{"id":4363,"date":"2026-08-25T19:24:21","date_gmt":"2026-08-25T11:24:21","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=4363"},"modified":"2026-08-26T13:59:31","modified_gmt":"2026-08-26T05:59:31","slug":"g2r-63-din-rail-modular-automatic-transfer-switch-6a-63a","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/es\/product\/g2r-63-din-rail-modular-automatic-transfer-switch-6a-63a\/","title":{"rendered":"Interruptor de transferencia autom\u00e1tica modular para riel DIN G2R-63 de 6A a 63A"},"content":{"rendered":"<p><strong>G2R-63 DIN Rail Modular Automatic Transfer Switch<\/strong> provides reliable automatic changeover between a normal power source and a standby source. Designed for low-voltage AC systems, it helps maintain power continuity for residential, commercial, industrial and solar backup applications.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Fast automatic transfer in less than 50 ms<\/li>\n<li>Rated current options from 6A to 63A<\/li>\n<li>2P and 4P configurations for single-phase and three-phase systems<\/li>\n<li>Automatic and manual operating modes<\/li>\n<li>Over-voltage and under-voltage protection<\/li>\n<li>DIN rail modular design for compact installation<\/li>\n<li>Clear source and load status indication<\/li>\n<\/ul>\n<p><!-- G2R-63 Pure SVG Interactive Diagram --><\/p>\n<section id=\"g2r-svg-guide\" aria-labelledby=\"g2r-svg-title\">\n<style>\n#g2r-svg-guide{margin:36px 0;padding:30px 18px;border:1px solid #e5e7eb;border-radius:14px;background:#fff}#g2r-svg-guide *{box-sizing:border-box}.sg-head{text-align:center;margin-bottom:20px}.sg-head h2{margin:0 0 8px}.sg-head p,.sg-info p{margin:0;color:#5b6470}.sg-main{max-width:1100px;margin:auto}.sg-main svg,.sg-dim svg{width:100%;height:auto;display:block}.sg-device{fill:#fff;stroke:#242424;stroke-width:3}.sg-detail{fill:none;stroke:#4b5563;stroke-width:2}.sg-call{fill:none;stroke:#27272a;stroke-width:2.5;stroke-dasharray:8 6}.sg-point{fill:#cf1f0b;stroke:#fff;stroke-width:2}.sg-label{font:700 17px Arial,sans-serif;fill:#242424}.sg-small{font:600 13px Arial,sans-serif;fill:#4b5563}.sg-brand{font:800 22px Arial,sans-serif;fill:#d61f0c;letter-spacing:1px}.sg-part{cursor:pointer}.sg-part:focus{outline:none}.sg-part:hover .sg-call,.sg-part:focus .sg-call,.sg-part.active .sg-call{stroke:#cf1f0b;stroke-width:4;stroke-dasharray:none}.sg-part:hover .sg-label,.sg-part:focus .sg-label,.sg-part.active .sg-label{fill:#cf1f0b}.sg-info{max-width:780px;margin:18px auto 0;padding:16px 20px;border-left:4px solid #cf1f0b;background:#f8fafc;border-radius:7px}.sg-info h3{margin:0 0 6px;font-size:19px}.sg-lower{display:grid;grid-template-columns:1fr 1fr;gap:20px;max-width:1100px;margin:24px auto 0}.sg-card{border:1px solid #e5e7eb;border-radius:10px;padding:18px}.sg-card h3{text-align:center;margin:0 0 12px}.sg-spec{display:grid;grid-template-columns:1fr 1fr;gap:8px}.sg-spec span{padding:9px;background:#f8fafc;border-radius:6px}.sg-note{font-size:13px;color:#6b7280;text-align:center;margin:10px 0 0}\n@media(max-width:760px){#g2r-svg-guide{padding:22px 8px}.sg-main{overflow-x:auto}.sg-main svg{min-width:760px}.sg-lower{grid-template-columns:1fr}.sg-spec{grid-template-columns:1fr}.sg-label{font-size:16px}}\n<\/style>\n<div class=\"sg-head\">\n<h2 id=\"g2r-svg-title\">G2R-63 Connection &amp; Component Guide<\/h2>\n<p>Pure technical line drawing \u2014 select a callout to view its function.