{"id":1730,"date":"2025-09-19T12:43:49","date_gmt":"2025-09-19T12:43:49","guid":{"rendered":"https:\/\/cnkuangya.com\/?p=1730"},"modified":"2026-04-24T16:16:45","modified_gmt":"2026-04-24T08:16:45","slug":"comment-choisir-un-dispositif-de-protection-contre-les-surtensions","status":"publish","type":"post","link":"https:\/\/cnkuangya.com\/fr\/blog\/how-to-select-surge-protective-device\/","title":{"rendered":"Comment choisir le bon dispositif de protection contre les surtensions (SPD) pour les applications industrielles et renouvelables ?"},"content":{"rendered":"<section style=\"margin:18px 0 28px;\">\n  <div style=\"border:1px solid #e5e7eb;border-radius:12px;padding:16px;background:#ffffff;\">\n    <p style=\"margin:0 0 6px;font-size:12px;line-height:1.6;color:#6b7280;\">\n      Mise \u00e0 jour : <time datetime=\"2025-09-19\" style=\"color:#6b7280;\">19 septembre 2025<\/time> - Temps de lecture : ~18-22 min\n    <\/p>\n    <p style=\"margin:0;color:#0f172a;line-height:1.85;font-size:18px;\">\n      S\u00e9lection de la bonne <strong>Dispositif de protection contre les surtensions (SPD)<\/strong> est l'une des d\u00e9cisions \u00e0 plus fort ROI dans les domaines de la distribution BT, du PV\/ESS, de la recharge des VE et de l'automatisation industrielle.\n      Ce guide compile <em>ax\u00e9 sur les normes<\/em> les crit\u00e8res (IEC\/UL\/NEC), les r\u00e8gles de placement et les conseils de nomenclature pour les deux cat\u00e9gories de produits. <strong>AC<\/strong> et <strong>DC<\/strong> et les syst\u00e8mes de gestion des d\u00e9chets.\n      Voir les <a href=\"#table-a\" style=\"color:#e11d48;text-decoration:none;\">tableaux de r\u00e9f\u00e9rence<\/a> et <a href=\"#sources\" style=\"color:#e11d48;text-decoration:none;\">sources<\/a> \u00e0 la fin.\n    <\/p>\n    <div style=\"display:flex;flex-wrap:wrap;gap:10px;margin-top:10px;\">\n      <a href=\"\/fr\/ac-spd\/\" style=\"display:inline-block;padding:10px 14px;border-radius:999px;border:1px solid #111827;color:#ffffff;background:#111827;text-decoration:none;font-size:14px;line-height:1;\">AC SPD - S\u00e9lecteur et guide<\/a>\n      <a href=\"\/fr\/dc-spd\/\" style=\"display:inline-block;padding:10px 14px;border-radius:999px;border:1px solid #111827;color:#111827;background:#ffffff;text-decoration:none;font-size:14px;line-height:1;\">DC SPD - PV\/ESS<\/a>\n      <a href=\"\/fr\/pv-combiner-box\/\" style=\"display:inline-block;padding:10px 14px;border-radius:999px;border:1px solid #111827;color:#111827;background:#ffffff;text-decoration:none;font-size:14px;line-height:1;\">Bo\u00eete combin\u00e9e PV<\/a>\n      <a href=\"\/fr\/dc-fuse\/\" style=\"display:inline-block;padding:10px 14px;border-radius:999px;border:1px solid #111827;color:#111827;background:#ffffff;text-decoration:none;font-size:14px;line-height:1;\">Fusible DC (gPV)<\/a>\n      <a href=\"\/fr\/contact-us\/\" style=\"display:inline-block;padding:10px 14px;border-radius:999px;border:1px solid #111827;color:#111827;background:#ffffff;text-decoration:none;font-size:14px;line-height:1;\">Contacter Kuangya<\/a>\n    <\/div>\n  <\/div>\n<\/section>\n\n\n\n<section style=\"margin:24px 0 28px;\">\n  <!-- \u6587\u5b57 -->\n  <h2 style=\"font-size:22px;line-height:1.3;margin:0 0 10px;color:#111827;\">1) Pourquoi l'investissement dans le DOCUP est rentable<\/h2>\n  <p style=\"margin:0 0 10px;color:#111827;line-height:1.85;font-size:16px;\">\n    Les temps d'arr\u00eat non planifi\u00e9s co\u00fbtent souvent <strong>1-5M USD\/heure<\/strong>les cas graves approchent <strong>USD 300k\/min<\/strong>.\n    Les surtensions dues \u00e0 la foudre ou aux interrupteurs sont <em>pr\u00e9visible et r\u00e9alisable<\/em>; les SPD coordonn\u00e9s bloquent les impulsions \u00e0 haute \u00e9nergie et prot\u00e8gent les PLC\/VFD\/IT.\n  <\/p>\n\n  <!-- \u4fe1\u606f\u5361 -->\n  <div style=\"border:1px solid #e5e7eb;border-radius:12px;background:#f9fafb;padding:12px 14px;margin:10px 0;\">\n    <p style=\"margin:0;color:#374151;line-height:1.75;font-size:15px;\">\n      Les r\u00e9seaux de d\u00e9tection am\u00e9ricains enregistrent des dizaines, voire des centaines de millions d'\u00e9v\u00e9nements de foudre par an ; la Floride est souvent en t\u00eate pour la densit\u00e9, le Texas pour les totaux.