{"id":2279,"date":"2025-12-15T09:19:15","date_gmt":"2025-12-15T09:19:15","guid":{"rendered":"https:\/\/cnkuangya.com\/?p=2279"},"modified":"2025-12-16T01:50:46","modified_gmt":"2025-12-16T01:50:46","slug":"matching-pv-combiner-box","status":"publish","type":"post","link":"https:\/\/cnkuangya.com\/fr\/blog\/matching-pv-combiner-box\/","title":{"rendered":"Correspondance entre les valeurs nominales de courant et de tension des bo\u00eetiers combin\u00e9s PV"},"content":{"rendered":"<p>In a solar photovoltaic (PV) system, the combiner box plays a central role in consolidating power and ensuring safety. It&#8217;s a junction box where the output of multiple solar strings are connected in parallel, combining their current before sending it to the inverter. More importantly, it houses the critical overcurrent protection devices (fuses or circuit breakers) that protect the system&#8217;s wiring and components from potentially dangerous faults.<img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"1118\" class=\"wp-image-2282\" style=\"width: 750px;\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-scaled.jpg\" alt=\"\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-scaled.jpg 1717w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-201x300.jpg 201w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-687x1024.jpg 687w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-768x1145.jpg 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-1030x1536.jpg 1030w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-1374x2048.jpg 1374w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-8x12.jpg 8w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-300x447.jpg 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-600x894.jpg 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/p>\n\n\n\n<p>Dimensionner correctement votre <a href=\"https:\/\/cnkuangya.com\/fr\/pv-combiner-box\/\">Bo\u00eete de raccordement PV<\/a> and its internal components is not just a best practice\u2014it&#8217;s a fundamental requirement for a safe, reliable, and code-compliant installation. An undersized component can lead to fire hazards, while an oversized one may fail to provide adequate protection.<\/p>\n\n\n\n<p>This guide will walk you through the essential steps for matching your combiner box&#8217;s voltage and current ratings to your specific solar array, with a focus on the requirements outlined in the National Electrical Code (NEC). We will cover:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Principes de s\u00e9curit\u00e9 fondamentaux de l'article 690 du NEC<\/li>\n\n\n\n<li>Calcul de la tension maximale du syst\u00e8me en fonction des conditions du site<\/li>\n\n\n\n<li>Dimensionnement des fusibles de la cha\u00eene de courant continu et de la protection principale contre les surintensit\u00e9s<\/li>\n\n\n\n<li><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"500\" class=\"wp-image-2280\" style=\"width: 750px;\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring.webp\" alt=\"\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring.webp 700w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-300x200.webp 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-18x12.webp 18w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-600x400.webp 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/cdn.gooo.ai\/web-images\/f98a9597b933747a0375ac33ca63d7b9aa7aa76297f229a1af932c02b15e0289\" alt=\"Sch\u00e9ma montrant les diff\u00e9rents composants \u00e0 l&#039;int\u00e9rieur d&#039;une bo\u00eete de raccordement PV, y compris l&#039;entr\u00e9e CC, les fusibles, les barres omnibus et le circuit de sortie.\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Les fondements : Comprendre l'article 690 du NEC<\/h3>\n\n\n\n<p>Pour toute installation photovolta\u00efque aux \u00c9tats-Unis, l'article 690 du NEC fait autorit\u00e9. Cette section du code est sp\u00e9cifiquement d\u00e9di\u00e9e aux syst\u00e8mes solaires photovolta\u00efques et traite des caract\u00e9ristiques uniques et des risques potentiels de la production d'\u00e9nergie en courant continu. Il fournit un cadre pour tout ce qui concerne le c\u00e2blage et la mise \u00e0 la terre, les moyens de d\u00e9connexion et la protection contre les surintensit\u00e9s. Le respect de l'article 690 est essentiel pour garantir que votre syst\u00e8me est s\u00fbr et qu'il passera l'inspection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Partie 1 : Adaptation de la tension du syst\u00e8me PV<\/h3>\n\n\n\n<p>Le premier param\u00e8tre \u00e0 d\u00e9terminer, et le plus important, est la tension maximale du syst\u00e8me. Tous les composants d'un circuit, des fils aux fusibles en passant par la bo\u00eete de raccordement elle-m\u00eame, doivent avoir une tension nominale \u00e9gale ou sup\u00e9rieure \u00e0 la tension maximale qu'ils sont susceptibles de subir.