<\/p>\n<\/div>\n<div class=\"sg-main\"><svg viewBox=\"0 0 1100 760\" role=\"img\" aria-label=\"Interactive technical line diagram of KUANGYA G2R-63 automatic transfer switch\">\n<rect x=\"390\" y=\"55\" width=\"320\" height=\"650\" rx=\"8\" class=\"sg-device\"\/><line x1=\"550\" y1=\"55\" x2=\"550\" y2=\"705\" class=\"sg-detail\"\/><line x1=\"390\" y1=\"150\" x2=\"710\" y2=\"150\" class=\"sg-detail\"\/><line x1=\"390\" y1=\"255\" x2=\"710\" y2=\"255\" class=\"sg-detail\"\/><line x1=\"390\" y1=\"570\" x2=\"710\" y2=\"570\" class=\"sg-detail\"\/>\n<g class=\"sg-detail\"><rect x=\"415\" y=\"75\" width=\"120\" height=\"50\" rx=\"5\"\/><rect x=\"565\" y=\"75\" width=\"120\" height=\"50\" rx=\"5\"\/><circle cx=\"445\" cy=\"100\" r=\"13\"\/><circle cx=\"505\" cy=\"100\" r=\"13\"\/><circle cx=\"595\" cy=\"100\" r=\"13\"\/><circle cx=\"655\" cy=\"100\" r=\"13\"\/><rect x=\"415\" y=\"175\" width=\"120\" height=\"50\" rx=\"5\"\/><rect x=\"565\" y=\"175\" width=\"120\" height=\"50\" rx=\"5\"\/><circle cx=\"445\" cy=\"200\" r=\"13\"\/><circle cx=\"505\" cy=\"200\" r=\"13\"\/><circle cx=\"595\" cy=\"200\" r=\"13\"\/><circle cx=\"655\" cy=\"200\" r=\"13\"\/>\n<circle cx=\"438\" cy=\"315\" r=\"11\"\/><circle cx=\"438\" cy=\"350\" r=\"11\"\/><circle cx=\"438\" cy=\"500\" r=\"11\"\/><rect x=\"465\" y=\"375\" width=\"28\" height=\"55\" rx=\"4\"\/><rect x=\"510\" y=\"300\" width=\"150\" height=\"30\" rx=\"4\"\/><rect x=\"520\" y=\"345\" width=\"85\" height=\"145\" rx=\"8\"\/><rect x=\"535\" y=\"395\" width=\"75\" height=\"70\" rx=\"7\"\/><line x1=\"545\" y1=\"408\" x2=\"600\" y2=\"408\"\/><line x1=\"545\" y1=\"420\" x2=\"600\" y2=\"420\"\/><line x1=\"545\" y1=\"432\" x2=\"600\" y2=\"432\"\/><line x1=\"545\" y1=\"444\" x2=\"600\" y2=\"444\"\/><rect x=\"415\" y=\"605\" width=\"120\" height=\"55\" rx=\"5\"\/><rect x=\"565\" y=\"605\" width=\"120\" height=\"55\" rx=\"5\"\/><circle cx=\"445\" cy=\"632\" r=\"13\"\/><circle cx=\"505\" cy=\"632\" r=\"13\"\/><circle cx=\"595\" cy=\"632\" r=\"13\"\/><circle cx=\"655\" cy=\"632\" r=\"13\"\/><\/g>\n<text x=\"550\" y=\"322\" text-anchor=\"middle\" class=\"sg-brand\">KUANGYA<\/text><text x=\"550\" y=\"530\" text-anchor=\"middle\" class=\"sg-small\">G2R-63<\/text><text x=\"470\" y=\"145\" text-anchor=\"middle\" class=\"sg-small\">SOURCE II<\/text><text x=\"470\" y=\"247\" text-anchor=\"middle\" class=\"sg-small\">SOURCE I<\/text><text x=\"550\" y=\"690\" text-anchor=\"middle\" class=\"sg-small\">LOAD<\/text>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Backup Power Input (II)\" data-text=\"The upper source-II terminals receive the standby AC supply.\"><polyline points=\"390,100 285,100 230,75\" class=\"sg-call\"\/><circle cx=\"390\" cy=\"100\" r=\"7\" class=\"sg-point\"\/><text x=\"220\" y=\"72\" text-anchor=\"end\" class=\"sg-label\">Backup power input (II)<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Normal Power Input (I)\" data-text=\"The source-I terminals receive the normal AC supply.\"><polyline points=\"390,200 270,200 220,175\" class=\"sg-call\"\/><circle cx=\"390\" cy=\"200\" r=\"7\" class=\"sg-point\"\/><text x=\"210\" y=\"172\" text-anchor=\"end\" class=\"sg-label\">Normal power input (I)<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Source Status Indicators\" data-text=\"The two upper indicators identify normal and standby source status.\"><polyline points=\"438,332 290,332 225,300\" class=\"sg-call\"\/><circle cx=\"438\" cy=\"332\" r=\"7\" class=\"sg-point\"\/><text x=\"215\" y=\"297\" text-anchor=\"end\" class=\"sg-label\">Source I \/ II indicators<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Automatic \/ Manual Selector\" data-text=\"Select automatic changeover or local manual operation.