\n      Utilisez des sp\u00e9cifications tenant compte de la g\u00e9ographie (voir \u00a78) pour justifier des taux de foudre plus \u00e9lev\u00e9s. <strong>Iimp\/In<\/strong> des notations.\n    <\/p>\n  <\/div>\n\n  <!-- \u9884\u7559\u56fe\u7247\u4f4d\uff0816:9\uff09 -->\n  <figure style=\"margin:12px 0 0;border:1px solid #e5e7eb;border-radius:12px;overflow:hidden;background:#fafafa;\">\n    <div style=\"width:100%;aspect-ratio:16\/9;display:block;background:#e5e7eb;\">\n      <img decoding=\"async\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/banner6.webp\"\n           alt=\"Contexte de la foudre (CC BY-SA)\" style=\"width:100%;height:100%;object-fit:cover;display:block;\">\n    <\/div>\n    <figcaption style=\"font-size:12px;color:#6b7280;padding:8px 10px;border-top:1px solid #e5e7eb;background:#fff;\">\n      <\/figcaption>\n  <\/figure>\n<\/section>\n\n\n\n<section style=\"margin:24px 0 28px;\">\n  <h2 style=\"font-size:22px;line-height:1.3;margin:0 0 8px;color:#111827;\">2) Paysage des normes (IEC \/ UL \/ NEC)<\/h2>\n  <p style=\"margin:0 0 12px;color:#111827;line-height:1.85;font-size:16px;\">\n    La norme IEC 61643 d\u00e9finit les performances et les formes d'onde ; la norme UL 1449 \u00e9num\u00e8re les normes de s\u00e9curit\u00e9 et de conformit\u00e9 pour l'Am\u00e9rique du Nord ; l'article 242 de la norme NEC 2023 impose l'utilisation dans plusieurs contextes.\n  <\/p>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:12px;\">\n    <div style=\"border:1px solid #e5e7eb;border-radius:12px;background:#ffffff;padding:14px;\">\n      <h3 style=\"font-size:18px;margin:0 0 6px;color:#111827;\">IEC 61643<\/h3>\n      <p style=\"margin:0;color:#111827;line-height:1.7;font-size:15px;\">\n        Type 1 : <strong>10\/350 \u03bcs<\/strong> (<em>Iimp<\/em>) - Type 2 : <strong>8\/20 \u03bcs<\/strong> (<em>In\/Imax<\/em>) - Type 3 : Combinaison (<em>Uoc<\/em>).\n        PV\/DC : <strong>IEC 61643-31<\/strong> \u22641500 VDC.\n      <\/p>\n      <p style=\"margin:8px 0 0;font-size:14px;line-height:1.6;\">\n        <a href=\"https:\/\/webstore.iec.ch\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Boutique en ligne de la CEI<\/a>\n      <\/p>\n    <\/div>\n    <div style=\"border:1px solid #e5e7eb;border-radius:12px;background:#ffffff;padding:14px;\">\n      <h3 style=\"font-size:18px;margin:0 0 6px;color:#111827;\">UL 1449<\/h3>\n      <p style=\"margin:0;color:#111827;line-height:1.7;font-size:15px;\">Liste UL pour les SPD \u00e0 connexion permanente ; 4e \u00e9dition (2016) marquages affin\u00e9s.<\/p>\n      <p style=\"margin:8px 0 0;font-size:14px;line-height:1.6;\">\n        <a href=\"https:\/\/www.intertek.com\/standards-updates\/ul1449-4th-edition\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Intertek<\/a> -\n        <a href=\"https:\/\/www.se.com\/us\/en\/download\/document\/UL1449_4thEd_Overview\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Schneider PDF<\/a>\n      <\/p>\n    <\/div>\n    <div style=\"border:1px solid #e5e7eb;border-radius:12px;background:#ffffff;padding:14px;\">\n      <h3 style=\"font-size:18px;margin:0 0 6px;color:#111827;\">NEC 2023<\/h3>\n      <p style=\"margin:0;color:#111827;line-height:1.7;font-size:15px;\">Article <strong>242<\/strong> r\u00e9git la protection contre les surtensions. Respecter les r\u00e8gles d'inscription et de placement.<\/p>\n      <p style=\"margin:8px 0 0;font-size:14px;line-height:1.6;\">\n        <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">NFPA 70<\/a>\n      <\/p>\n    <\/div>\n  <\/div>\n<\/section>\n\n\n\n<section style=\"margin:24px 0 28px;\">\n  <h2 style=\"font-size:22px;line-height:1.3;margin:0 0 8px;color:#111827;\">3) D\u00e9codage du \"type\" de SPD par rapport aux formes d'onde de test<\/h2>\n  <p style=\"margin:0 0 12px;color:#111827;line-height:1.85;font-size:16px;\">\n    Choisir le type en fonction de l'exposition et de la hi\u00e9rarchie des cartes ; coordonner la tension r\u00e9siduelle (<em>Haut de la page<\/em>) \u00e0 tous les stades.