{"id":4853,"date":"2026-10-28T11:39:40","date_gmt":"2026-10-28T03:39:40","guid":{"rendered":"https:\/\/cnkuangya.com\/?p=4853"},"modified":"2026-10-28T11:39:46","modified_gmt":"2026-10-28T03:39:46","slug":"heat-pump-rcd-type-a-f-b","status":"publish","type":"post","link":"https:\/\/cnkuangya.com\/fr\/blog\/heat-pump-rcd-type-a-f-b\/","title":{"rendered":"Quel interrupteur diff\u00e9rentiel pour une pompe \u00e0 chaleur ? Type A vs Type F vs Type B"},"content":{"rendered":"<p><strong>R\u00e9ponse rapide :<\/strong> There is no single RCD type for every heat pump. Type A may be specified for some units and jurisdictions; Type F can be appropriate for certain single-phase inverter-driven heat pumps that may produce composite residual currents; and Type B may be needed where smooth DC residual current can occur. Start with the exact heat-pump installation manual and local electrical rules, then match the RCD to the expected fault-current waveform.<\/p>\n<p>The words <em>heat pump<\/em> do not tell you whether the compressor drive is single-phase or three-phase, whether DC fault monitoring is built in, or which protective device the manufacturer tested. Those details decide the selection.<\/p>\n<h2>Why Does RCD Type Matter for a Heat Pump?<\/h2>\n<p>A residual-current device detects current leaving the intended circuit path and disconnects under specified conditions. An inverter-driven heat pump may create residual-current waveforms different from a simple resistive heater. Selecting the wrong detection type can leave a fault waveform outside the device&#8217;s intended capability; choosing a different type without checking the equipment can also cause unnecessary cost or unwanted trips.<\/p>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/6998\" rel=\"noopener\">IEC 62423<\/a> defines additional requirements and tests for Type F and Type B RCDs. Schneider Electric&#8217;s <a href=\"https:\/\/ckm-content.se.com\/ckmContent\/sfc\/servlet.shepherd\/document\/download\/0691H00000HrAOQQA3\" rel=\"noopener\">technical paper on RCD types<\/a> uses a single-phase heat pump with a variable-speed drive as an example of an application that may produce composite residual current.<\/p>\n<h2>Type A vs Type F vs Type B: What Changes?<\/h2>\n<table>\n<thead>\n<tr>\n<th>Type de RCD<\/th>\n<th>Relevant detection capability<\/th>\n<th>Heat-pump selection question<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Type A<\/td>\n<td>Sinusoidal AC and pulsating DC residual current<\/td>\n<td>Does the equipment manual permit Type A for this exact circuit and installation?<\/td>\n<\/tr>\n<tr>\n<td>Type F<\/td>\n<td>Type A capability plus specified composite residual currents associated with single-phase frequency converters<\/td>\n<td>Is the heat pump a suitable single-phase inverter application, and does the manual call for Type F?<\/td>\n<\/tr>\n<tr>\n<td>Type B<\/td>\n<td>Includes smooth DC residual-current detection within its specified range<\/td>\n<td>Can the equipment produce smooth DC fault current, or does its manual require Type B?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Type F is <strong>pas<\/strong> a substitute for Type B when smooth DC fault-current detection is required. Type B is also not an automatic upgrade for every heat pump. The connected equipment and applicable rules determine the correct device.<\/p>\n<h2>Single-Phase Inverter Heat Pumps: When Type F Enters the Discussion<\/h2>\n<p>A single-phase frequency converter can produce composite residual currents. IEC 62423 describes Type F devices for installations where frequency inverters are supplied between phase and neutral (or an earthed middle conductor). This makes Type F a relevant option to investigate for some single-phase inverter heat pumps.<\/p>\n<p>That does not mean every single-phase heat pump requires Type F. For example, <a href=\"https:\/\/www.nsw.gov.au\/housing-and-construction\/compliance-and-regulation\/electricians\/electrical-standards-rules-and-notes\/heat-pump-installations-for-electrical-work\" rel=\"noopener\">New South Wales government guidance for heat-pump hot-water installations<\/a> specifies Type A under its stated local rules. The equipment manufacturer and the installation jurisdiction must be checked together.<\/p>\n<h2>Three-Phase Units and Smooth DC Risk<\/h2>\n<p>Some three-phase drive arrangements may create residual-current components that a Type A or Type F device is not intended to detect. The drive topology, fault path and any integrated monitoring matter more than a simple \u201cthree-phase equals Type B\u201d slogan. If the heat-pump manual calls for Type B, do not substitute another type solely to reduce cost.