\"><polyline points=\"465,402 290,402 225,380\" class=\"sg-call\"\/><circle cx=\"465\" cy=\"402\" r=\"7\" class=\"sg-point\"\/><text x=\"215\" y=\"377\" text-anchor=\"end\" class=\"sg-label\">Auto \/ Manual selector<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Transfer Position Indication\" data-text=\"The front marks show the selected transfer position.\"><polyline points=\"625,360 790,300 865,300\" class=\"sg-call\"\/><circle cx=\"625\" cy=\"360\" r=\"7\" class=\"sg-point\"\/><text x=\"875\" y=\"305\" class=\"sg-label\">Transfer position indication<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Manual Operating Handle\" data-text=\"The handle enables controlled local transfer when manual mode is selected.\"><polyline points=\"610,430 790,430 865,405\" class=\"sg-call\"\/><circle cx=\"610\" cy=\"430\" r=\"7\" class=\"sg-point\"\/><text x=\"875\" y=\"410\" class=\"sg-label\">Manual operating handle<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Load Status Indication\" data-text=\"The load indicator provides a visual output status reference.\"><polyline points=\"438,500 285,500 225,520\" class=\"sg-call\"\/><circle cx=\"438\" cy=\"500\" r=\"7\" class=\"sg-point\"\/><text x=\"215\" y=\"525\" text-anchor=\"end\" class=\"sg-label\">Load status indication<\/text><\/g>\n<g class=\"sg-part\" tabindex=\"0\" data-title=\"Load Output Terminals\" data-text=\"The lower terminals deliver the selected source to the downstream load.\"><polyline points=\"650,632 800,632 865,600\" class=\"sg-call\"\/><circle cx=\"650\" cy=\"632\" r=\"7\" class=\"sg-point\"\/><text x=\"875\" y=\"605\" class=\"sg-label\">Load output terminals<\/text><\/g>\n<\/svg><\/div>\n<div class=\"sg-info\" aria-live=\"polite\">\n<h3>Interactive component guide<\/h3>\n<p>Select a label or connection line to display its function.<\/p>\n<\/div>\n<div class=\"sg-lower\">\n<div class=\"sg-card sg-dim\">\n<h3>DIN Rail Mounting Diagram<\/h3>\n<p><svg viewBox=\"0 0 500 300\" role=\"img\" aria-label=\"DIN rail mounting line drawing\"><path d=\"M95 225h310v25H95zM145 210V70h210v140M170 210V95h160v115\" class=\"sg-device\"\/><path d=\"M195 225v-25h110v25M225 250v20h50v-20\" class=\"sg-detail\"\/><path d=\"M60 238h35M405 238h35\" class=\"sg-call\"\/><text x=\"250\" y=\"292\" text-anchor=\"middle\" class=\"sg-small\">35 mm DIN rail interface<\/text><path d=\"M250 35v45m-12-15 12 15 12-15\" class=\"sg-call\"\/><text x=\"250\" y=\"25\" text-anchor=\"middle\" class=\"sg-label\">Clip onto rail<\/text><\/svg><\/div>\n<div class=\"sg-card\">\n<h3>Reference Dimensions<\/h3>\n<div class=\"sg-spec\"><span><strong>Overall width:<\/strong> 94 mm<\/span><span><strong>Overall height:<\/strong> 78 mm<\/span><span><strong>Body height:<\/strong> 70 mm<\/span><span><strong>Rail opening:<\/strong> 35 mm<\/span><span><strong>Terminal span:<\/strong> 45 mm<\/span><span><strong>Reference torque:<\/strong> 2.5 N\u00b7m<\/span><\/div>\n<p class=\"sg-note\">Verify dimensions and tightening requirements for the ordered configuration.