\n  <\/p>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:12px;margin-bottom:12px;\">\n    <div style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;background:#f9fafb;\">\n      <h3 style=\"font-size:18px;margin:0 0 6px;color:#B5220E;\">Type 1 (classe I)<\/h3>\n      <p style=\"margin:0;color:#111827;line-height:1.7;font-size:15px;\">Test : <strong>10\/350 \u03bcs<\/strong> (<em>Iimp<\/em>). Installer \u00e0 <strong>entr\u00e9e de service<\/strong> en cas de LPS\/frais g\u00e9n\u00e9raux.<\/p>\n    <\/div>\n    <div style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;background:#f9fafb;\">\n      <h3 style=\"font-size:18px;margin:0 0 6px;color:#B5220E;\">Type 2 (classe II)<\/h3>\n      <p style=\"margin:0;color:#111827;line-height:1.7;font-size:15px;\">Test : <strong>8\/20 \u03bcs<\/strong> (<em>In\/Imax<\/em>). Protection de l'\u00e9pine dorsale des cartes auxiliaires.<\/p>\n    <\/div>\n    <div style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;background:#f9fafb;\">\n      <h3 style=\"font-size:18px;margin:0 0 6px;color:#B5220E;\">Type 3 (Classe III)<\/h3>\n      <p style=\"margin:0;color:#111827;line-height:1.7;font-size:15px;\">Test : <strong>Combinaison<\/strong> (<em>Uoc<\/em>). Proximit\u00e9 de charges sensibles (PLC, VFD, IT).<\/p>\n    <\/div>\n  <\/div>\n  <!-- \u9884\u7559\u5c0f\u56fe -->\n  <figure style=\"margin:0;border:1px solid #e5e7eb;border-radius:12px;overflow:hidden;background:#fafafa;\">\n    <div style=\"width:100%;aspect-ratio:4\/3;background:#e5e7eb;\">\n      <img decoding=\"async\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KYPV-1500-3p-2.jpg\"\n           alt=\"Photo SPD (CC BY-SA)\" style=\"width:100%;height:100%;object-fit:cover;display:block;\">\n    <\/div>\n    <figcaption style=\"font-size:12px;color:#6b7280;padding:8px 10px;border-top:1px solid #e5e7eb;background:#fff;\">\n      \n    <\/figcaption>\n  <\/figure>\n  <p style=\"margin:10px 0 0;color:#374151;line-height:1.7;font-size:14px;\">Hybride <strong>Type 1+2<\/strong> = haute \u00e9nergie + faible r\u00e9sidu. S\u00e9lecteurs :\n    <a href=\"\/fr\/ac-spd\/#selector\" style=\"color:#0ea5e9;text-decoration:none;\">AC<\/a> -\n    <a href=\"\/fr\/dc-spd\/#sec2\" style=\"color:#0ea5e9;text-decoration:none;\">DC<\/a>\n  <\/p>\n<\/section>\n\n\n\n<section id=\"acdc\" class=\"ky-section\">\n  <h2>4) CA contre CC (PV\/ESS) - m\u00eame physique, contraintes diff\u00e9rentes<\/h2>\n  <p>\n    <strong>C\u00f4t\u00e9 AC<\/strong> (IEC 61643-11 \/ UL 1449) : choisir le type 1\/2\/3 en fonction de l'exposition et de la hi\u00e9rarchie des cartes, puis de la taille. <em>Uc<\/em>, <em>In\/Imax<\/em>, <em>Haut de la page<\/em>.\n    <strong>C\u00f4t\u00e9 DC<\/strong> (IEC 61643-31) : R\u00e9seaux photovolta\u00efques jusqu'\u00e0 <strong>1500 VDC<\/strong> avec des comportements diff\u00e9rents en termes de temp\u00e9rature, de polarit\u00e9 et de courant inverse par rapport aux dispositifs \u00e0 courant alternatif.\n  <\/p>\n  <p>\n    Dans le BOS moderne, <a href=\"\/fr\/pv-combiner-box\/\">Bo\u00eetes de raccordement PV<\/a> int\u00e8grent souvent <strong>Type 2 DC SPD<\/strong>Les fusibles gPV et les d\u00e9connexions DC r\u00e9duisent le nombre de bo\u00eetiers et simplifient le travail sur le terrain.\n  <\/p>\n  <figure>\n    <img decoding=\"async\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/PV-combiner-box-banner-.webp\" alt=\"Champ photovolta\u00efque \" \/>\n    <figcaption>Image : Champ photovolta\u00efque (Wikimedia Commons, CC BY-SA). Envisager des disjoncteurs aux entr\u00e9es CC des combinateurs et des onduleurs conform\u00e9ment \u00e0 la norme CEI 61643-31.<\/figcaption>\n  <\/figure>\n<\/section>\n\n\n\n<section id=\"layers\" class=\"ky-section\">\n  <h2>5) La \"recette\" de la protection multicouche<\/h2>\n  <ol>\n    <li><strong>Entr\u00e9e de service \/ MSB :<\/strong> <strong>Type 1<\/strong> (ou <strong>1+2<\/strong>) avec un nombre suffisant de <em>Iimp<\/em>; chemin terrestre le plus court et le plus rectiligne.<\/li>\n    <li><strong>Tableaux de sous-distribution :<\/strong> <strong>Type 2<\/strong> dimensionn\u00e9s en fonction du niveau de d\u00e9faut de la branche et de la longueur des c\u00e2bles ; coordonner <em>Haut de la page<\/em> avec l'\u00e9tage MSB.