<\/p>\n\n\n\n<p>In a PV system, the maximum voltage is determined by the number of modules in a series string and their open-circuit voltage (Voc), found on the module&#8217;s datasheet. However, voltage is inversely proportional to temperature; a solar panel&#8217;s voltage is highest on the coldest possible day. NEC requires you to calculate the maximum voltage for the lowest expected ambient temperature at your site.<\/p>\n\n\n\n<p><strong>Comment calculer la tension maximale du syst\u00e8me :<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Trouver le Voc :<\/strong> Look up the Open-Circuit Voltage (Voc) on your solar module&#8217;s datasheet.<\/li>\n\n\n\n<li><strong>D\u00e9terminer la temp\u00e9rature la plus basse :<\/strong> Recherchez la temp\u00e9rature minimale record pour votre lieu de r\u00e9sidence. Vous pouvez souvent trouver cette information dans les donn\u00e9es m\u00e9t\u00e9orologiques locales ou dans les tableaux de temp\u00e9rature de conception de l'ASHRAE.<\/li>\n\n\n\n<li><strong>Trouver le facteur de correction de la temp\u00e9rature :<\/strong> La fiche technique du module fournit un coefficient de temp\u00e9rature pour Voc, exprim\u00e9 en pourcentage ou en V\/\u00b0C. Utilisez-le pour trouver le facteur de correction pour votre temp\u00e9rature la plus basse par rapport \u00e0 la temp\u00e9rature STC (Standard Test Condition) de 25\u00b0C. Le NEC fournit des tableaux dans l'article 690.7 pour un calcul simplifi\u00e9.<\/li>\n\n\n\n<li><strong>Calculer le Voc. corrig\u00e9<\/strong> <code>Voc corrig\u00e9 = Voc \u00d7 [1 + (Temp\u00e9rature la plus basse \u00b0C - 25\u00b0C) \u00d7 (Coefficient de temp\u00e9rature Voc %\/\u00b0C)].<\/code><\/li>\n\n\n\n<li><strong>Calculer la tension maximale du syst\u00e8me :<\/strong> <code>Tension maximale du syst\u00e8me = Voc corrig\u00e9 \u00d7 nombre de modules en s\u00e9rie<\/code><\/li>\n<\/ol>\n\n\n\n<p><strong>Exemple :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Voc du module : 48.5V<\/li>\n\n\n\n<li>Temp\u00e9rature minimale du site : -10\u00b0C<\/li>\n\n\n\n<li>Nombre de modules par cha\u00eene : 12<\/li>\n\n\n\n<li>Coefficient de temp\u00e9rature Voc : -0,28%\/\u00b0C<\/li>\n\n\n\n<li>Voc corrig\u00e9 = <code>48.5V \u00d7 [1 + (-10 - 25) \u00d7 (-0.0028)]<\/code> = <code>48.5V \u00d7 [1 + (-35 \u00d7 -0.0028)]<\/code> = <code>48.5V \u00d7 1.098<\/code> = 53.25V<\/li>\n\n\n\n<li><strong>Tension maximale du syst\u00e8me<\/strong> = <code>53.25V \u00d7 12<\/code> = <strong>639V<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Dans ce cas, le syst\u00e8me n\u00e9cessite une bo\u00eete de raccordement, des fusibles et des disjoncteurs d'au moins 639V. Par cons\u00e9quent, vous devez s\u00e9lectionner des composants d'une classe standard de 1000V DC, car des composants de 600V seraient insuffisants.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Partie 2 : <a href=\"https:\/\/cnkuangya.com\/fr\/pv-combiner-box\/\">Bo\u00eete combin\u00e9e PV<\/a> Dimensionnement et fusion des fils DC<\/h3>\n\n\n\n<p>Apr\u00e8s avoir d\u00e9termin\u00e9 la tension nominale, l'\u00e9tape suivante consiste \u00e0 dimensionner les dispositifs de protection contre les surintensit\u00e9s (OCPD), qui sont g\u00e9n\u00e9ralement des fusibles. L'objectif principal des fusibles de branche est de prot\u00e9ger contre le courant inverse. Une d\u00e9faillance dans une branche peut entra\u00eener une r\u00e9troalimentation des autres branches, ce qui cr\u00e9e une situation de surintensit\u00e9 dangereuse.<\/p>\n\n\n\n<p>Selon la norme NEC 690.9, la fusion au niveau de la corde est requise chaque fois que vous avez <strong>trois cordes ou plus en parall\u00e8le<\/strong>. With only two strings, the reverse current potential is not high enough to exceed the module&#8217;s fuse rating, so fuses are not required by code (though they are still sometimes used as a disconnecting means).<\/p>\n\n\n\n<p><strong>Comment dimensionner les fusibles pour cordes :<\/strong><\/p>\n\n\n\n<p>The NEC requires that the fuse be rated to handle continuous duty and potential irradiance spikes. This is accomplished by multiplying the module&#8217;s Short-Circuit Current (Isc) by a factor of 1.56.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>1,25 facteur<\/strong> pour une charge continue (circuits pouvant fonctionner pendant plus de 3 heures).<\/li>\n\n\n\n<li><strong>1,25 facteur<\/strong> for potential &#8220;irradiance enhancement&#8221; where sun exposure can exceed the standard 1000 W\/m\u00b2.