<\/p>\n<\/div>\n<\/div>\n<p><script>(function(){var r=document.getElementById('g2r-svg-guide');if(!r)return;var o=r.querySelector('.sg-info');function a(g){r.querySelectorAll('.sg-part').forEach(function(x){x.classList.toggle('active',x===g)});o.innerHTML='<\/p>\n<h3>'+g.dataset.title+'<\/h3>\n<p>'+g.dataset.text+'<\/p>\n<p>'}r.querySelectorAll('.sg-part').forEach(function(g){g.addEventListener('click',function(){a(g)});g.addEventListener('keydown',function(e){if(e.key==='Enter'||e.key===' '){e.preventDefault();a(g)}})})})();<\/script><br \/>\n<\/section>\n<h2>Technical Parameters<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<td>G2R-63<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>PC-class automatic transfer switch<\/td>\n<\/tr>\n<tr>\n<th>Rated Operating Current<\/th>\n<td>6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A<\/td>\n<\/tr>\n<tr>\n<th>Rated Operating Voltage<\/th>\n<td>AC 110V \/ AC 220V<\/td>\n<\/tr>\n<tr>\n<th>Frequency<\/th>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<th>Poles<\/th>\n<td>2P \/ 4P<\/td>\n<\/tr>\n<tr>\n<th>Rated Insulation Voltage<\/th>\n<td>690V<\/td>\n<\/tr>\n<tr>\n<th>Rated Impulse Withstand Voltage<\/th>\n<td>8kV<\/td>\n<\/tr>\n<tr>\n<th>Transfer Time<\/th>\n<td>&lt;50 ms<\/td>\n<\/tr>\n<tr>\n<th>Mechanical Life<\/th>\n<td>\u22658,000 operations<\/td>\n<\/tr>\n<tr>\n<th>Electrical Life<\/th>\n<td>\u22651,500 operations<\/td>\n<\/tr>\n<tr>\n<th>Mounting<\/th>\n<td>DIN rail<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How It Works<\/h2>\n<p>When the normal power source fails or moves outside the permitted voltage range, the G2R-63 automatically transfers the load to the standby power source. When normal power is restored, the switch returns the load according to its operating logic. A manual mode is also available for commissioning and maintenance.<\/p>\n<h2>Applications<\/h2>\n<ul>\n<li>Solar and generator backup systems<\/li>\n<li>Residential distribution boards<\/li>\n<li>Commercial buildings and offices<\/li>\n<li>Data, communication and monitoring equipment<\/li>\n<li>Industrial control and critical auxiliary circuits<\/li>\n<\/ul>\n<h2>Ordering Information<\/h2>\n<p>Select the required rated current, operating voltage and pole configuration when requesting a quotation. Contact KUANGYA for OEM labeling, packaging and project support.<\/p>\n<h2>FAQ<\/h2>\n<h3>What is the difference between the 2P and 4P versions?<\/h3>\n<p>The 2P version is typically used in single-phase systems, while the 4P version is designed for three-phase systems requiring neutral switching.<\/p>\n<h3>Can the switch operate manually?<\/h3>\n<p>Yes. The front selector supports automatic and manual operation.<\/p>\n<h3>Is it suitable for solar backup systems?<\/h3>\n<p>Yes. It can transfer a load between normal utility power and a compatible standby source such as a generator or solar backup supply.<\/p>\n<p><!-- G2R-63 inquiry-only display --><\/p>\n<style>.postid-4363 div.product .summary .price,.postid-4363 div.product form.cart,.postid-4363 .ct-sticky-add-to-cart{display:none!important}<\/style>\n<p><!-- G2R-63 Product and FAQ Schema --><br \/>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Product\",\"@id\":\"https:\/\/cnkuangya.com\/product\/g2r-63-din-rail-modular-automatic-transfer-switch-6a-63a\/#product\",\"name\":\"G2R-63 DIN Rail Modular Automatic Transfer Switch 6A\u201363A\",\"description\":\"Compact 2P\/4P DIN rail automatic transfer switch for 6A\u201363A AC systems, providing rapid automatic or manual changeover between normal and standby power.