<\/li>\n    <li><strong>Crit\u00e8res d'\u00e9valuation sensibles :<\/strong> <strong>Type 3<\/strong> \u00e0 proximit\u00e9 des entr\u00e9es d'appareils (PLC, VFD, serveurs).<\/li>\n  <\/ol>\n  <p>Cette cascade refl\u00e8te les principes de s\u00e9lection et de montage de la norme CEI 60364-5-53 et les directives courantes des fabricants.<\/p>\n<\/section>\n\n\n\n<section style=\"margin:24px 0 28px;\">\n  <h2 style=\"font-size:22px;line-height:1.3;margin:0 0 8px;color:#111827;\">6) Liste de contr\u00f4le des tailles en neuf points<\/h2>\n  <div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(280px,1fr));gap:16px;align-items:start;\">\n    <ul style=\"margin:0; padding-left:18px; color:#111827; line-height:1.9; font-size:16px; list-style:disc;background:#ffffff;border:1px solid #e5e7eb;border-radius:12px;padding:14px;\">\n      <li><strong>Codes\/Listes :<\/strong> UL 1449 (U.S.), NEC 242.<\/li>\n      <li><strong>Type :<\/strong> 1 \/ 1+2 \/ 2 \/ 3 par niveau d'exposition et de conseil.<\/li>\n      <li><strong>Uc (MCOV) :<\/strong> &gt; tension continue la plus d\u00e9favorable.<\/li>\n      <li><strong>Iimp \/ In \/ Imax :<\/strong> faire correspondre la densit\u00e9 de la foudre et les points d'entr\u00e9e.<\/li>\n      <li><strong>En haut :<\/strong> la coordination \u00e9tape par \u00e9tape.<\/li>\n      <li><strong>P\u00f4le et mise \u00e0 la terre :<\/strong> Besoins TN\/TT\/IT et N-PE.<\/li>\n      <li><strong>SCCR \/ Backup OCPD :<\/strong> faire correspondre les tableaux des d\u00e9fauts actuels et des fournisseurs.<\/li>\n      <li><strong>L'environnement :<\/strong> Altitude, IP\/NEMA, longueur du c\u00e2ble.<\/li>\n      <li><strong>Entretien :<\/strong> Modules rempla\u00e7ables, fen\u00eatre d'\u00e9tat, alarme \u00e0 distance.<\/li>\n    <\/ul>\n    <!-- \u9884\u7559\u56fe\u7247\u4f4d -->\n    <figure style=\"margin:0;border:1px solid #e5e7eb;border-radius:12px;overflow:hidden;background:#fafafa;\">\n      <div style=\"width:100%;aspect-ratio:1\/1;background:#e5e7eb;\">\n        <img decoding=\"async\" src=\"https:\/\/images.pexels.com\/photos\/4254168\/pexels-photo-4254168.jpeg?auto=compress&#038;cs=tinysrgb&#038;w=1200\"\n             alt=\"Emplacement pour le c\u00e2blage du panneau\" style=\"width:100%;height:100%;object-fit:cover;display:block;\">\n      <\/div>\n      <figcaption style=\"font-size:12px;color:#6b7280;padding:8px 10px;border-top:1px solid #e5e7eb;background:#fff;\">\n        Remplacer par la photo de votre projet (c\u00e2blage du combinateur\/MSB).\n      <\/figcaption>\n    <\/figure>\n  <\/div>\n<\/section>\n\n\n\n<section style=\"margin:36px 0 28px;\">\n  <h2 style=\"font-size:28px;line-height:1.25;margin:0 0 10px;color:#111827;\">7) O\u00f9 installer les SPD dans les projets PV, ESS et VE ?<\/h2>\n  <ul style=\"margin:0 0 10px 18px;color:#111827;line-height:1.8;\">\n    <li><strong>Panneaux photovolta\u00efques :<\/strong> Au <em>bo\u00eetes combin\u00e9es<\/em> et <em>entr\u00e9es CC de l'onduleur<\/em>les longues courses ou les terrains expos\u00e9s peuvent n\u00e9cessiter les deux.<\/li>\n    <li><strong>ESS :<\/strong> Bus DC pr\u00e8s de l'interface batterie\/DC-DC, et c\u00f4t\u00e9 AC au PCS.<\/li>\n    <li><strong>Chargement des VE :<\/strong> Type 1 ou 1+2 au niveau du branchement (si LPS \/ a\u00e9rien), Type 2 au niveau de la distribution, Type 3 \u00e0 proximit\u00e9 des terminaux.<\/li>\n  <\/ul>\n  <p style=\"margin:0;color:#374151;line-height:1.8;\">\n    Voir aussi <a href=\"\/fr\/pv-combiner-box\/\" style=\"color:#0ea5e9;text-decoration:none;\">Bo\u00eetes combin\u00e9es PV<\/a> - <a href=\"\/fr\/dc-fuse\/\" style=\"color:#0ea5e9;text-decoration:none;\">Fusibles gPV haute tension<\/a>\n  <\/p>\n<\/section>\n\n\n\n<section style=\"margin:36px 0 28px;\">\n  <h2 style=\"font-size:28px;line-height:1.25;margin:0 0 10px;color:#111827;\">8) Data snapshot: lightning exposure &#038; why it changes your BOM<\/h2>\n  <p style=\"margin:0 0 10px;color:#111827;line-height:1.8;\">\n    L'exposition \u00e0 la foudre n'est pas uniforme. Les rapports am\u00e9ricains sur la foudre citent r\u00e9guli\u00e8rement <strong>90-240+ millions<\/strong> par an (dans le nuage + CG) en fonction de la m\u00e9thodologie.