<\/li>\n\n\n\n<li><code>1.25 \u00d7 1.25 = 1.56<\/code><\/li>\n<\/ul>\n\n\n\n<p><strong>Formule de calcul du calibre des fusibles :<\/strong> <code>Calibre minimal des fusibles \u2265 Isc du module \u00d7 1,56<\/code><\/p>\n\n\n\n<p>Apr\u00e8s avoir calcul\u00e9 ce minimum, vous s\u00e9lectionnez la taille de fusible standard sup\u00e9rieure.<\/p>\n\n\n\n<p><strong>Limitation cruciale : Calibre maximal des fusibles de s\u00e9rie<\/strong>\\<br>Every solar module has a &#8220;Maximum Series Fuse Rating&#8221; listed on its datasheet. This value is an absolute limit. <strong>La taille du fusible calcul\u00e9e ne doit pas d\u00e9passer cette valeur.<\/strong> Si c'est le cas, la conception de votre syst\u00e8me est d\u00e9fectueuse, ce qui signifie g\u00e9n\u00e9ralement que le module choisi ne peut pas \u00eatre utilis\u00e9 avec autant de cordes en parall\u00e8le.<\/p>\n\n\n\n<p><strong>Exemple :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Module Isc : 10.5A<\/li>\n\n\n\n<li>Fusible maximum de la s\u00e9rie de modules : 20A<\/li>\n\n\n\n<li>Calibre minimum des fusibles = <code>10.5A \u00d7 1.56<\/code> = <strong>16.38A<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Sur la base de ce calcul, vous choisirez la taille standard sup\u00e9rieure, c'est-\u00e0-dire un <strong>20A<\/strong> fuse. Since 20A is equal to the module&#8217;s maximum series fuse rating, this is a valid selection. If the calculation had resulted in 21A, you would not be able to use a 25A fuse, and the design would need to be re-evaluated.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/cdn.gooo.ai\/web-images\/357e85dc73b217fa84fb935d7868800fccfd950772178c1989038765798e398e\" alt=\"Bo\u00eete de raccordement solaire ouverte montrant le c\u00e2blage interne, les barres omnibus et les porte-fusibles.\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Partie 3 : Coordination des protections contre les surintensit\u00e9s<\/h3>\n\n\n\n<p>La coordination de la protection garantit qu'en cas de d\u00e9faut, le bon OCPD s'ouvre en premier. En cas de d\u00e9faut sur une seule branche, il faut que le fusible de la branche individuelle saute, isolant uniquement cette branche sans mettre l'ensemble du r\u00e9seau hors tension. L'OCPD principal \u00e0 la sortie de la bo\u00eete combin\u00e9e ne doit se d\u00e9clencher qu'en cas de d\u00e9faut majeur sur les conducteurs principaux menant \u00e0 l'onduleur.<\/p>\n\n\n\n<p>Pour ce faire, il faut s'assurer que l'appareil en aval a une puissance inf\u00e9rieure \u00e0 celle de l'appareil en amont.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Composant<\/strong><\/th><th><strong>Objectif<\/strong><\/th><th><strong>R\u00e8gle empirique de dimensionnement<\/strong><\/th><th><strong>R\u00e9f\u00e9rence NEC<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Fusible \u00e0 corde<\/strong><\/td><td>Prot\u00e8ge les cha\u00eenes individuelles contre les d\u00e9fauts de courant inverse provenant d'autres cha\u00eenes.<\/td><td><code>Isc \u00d7 1,56<\/code> (et doit \u00eatre \u2264 Fusible maximum du module)<\/td><td><code>690.9(A)<\/code><\/td><\/tr><tr><td><strong>Combinateur principal OCPD<\/strong><\/td><td>Prot\u00e8ge le fil de sortie principal entre la bo\u00eete de raccordement et l'onduleur.<\/td><td>Somme de tous les calibres de fusibles de la cha\u00eene, arrondie \u00e0 la taille du disjoncteur standard le plus proche. Ou <code>(Total Isc \u00d7 1,25)<\/code> et choisir la taille OCPD standard suivante.<\/td><td><code>690.9(A)<\/code> &amp; <code>240.4<\/code><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Foire aux questions (FAQ)<\/h3>\n\n\n\n<p><strong>Ai-je besoin de fusibles pour seulement deux cha\u00eenes parall\u00e8les ?<\/strong>\\<br>No. According to NEC 690.9, overcurrent protection is only required when there are three or more strings in parallel. With two strings, the maximum fault current that one string can source to the other is limited to the Isc of one string, which is below the module&#8217;s maximum fuse rating.<\/p>\n\n\n\n<p><strong>Puis-je utiliser des fusibles ou des disjoncteurs \u00e0 courant alternatif pour des circuits \u00e0 courant continu ?<\/strong>\\<br>Non, vous devez utiliser des composants sp\u00e9cifiquement con\u00e7us pour les circuits \u00e0 courant continu. Les arcs en courant continu sont beaucoup plus difficiles \u00e0 \u00e9teindre que les arcs en courant alternatif. Un dispositif homologu\u00e9 pour le courant alternatif ne parviendra probablement pas \u00e0 interrompre en toute s\u00e9curit\u00e9 un d\u00e9faut de courant continu, ce qui entra\u00eenera un risque important d'incendie et de s\u00e9curit\u00e9.