<\/p>\n<p>Schneider Electric&#8217;s <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/RCDs_selection_in_presence_of_DC_earth_leakage_currents\" rel=\"noopener\">RCD selection guide for DC earth leakage<\/a> explains why DC components can affect RCD selection and upstream coordination. A qualified designer should also check whether an upstream RCD could be exposed to DC residual current from the heat-pump circuit.<\/p>\n<h2>RCCB or RCBO for a Heat Pump?<\/h2>\n<p>RCD <em>type<\/em> describes residual-current detection. It does not answer whether the circuit should use an RCCB with a separate overcurrent protective device or an RCBO combining residual-current and overcurrent protection. That choice depends on circuit design, breaker rating, discrimination and the available panel space. See our <a href=\"https:\/\/cnkuangya.com\/fr\/blog\/how-to-choose-rcbo\/\">RCBO type and rating guide<\/a> et <a href=\"https:\/\/cnkuangya.com\/fr\/rcbo\/\">RCBO product range<\/a>.<\/p>\n<p>Do not use the compressor&#8217;s rated power alone to choose the RCD&#8217;s current rating, residual operating current or trip curve. Check the manufacturer&#8217;s electrical data, starting behavior, conductor protection, and applicable installation standard.<\/p>\n<h2>Seven Checks Before Ordering<\/h2>\n<ol>\n<li><strong>Exact heat-pump model:<\/strong> obtain the current installation manual, not only a sales brochure.<\/li>\n<li><strong>Supply arrangement:<\/strong> confirm voltage, phases, neutral and earthing system.<\/li>\n<li><strong>Required RCD type:<\/strong> look for an explicit Type A, F or B instruction and any integrated DC monitoring.<\/li>\n<li><strong>Residual-current sensitivity:<\/strong> follow local requirements and the equipment manufacturer&#8217;s instructions.<\/li>\n<li><strong>Normal leakage:<\/strong> evaluate the total leakage of the heat pump and other loads on the same RCD.<\/li>\n<li><strong>Overcurrent protection:<\/strong> coordinate the RCCB\/RCBO with the conductor and prospective fault current.<\/li>\n<li><strong>Upstream coordination:<\/strong> check the effect of DC components and the selectivity of devices in series.<\/li>\n<\/ol>\n<p>For a wider discussion of RCD types and selectivity, read our <a href=\"https:\/\/cnkuangya.com\/fr\/blog\/2026-guide-to-rcd-coordination-in-european-residential-panels\/\">residential RCD coordination guide<\/a>. When requesting a quotation, send the model manual, supply details, required poles, desired device type, current rating, residual-current sensitivity and destination-market standard to <a href=\"https:\/\/cnkuangya.com\/fr\/contact-us\/\">KUANGYA<\/a>. This lets the supplier check the exact model rather than suggesting a device from the phrase \u201cheat pump\u201d alone.<\/p>\n<h2>FAQ<\/h2>\n<h3>Can I use a Type A RCD for a heat pump?<\/h3>\n<p>Possibly. Some equipment instructions and local rules specify Type A. Confirm the exact model, residual-current characteristics and jurisdiction before selection.<\/p>\n<h3>Is Type F always better than Type A?<\/h3>\n<p>No. Type F adds specified composite-current detection for relevant single-phase inverter applications, but the heat pump&#8217;s instructions and local rules decide whether it is needed and permitted.<\/p>\n<h3>Does Type F detect smooth DC faults like Type B?<\/h3>\n<p>No. Type F&#8217;s ability to tolerate a limited superimposed smooth DC component is not the same as Type B smooth DC residual-current detection.<\/p>\n<h3>Will a different RCD type fix repeated nuisance tripping?<\/h3>\n<p>Not necessarily. First check wiring, actual leakage, moisture, equipment faults, shared neutrals and the manufacturer&#8217;s protective-device requirements. Changing type without diagnosing the cause may leave the problem unresolved.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quel type de DDR est n\u00e9cessaire pour une pompe \u00e0 chaleur ? Comparez les types A, F et B pour les unit\u00e9s \u00e0 variateur de vitesse, puis v\u00e9rifiez le manuel, le courant de d\u00e9faut et les r\u00e9glementations locales avant de commander.<\/p>","protected":false},"author":4,"featured_media":4860,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[35,47],"tags":[],"class_list":["post-4853","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-rcd-leakage-protection"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/4853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=4853"}],"version-history":[{"count":2,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/4853\/revisions"}],"predecessor-version":[{"id":4862,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/4853\/revisions\/4862"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/4860"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=4853"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/categories?post=4853"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/tags?post=4853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}