\n    Le Texas est souvent en t\u00eate pour le nombre total d'\u00e9v\u00e9nements, tandis que la Floride est souvent en t\u00eate pour la densit\u00e9. Pour les parcs \u00e9oliens et les infrastructures de grande hauteur, le nombre de coups par site peut d\u00e9passer les milliers.\n  <\/p>\n  <p style=\"margin:0 0 8px;color:#111827;line-height:1.8;\">\n    Pour l'\u00e9tablissement du budget, utilisez les cartes au niveau du comt\u00e9 de NOAA\/NCEI ou les rapports annuels de Vaisala\/AEM pour justifier les \u00e9l\u00e9ments suivants <em>Iimp\/In<\/em> les choix et l'emplacement des sites.\n  <\/p>\n  <ul style=\"margin:0 0 0 18px;color:#111827;line-height:1.8;\">\n    <li><a href=\"https:\/\/www.ncei.noaa.gov\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Climatologie de la foudre NOAA\/NCEI<\/a><\/li>\n    <li><a href=\"https:\/\/www.vaisala.com\/en\/lightning\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Rapports sur la foudre de Vaisala<\/a><\/li>\n    <li><a href=\"https:\/\/www.aem.eco\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">R\u00e9seaux m\u00e9t\u00e9orologiques AEM<\/a><\/li>\n  <\/ul>\n<\/section>\n\n\n\n<section id=\"table-a\" style=\"margin:24px 0 28px;\">\n  <h2 style=\"font-size:22px;line-height:1.3;margin:0 0 8px;color:#111827;\">9) Tableaux de r\u00e9f\u00e9rence rapide<\/h2>\n  <p style=\"margin:0 0 10px;color:#111827;line-height:1.85;font-size:16px;\">Copiez ces lignes dans vos fiches techniques comme point de d\u00e9part.<\/p>\n  <div style=\"overflow:auto;border:1px solid #e5e7eb;border-radius:12px;\">\n    <table style=\"border-collapse:collapse;width:100%;font-size:15px;\">\n      <thead>\n        <tr>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Type de DOCUP<\/th>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Test primaire<\/th>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Principales notations<\/th>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Emplacement typique<\/th>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Notes<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>Type 1<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">10\/350 \u03bcs (<em>Iimp<\/em>)<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Uc, <strong>Iimp<\/strong>, Up<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Entr\u00e9e de service \/ MSB<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Courant de foudre direct partiel<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>Type 2<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">8\/20 \u03bcs (<em>In\/Imax<\/em>)<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Uc, <strong>In\/Imax<\/strong>, Up<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Tableaux de sous-distribution<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Protection de l'\u00e9pine dorsale<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;\"><strong>Type 3<\/strong><\/td>\n          <td style=\"padding:10px;\">Combinaison (<em>Uoc<\/em>)<\/td>\n          <td style=\"padding:10px;\">Uc, Uoc, Up<\/td>\n          <td style=\"padding:10px;\">A proximit\u00e9 de charges sensibles<\/td>\n          <td style=\"padding:10px;\">Clampage final, coordonn\u00e9 avec le type 2<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <!-- \u5c0f\u56fe\u5360\u4f4d -->\n  <div style=\"margin-top:8px;border:1px dashed #e5e7eb;border-radius:10px;padding:8px;text-align:center;font-size:12px;color:#6b7280;\">\n    Image optionnelle : diagramme de formes d'ondes de test \/ gamme de produits\n  <\/div>\n<\/section>\n\n\n\n<section style=\"margin:24px 0 28px;\">\n  <h3 style=\"font-size:20px;margin:0 0 8px;color:#111827;\">Tableau B - Donn\u00e9es minimales \u00e0 sp\u00e9cifier dans chaque DOCUP<\/h3>\n  <div style=\"overflow:auto;border:1px solid #e5e7eb;border-radius:8px;\">\n    <table style=\"border-collapse:collapse;width:100%;font-size:15px;\">\n      <thead>\n        <tr>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Param\u00e8tres<\/th>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Pourquoi c'est important<\/th>\n          <th style=\"text-align:left;padding:10px;background:#f8fafc;border-bottom:1px solid #e5e7eb;\">Pi\u00e8ges