<\/p>\n\n\n\n<p><strong>Que se passe-t-il si j'installe un fusible de la mauvaise taille ?<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Trop petit :<\/strong> The fuse will be subject to &#8220;nuisance tripping,&#8221; blowing under normal operating conditions (e.g., on a cool, very sunny day), causing unnecessary system downtime.<\/li>\n\n\n\n<li><strong>Trop grand :<\/strong> A fuse that is too large (especially one exceeding the module&#8217;s Maximum Series Fuse Rating) will not protect the module from damaging reverse currents. This can lead to module failure and creates a fire risk.<\/li>\n<\/ul>\n\n\n\n<p><strong>Pourquoi le multiplicateur de 1,56 est-il utilis\u00e9 pour le dimensionnement ?<\/strong>\\<br>It&#8217;s a combined safety factor required by the NEC. It consists of two separate 1.25 multipliers: one to account for the fact that solar circuits are considered &#8220;continuous loads&#8221; (running at max current for more than 3 hours), and a second to account for irradiance levels that can exceed standard test conditions, causing current to rise temporarily above the rated Isc. (1.25 x 1.25 = 1.56).<\/p>\n\n\n\n<p><strong>Qu'est-ce que le \u201ccalibre maximal des fusibles de s\u00e9rie\u201d d'un module ?<\/strong>\\<br>Il s'agit d'un indice de s\u00e9curit\u00e9 d\u00e9termin\u00e9 par le fabricant du module et certifi\u00e9 par UL. Il indique le courant maximal que le module peut supporter sans \u00eatre endommag\u00e9 lorsqu'il est soumis \u00e0 un courant inverse. Vous ne devez jamais installer un fusible ou un OCPD d'une valeur sup\u00e9rieure \u00e0 cette valeur.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"1024\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-687x1024.jpg\" alt=\"\" class=\"wp-image-2281\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-687x1024.jpg 687w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-201x300.jpg 201w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-768x1145.jpg 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-1030x1536.jpg 1030w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-1374x2048.jpg 1374w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-8x12.jpg 8w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-300x447.jpg 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-600x894.jpg 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-scaled.jpg 1717w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Conclusion<\/h3>\n\n\n\n<p>Matching a PV combiner box&#8217;s current and voltage ratings is a systematic process guided by engineering principles and the strict safety standards of the NEC. The core takeaways are:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>La tension d'abord :<\/strong> D\u00e9terminez toujours la tension maximale du syst\u00e8me en utilisant la temp\u00e9rature la plus basse pr\u00e9vue pour votre site. Tous les composants doivent \u00eatre pr\u00e9vus pour cette tension.<\/li>\n\n\n\n<li><strong>Second en cours :<\/strong> Size string fuses based on the module&#8217;s Isc and the 1.56x multiplier, but never exceed the module&#8217;s Maximum Series Fuse Rating.<\/li>\n\n\n\n<li><strong>Le code est la cl\u00e9 :<\/strong> When in doubt, defer to NEC Article 690 and the manufacturer&#8217;s datasheets for all components.<\/li>\n<\/ol>\n\n\n\n<p>By following these guidelines, you can ensure your solar array&#8217;s combiner box is sized safely, reliably, and professionally, forming a robust foundation for your entire PV system.<\/p>","protected":false},"excerpt":{"rendered":"<p>In a solar photovoltaic (PV) system, the combiner box plays a central role in consolidating power and ensuring safety. It&#8217;s a junction box where the output of multiple solar strings are connected in parallel, combining their current before sending it to the inverter. More importantly, it houses the critical overcurrent protection devices (fuses or circuit [&hellip;]<\/p>","protected":false},"author":4,"featured_media":2285,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[35],"tags":[],"class_list":["post-2279","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/2279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=2279"}],"version-history":[{"count":1,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/2279\/revisions"}],"predecessor-version":[{"id":2283,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/2279\/revisions\/2283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/2285"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=2279"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/categories?post=2279"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/tags?post=2279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}