\",\"sku\":\"G2R-63\",\"mpn\":\"G2R-63\",\"brand\":{\"@type\":\"Brand\",\"name\":\"KUANGYA\"},\"manufacturer\":{\"@type\":\"Organization\",\"name\":\"Kuangya Electric\",\"url\":\"https:\/\/cnkuangya.com\/\"},\"category\":\"AC Transfer Switch\",\"url\":\"https:\/\/cnkuangya.com\/product\/g2r-63-din-rail-modular-automatic-transfer-switch-6a-63a\/\",\"image\":[\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/08\/kuangya-g2r-63-2p-4p-combined-v1.png\",\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/08\/kuangya-g2r-63-2p-front-v1.png\",\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/08\/kuangya-g2r-63-4p-solar-front-v1.png\",\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/08\/kuangya-g2r-63-rear-view-v1.png\"],\"offers\":{\"@type\":\"Offer\",\"url\":\"https:\/\/cnkuangya.com\/product\/g2r-63-din-rail-modular-automatic-transfer-switch-6a-63a\/\",\"priceCurrency\":\"USD\",\"price\":\"14.93\",\"availability\":\"https:\/\/schema.org\/InStock\",\"itemCondition\":\"https:\/\/schema.org\/NewCondition\",\"seller\":{\"@type\":\"Organization\",\"name\":\"Kuangya Electric\"}},\"additionalProperty\":[{\"@type\":\"PropertyValue\",\"name\":\"Rated Operating Current\",\"value\":\"6A\u201363A\"},{\"@type\":\"PropertyValue\",\"name\":\"Rated Operating Voltage\",\"value\":\"AC 110V \/ AC 220V\"},{\"@type\":\"PropertyValue\",\"name\":\"Frequency\",\"value\":\"50\/60Hz\"},{\"@type\":\"PropertyValue\",\"name\":\"Poles\",\"value\":\"2P \/ 4P\"},{\"@type\":\"PropertyValue\",\"name\":\"Rated Insulation Voltage\",\"value\":\"690V\"},{\"@type\":\"PropertyValue\",\"name\":\"Rated Impulse Withstand Voltage\",\"value\":\"8kV\"},{\"@type\":\"PropertyValue\",\"name\":\"Transfer Time\",\"value\":\"Less than 50 ms\"},{\"@type\":\"PropertyValue\",\"name\":\"Mounting\",\"value\":\"DIN rail\"},{\"@type\":\"PropertyValue\",\"name\":\"Operating Modes\",\"value\":\"Automatic \/ Manual\"}]},{\"@type\":\"FAQPage\",\"@id\":\"https:\/\/cnkuangya.com\/product\/g2r-63-din-rail-modular-automatic-transfer-switch-6a-63a\/#faq\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between the 2P and 4P versions?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The 2P version is typically used in single-phase systems, while the 4P version is designed for three-phase systems requiring neutral switching.\"}},{\"@type\":\"Question\",\"name\":\"Can the switch operate manually?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The front selector supports automatic and manual operation.\"}},{\"@type\":\"Question\",\"name\":\"Is it suitable for solar backup systems?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. It can transfer a load between normal utility power and a compatible standby source such as a generator or solar backup supply.\"}}]}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Compact 2P\/4P DIN rail automatic transfer switch for 6A\u201363A AC systems. Provides rapid automatic or manual changeover between normal and standby power, with clear status indication and voltage protection.<\/p>","protected":false},"featured_media":4364,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[32],"product_tag":[107,104,105,106,108],"class_list":["post-4363","product","type-product","status-publish","has-post-thumbnail","product_cat-ac-transfer-switch","product_tag-63a-ats","product_tag-automatic-transfer-switch","product_tag-din-rail-ats","product_tag-dual-power-transfer-switch","product_tag-solar-backup-switch","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/product\/4363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/comments?post=4363"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/media\/4364"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/media?parent=4363"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/product_brand?post=4363"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/product_cat?post=4363"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/product_tag?post=4363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}