typiques<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>Uc (MCOV)<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Doit d\u00e9passer la tension continue la plus d\u00e9favorable du syst\u00e8me<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Choix trop proche de la valeur nominale \u2192 stress thermique et fin de vie pr\u00e9coce<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>Iimp \/ In \/ Imax<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Correspondre \u00e0 l'environnement de surtension pr\u00e9vu<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Sous-dimensionnement au niveau du branchement ; utilisation abusive du type 2 l\u00e0 o\u00f9 le type 1 est n\u00e9cessaire<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>Haut de la page<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">D\u00e9termination des contraintes r\u00e9siduelles sur l'isolation\/\u00e9lectronique<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Absence de coordination entre les \u00e9tapes \u2192 protection de niveau \u00e9gal<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>SCCR \/ Backup OCPD<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">S\u00e9curit\u00e9 et s\u00e9lectivit\u00e9<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Inad\u00e9quation avec le courant de d\u00e9faut disponible ; ignorance des tables de dispositifs de secours du fournisseur<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\"><strong>Nombre de p\u00f4les et mise \u00e0 la terre<\/strong><\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">Les TN\/TT\/IT modifient l'ensemble des modules et les besoins des N-PE<\/td>\n          <td style=\"padding:10px;border-bottom:1px solid #f1f5f9;\">N-PE manquant sur TT ; PEN mal connect\u00e9 sur TN-C<\/td>\n        <\/tr>\n        <tr>\n          <td style=\"padding:10px;\"><strong>Environnement et montage<\/strong><\/td>\n          <td style=\"padding:10px;\">Temp\u00e9rature, altitude, IP\/NEMA ; acheminement des conducteurs<\/td>\n          <td style=\"padding:10px;\">Grandes longueurs de fils ; les courbes aigu\u00ebs augmentent l'inductance (augmentent le niveau de la borne).<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n<\/section>\n\n\n\n<section style=\"margin:36px 0 28px;\">\n  <h2 style=\"font-size:28px;line-height:1.25;margin:0 0 10px;color:#111827;\">10) R\u00e8gles relatives \u00e0 la mise \u00e0 la terre, au c\u00e2blage et \u00e0 la longueur des c\u00e2bles<\/h2>\n  <ul style=\"margin:0 0 10px 18px;color:#111827;line-height:1.8;\">\n    <li>Conserver les conducteurs SPD-terre et SPD-bus <strong>court, droit, adjacent<\/strong>.<\/li>\n    <li>\u00c9vitez les boucles ou les jolis habillages de c\u00e2bles qui augmentent l'inductance au moment de la surtension.<\/li>\n    <li>Utiliser les sp\u00e9cifications de couple du fournisseur ; les terminaisons l\u00e2ches s'\u00e9chauffent sous l'effet de surtensions r\u00e9p\u00e9t\u00e9es.<\/li>\n    <li>Sur les syst\u00e8mes TT, veillez \u00e0 ce que les modules N-PE et la liaison soient corrects afin que les courants reviennent par le chemin pr\u00e9vu.<\/li>\n  <\/ul>\n  <p style=\"margin:0;color:#374151;line-height:1.8;\">R\u00e9f\u00e9rence aux r\u00e8gles d'\u00e9rection globales : <a href=\"https:\/\/webstore.iec.ch\/publication\/60458\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">IEC 60364-5-53<\/a>.<\/p>\n<\/section>\n\n\n\n<section style=\"margin:36px 0 28px;\">\n  <h2 style=\"font-size:28px;line-height:1.25;margin:0 0 10px;color:#111827;\">11) Placements d\u00e9clench\u00e9s par le NEC (\u00c9tats-Unis)<\/h2>\n  <p style=\"margin:0 0 10px;color:#111827;line-height:1.8;\">\n    Le <strong>2023 NEC<\/strong> (NFPA 70) renforce l'utilisation des DPS dans plusieurs contextes (par exemple, protection de l'ensemble de la maison dans les habitations, contr\u00f4leurs de pompes \u00e0 incendie).\n    Article <strong>242<\/strong> couvre la protection contre les surtensions pour les installations de \u22641000 V ; il faut toujours faire correspondre la protection contre les surtensions \u00e0 celle de la protection contre les surtensions. <strong>UL 1449<\/strong> l'inscription et <strong>lieu d'installation<\/strong>.