tr>\n<tr>\n<td>Courant de d\u00e9charge nominal (In, 8\/20 \u03bcs)<\/td>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<td>Courant de d\u00e9charge max. Courant de d\u00e9charge (Imax, 8\/20 \u03bcs)<\/td>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<td>Niveau de protection de la tension (vers le haut)<\/td>\n<td>\u2264 1,5 kV<\/td>\n<\/tr>\n<tr>\n<td>Temps de r\u00e9ponse<\/td>\n<td>&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<td>Fusible de secours (max)<\/td>\n<td>125 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<td>Courant nominal de court-circuit (ISCCR)<\/td>\n<td>25 kA<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement<\/td>\n<td>-40 \u00b0C ... +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Rail DIN 35 mm (EN 60715)<\/td>\n<\/tr>\n<tr>\n<td>Logement<\/td>\n<td>Thermoplastique UL94 V-0<\/td>\n<\/tr>\n<tr>\n<td>Degr\u00e9 de protection<\/td>\n<td>IP20 (int\u00e9gr\u00e9)<\/td>\n<\/tr>\n<tr>\n<td>Signalisation \u00e0 distance<\/td>\n<td>Contacts RC en option<\/td>\n<\/tr>\n<tr>\n<td>Normes<\/td>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Le pr\u00e9sent <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong> ensures safe and continuous operation of elevator drives, controllers, and communication circuits by eliminating transient overvoltages.<\/p>\n<\/section>\n<section id=\"wiring\">\n<h3>C\u00e2blage et dimensions<\/h3>\n<ul>\n<li>Sch\u00e9ma de connexion : <em>kyspd-7t1+2-3+1-connection<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1323\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-wiring-diagram-287x300.png\" alt=\"surge protection device for elevators wiring diagram\" width=\"400\" height=\"418\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-wiring-diagram-287x300.png 287w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-wiring-diagram-300x314.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-wiring-diagram.png 444w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/li>\n<li>Dimensions : <em>kyspd-7t1+2-3+1-dimensions<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1322\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-dimension-300x230.png\" alt=\"surge protection device for elevators dimensions\" width=\"400\" height=\"307\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-dimension-300x230.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYSPD-7T12-3P1-dimension.png 496w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/li>\n<\/ul>\n<\/section>\n<section id=\"apps\">\n<h3>Applications<\/h3>\n<ul>\n<li>Main distribution boards feeding elevator systems.<\/li>\n<li>Dedicated <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong> in residential towers and commercial buildings.<\/li>\n<li>Ensures uninterrupted lift operation in high-rise and industrial facilities.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>FAQ<\/h3>\n<details>\n<summary>Why do elevators need surge protection?<\/summary>\n<p>Elevators include sensitive controllers and drives that are vulnerable to overvoltages. A <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong> prevents damage and downtime.<\/p>\n<\/details>\n<details>\n<summary>Where should KYSPD-7T1+2-3+1 be installed?<\/summary>\n<p>It should be installed in the distribution board that powers the elevator system.<\/p>\n<\/details>\n<details>\n<summary>Does it protect both phase and neutral conductors?<\/summary>\n<p>Yes, the 3+1 design makes this <strong>dispositif de protection contre les surtensions pour les ascenseurs<\/strong> effective for both phase-to-neutral and neutral-to-earth protection.<\/p>\n<\/details>\n<details>\n<summary>Can it be monitored remotely?<\/summary>\n<p>Yes, optional RC contacts allow integration into building management systems for elevator monitoring.<\/p>\n<\/details>\n<details>\n<summary>Quelles sont les normes auxquelles il r\u00e9pond ?<\/summary>\n<p>IEC\/EN 61643-11 pour les dispositifs de protection contre les surtensions.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta\"><a href=\"\/fr\/contact-us\/\">Obtenir un devis<\/a> - En rapport : <a href=\"\/fr\/ac-mcb\/\">AC MCB<\/a>, <a href=\"\/fr\/manual-transfer-switch\/\">Commutateur de transfert manuel<\/a><\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"248\" data-end=\"356\">\n<p data-start=\"250\" data-end=\"356\">Four-pole (3+1) <strong data-start=\"266\" data-end=\"307\">dispositif de protection contre les surtensions pour les ascenseurs<\/strong>, protecting both phase and neutral conductors.<\/p>\n<\/li>\n<li data-start=\"357\" data-end=\"414\">\n<p data-start=\"359\" data-end=\"414\">Iimp 7 kA (10\/350 \u03bcs) per pole, In 20 kA, Imax 40 kA.<\/p>\n<\/li>\n<li data-start=\"415\" data-end=\"516\">\n<p data-start=\"417\" data-end=\"516\">Pluggable design with LED status indicator, thermal disconnector, and optional RC remote signaling.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1592,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1320","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product\/1320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=1320"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/1592"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=1320"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1320"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1320"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}