\n  <\/p>\n  <p style=\"margin:0;color:#374151;line-height:1.8;\">\n    R\u00e9f\u00e9rence : <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">NFPA 70 (NEC)<\/a> -\n    <a href=\"https:\/\/www.intertek.com\/standards-updates\/ul1449-4th-edition\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Explication de la norme UL 1449<\/a>\n  <\/p>\n<\/section>\n\n\n\n<section style=\"margin:36px 0 28px;\">\n  <h2 style=\"font-size:28px;line-height:1.25;margin:0 0 10px;color:#111827;\">12) Exemples concrets - choisir rapidement les notes<\/h2>\n\n  <h3 style=\"font-size:20px;margin:0 0 6px;color:#111827;\">A. Installation industrielle, service a\u00e9rien, pas de LPS, 400\/230 VAC TN-S<\/h3>\n  <ul style=\"margin:0 10px 12px 18px;color:#111827;line-height:1.8;\">\n    <li><strong>MSB :<\/strong> <em>Type 1<\/em> (ou <em>1+2<\/em>) avec <em>Iimp<\/em> \u2248 12,5-25 kA\/p\u00f4le typique ; <em>Uc<\/em> \u2265 275 VAC (L-N) pour les syst\u00e8mes de 230 V ; <em>Haut de la page<\/em> \u2264 1,5 kV.<\/li>\n    <li><strong>Sous-BD :<\/strong> <em>Type 2<\/em> \u00e0 <em>En<\/em> 20-40 kA, <em>Imax<\/em> 40 \u00e0 80 kA par risque de carte.<\/li>\n    <li><strong>Crit\u00e8res d'\u00e9valuation :<\/strong> <em>Type 3<\/em> aux charges VFD\/PLC\/IT.<\/li>\n  <\/ul>\n\n  <h3 style=\"font-size:20px;margin:0 0 6px;color:#111827;\">B. R\u00e9seau PV 1000 VDC (longues cha\u00eenes, montage au sol)<\/h3>\n  <ul style=\"margin:0 10px 12px 18px;color:#111827;line-height:1.8;\">\n    <li><strong>Bo\u00eete \u00e0 combinaisons :<\/strong> <em>Type 2 DC SPD<\/em> \u00e0 la norme IEC 61643-31 ; <em>Uc<\/em> \u2265 Vstring(max at Tmin) ; coordonn\u00e9es <em>Haut de la page<\/em> avec onduleur.<\/li>\n    <li><strong>Entr\u00e9e DC de l'onduleur :<\/strong> Ajoutez un deuxi\u00e8me \u00e9tage DC si les distances entre les c\u00e2bles sont importantes ou si le terrain est tr\u00e8s expos\u00e9.<\/li>\n  <\/ul>\n\n  <h3 style=\"font-size:20px;margin:0 0 6px;color:#111827;\">C. Plaque de recharge pour VE (commerciale)<\/h3>\n  <ul style=\"margin:0 10px 0 18px;color:#111827;line-height:1.8;\">\n    <li><strong>Service :<\/strong> <em>Type 1 ou 1+2<\/em> o\u00f9 il y a des LPS et des frais g\u00e9n\u00e9raux.<\/li>\n    <li><strong>Distribution :<\/strong> <em>Type 2<\/em> l'alimentation des groupes de chargeurs ; <em>Type 3<\/em> pr\u00e8s des entr\u00e9es du chargeur (si elles sont prises en charge).<\/li>\n  <\/ul>\n<\/section>\n\n\n\n<section style=\"margin:36px 0 28px;\">\n  <h2 style=\"font-size:28px;line-height:1.25;margin:0 0 10px;color:#111827;\">13) FAQ (r\u00e9ponses de niveau ing\u00e9nieur)<\/h2>\n\n  <details style=\"border:1px solid #e5e7eb;border-radius:8px;padding:10px 12px;margin:10px 0;background:#fff;\">\n    <summary style=\"cursor:pointer;font-weight:600;color:#111827;\">Ai-je toujours besoin du type 1 \u00e0 l'entr\u00e9e du service ?<\/summary>\n    <p style=\"margin:8px 0 0;color:#111827;line-height:1.8;\">Si vous disposez d'une source lumineuse ext\u00e9rieure ou d'un branchement a\u00e9rien, le type 1 (ou 1+2) est l'approche standard pour g\u00e9rer un courant de foudre direct partiel. Les b\u00e2timents aliment\u00e9s par le sous-sol justifient parfois une installation robuste de type 2, mais il faut \u00e9valuer le risque (densit\u00e9 de foudre, voies d'entr\u00e9e) et le code local.<\/p>\n  <\/details>\n\n  <details style=\"border:1px solid #e5e7eb;border-radius:8px;padding:10px 12px;margin:10px 0;background:#fff;\">\n    <summary style=\"cursor:pointer;font-weight:600;color:#111827;\">En quoi les d\u00e9nominations UL et IEC diff\u00e8rent-elles ?<\/summary>\n    <p style=\"margin:8px 0 0;color:#111827;line-height:1.8;\">La norme UL 1449 est une norme d'inscription et de s\u00e9curit\u00e9 ; la norme CEI 61643 d\u00e9finit les essais de performance et les types. De nombreuses fiches techniques affichent les deux. La 4e \u00e9dition de la norme UL 1449 (2016) a normalis\u00e9 des marquages et des exigences plus r\u00e9cents.<\/p>\n  <\/details>\n\n  <details style=\"border:1px solid #e5e7eb;border-radius:8px;padding:10px 12px;margin:10px 0;background:#fff;\">\n    <summary style=\"cursor:pointer;font-weight:600;color:#111827;\">Quels sont les chiffres \u00e0 optimiser ?<\/summary>\n    <p style=\"margin:8px 0 0;color:#111827;line-height:1.8;\">Dans l'ordre : <strong>Uc<\/strong> (droite, pas basse) \u2192 <strong>Iimp\/In\/Imax<\/strong> (suffisant) \u2192 <strong>Haut de la page<\/strong> (aussi bas que le permet la coordination) \u2192 <strong>SCCR\/sauvegarde<\/strong> \u2192 <strong>caract\u00e9ristiques d'entretien<\/strong>.<\/p>\n  <\/details>\n\n  <details style=\"border:1px solid #e5e7eb;border-radius:8px;padding:10px 12px;margin:10px 0;background:#fff;\">\n    <summary style=\"cursor:pointer;font-weight:600;color:#111827;\">Et si je ne peux m'offrir qu'une seule \u00e9tape aujourd'hui ?<\/summary>\n    <p style=\"margin:8px 0 0;color:#111827;line-height:1.8;\">Mettre le budget \u00e0 l'ordre du jour <strong>entr\u00e9e de service<\/strong> (Type 1 ou 1+2), puis ajouter le Type 2\/3 plus tard. Cela permet d'emp\u00eacher l'\u00e9nergie catastrophique de p\u00e9n\u00e9trer profond\u00e9ment dans l'installation.<\/p>\n  <\/details>\n\n  <details style=\"border:1px solid #e5e7eb;border-radius:8px;padding:10px 12px;margin:10px 0;background:#fff;\">\n    <summary style=\"cursor:pointer;font-weight:600;color:#111827;\">Comment la g\u00e9ographie modifie-t-elle ma sp\u00e9cification ?<\/summary>\n    <p style=\"margin:8px 0 0;color:#111827;line-height:1.8;\">Les corridors \u00e0 forte densit\u00e9 (par exemple, la c\u00f4te du Golfe, le centre de la Floride) justifient des taux d'occupation plus \u00e9lev\u00e9s. <em>Iimp\/In<\/em> et plus serr\u00e9 <em>Haut de la page<\/em> cibles. Utiliser les cartes NCEI\/Vaisala\/AEM pour quantifier les densit\u00e9s d'\u00e9clairs de r\u00e9f\u00e9rence pour les discussions avec l'AHJ ou les assurances.<\/p>\n  <\/details>\n<\/section>\n\n\n\n<section id=\"sources\" style=\"margin:24px 0 28px;\">\n  <h2 style=\"font-size:22px;line-height:1.3;margin:0 0 8px;color:#111827;\">Cr\u00e9dits et sources<\/h2>\n  <ul style=\"margin:0; padding-left:18px; color:#111827; line-height:1.9; font-size:16px; list-style:disc;\">\n    <li>IEC 61643-11 \/ 61643-31 (officielle) : <a href=\"https:\/\/webstore.iec.ch\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Boutique en ligne de la CEI<\/a><\/li>\n    <li>UL 1449 4e \u00e9d : <a href=\"https:\/\/www.intertek.com\/standards-updates\/ul1449-4th-edition\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Intertek<\/a> - <a href=\"https:\/\/www.se.com\/us\/en\/download\/document\/UL1449_4thEd_Overview\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">Schneider PDF<\/a><\/li>\n    <li>NEC 2023 (article 242) : <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" target=\"_blank\" rel=\"noopener\" style=\"color:#0ea5e9;text-decoration:none;\">NFPA<\/a><\/li>\n  <\/ul>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Updated: September 19, 2025 \u00b7 Reading time: ~18\u201322 min Selecting the correct Surge Protective Device (SPD) is among the highest-ROI decisions in LV distribution, PV\/ESS, EV charging, and industrial automation. This guide compiles standards-driven criteria (IEC\/UL\/NEC), placement rules, and BOM tips for both AC and DC systems. See the reference tables and sources at the [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":1513,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[42],"tags":[],"class_list":["post-1730","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-surge-protection-lightning-safety"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/1730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/comments?post=1730"}],"version-history":[{"count":3,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/1730\/revisions"}],"predecessor-version":[{"id":1737,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/posts\/1730\/revisions\/1737"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media\/1513"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/media?parent=1730"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/categories?post=1730"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/fr\/wp-json\/wp\/v2\/tags?post=1730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}