{"id":2279,"date":"2025-12-15T09:19:15","date_gmt":"2025-12-15T09:19:15","guid":{"rendered":"https:\/\/cnkuangya.com\/?p=2279"},"modified":"2025-12-16T01:50:46","modified_gmt":"2025-12-16T01:50:46","slug":"matching-pv-combiner-box","status":"publish","type":"post","link":"https:\/\/cnkuangya.com\/es\/blog\/matching-pv-combiner-box\/","title":{"rendered":"Valores de corriente y tensi\u00f3n de la caja combinadora fotovoltaica"},"content":{"rendered":"<p>In a solar photovoltaic (PV) system, the combiner box plays a central role in consolidating power and ensuring safety. It&#8217;s a junction box where the output of multiple solar strings are connected in parallel, combining their current before sending it to the inverter. More importantly, it houses the critical overcurrent protection devices (fuses or circuit breakers) that protect the system&#8217;s wiring and components from potentially dangerous faults.<img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"1118\" class=\"wp-image-2282\" style=\"width: 750px;\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-scaled.jpg\" alt=\"\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-scaled.jpg 1717w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-201x300.jpg 201w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-687x1024.jpg 687w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-768x1145.jpg 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-1030x1536.jpg 1030w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-1374x2048.jpg 1374w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-8x12.jpg 8w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-300x447.jpg 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/111-600x894.jpg 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/p>\n\n\n\n<p>Dimensionar correctamente su <a href=\"https:\/\/cnkuangya.com\/es\/pv-combiner-box\/\">Caja combinadora FV<\/a> and its internal components is not just a best practice\u2014it&#8217;s a fundamental requirement for a safe, reliable, and code-compliant installation. An undersized component can lead to fire hazards, while an oversized one may fail to provide adequate protection.<\/p>\n\n\n\n<p>This guide will walk you through the essential steps for matching your combiner box&#8217;s voltage and current ratings to your specific solar array, with a focus on the requirements outlined in the National Electrical Code (NEC). We will cover:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Principios b\u00e1sicos de seguridad del art\u00edculo 690 de NEC<\/li>\n\n\n\n<li>C\u00e1lculo de la tensi\u00f3n m\u00e1xima del sistema en funci\u00f3n de las condiciones del emplazamiento<\/li>\n\n\n\n<li>Dimensionamiento de los fusibles de ramal de CC y de la protecci\u00f3n principal contra sobreintensidades<\/li>\n\n\n\n<li><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"500\" class=\"wp-image-2280\" style=\"width: 750px;\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring.webp\" alt=\"\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring.webp 700w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-300x200.webp 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-18x12.webp 18w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/Open-solar-combiner-box-showing-internal-wiring-600x400.webp 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/cdn.gooo.ai\/web-images\/f98a9597b933747a0375ac33ca63d7b9aa7aa76297f229a1af932c02b15e0289\" alt=\"Diagrama que muestra los distintos componentes de una caja combinadora fotovoltaica, incluida la entrada de CC, los fusibles, las barras colectoras y el circuito de salida.\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">La base: Comprender el art\u00edculo 690 del NEC<\/h3>\n\n\n\n<p>Para cualquier instalaci\u00f3n fotovoltaica en Estados Unidos, el art\u00edculo 690 del NEC es la m\u00e1xima autoridad. Esta secci\u00f3n del c\u00f3digo est\u00e1 dedicada espec\u00edficamente a los sistemas fotovoltaicos solares y aborda las caracter\u00edsticas \u00fanicas y los peligros potenciales de la generaci\u00f3n de energ\u00eda de CC. Proporciona el marco para todo, desde el cableado y la conexi\u00f3n a tierra hasta los medios de desconexi\u00f3n y la protecci\u00f3n contra sobrecorriente. Cumplir el art\u00edculo 690 es esencial para garantizar que su sistema sea seguro y pase la inspecci\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parte 1: Adaptaci\u00f3n de la tensi\u00f3n del sistema fotovoltaico<\/h3>\n\n\n\n<p>El primer y m\u00e1s importante par\u00e1metro a determinar es la tensi\u00f3n m\u00e1xima del sistema. Todos los componentes de un circuito, desde los cables hasta los fusibles y la propia caja combinadora, deben tener una tensi\u00f3n nominal igual o superior a la tensi\u00f3n m\u00e1xima que podr\u00edan experimentar.<\/p>\n\n\n\n<p>In a PV system, the maximum voltage is determined by the number of modules in a series string and their open-circuit voltage (Voc), found on the module&#8217;s datasheet. However, voltage is inversely proportional to temperature; a solar panel&#8217;s voltage is highest on the coldest possible day. NEC requires you to calculate the maximum voltage for the lowest expected ambient temperature at your site.<\/p>\n\n\n\n<p><strong>C\u00f3mo calcular la tensi\u00f3n m\u00e1xima del sistema:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Encuentra el Voc:<\/strong> Look up the Open-Circuit Voltage (Voc) on your solar module&#8217;s datasheet.<\/li>\n\n\n\n<li><strong>Determinar la temperatura m\u00e1s baja:<\/strong> Busque la temperatura m\u00ednima r\u00e9cord de su localidad. A menudo puedes encontrarla en los datos meteorol\u00f3gicos locales o en las tablas de temperatura de dise\u00f1o de ASHRAE.<\/li>\n\n\n\n<li><strong>Hallar el factor de correcci\u00f3n de la temperatura:<\/strong> La hoja de datos del m\u00f3dulo proporcionar\u00e1 un coeficiente de temperatura para Voc, expresado como porcentaje o V\/\u00b0C. Util\u00edcelo para hallar el factor de correcci\u00f3n para su temperatura m\u00e1s baja en relaci\u00f3n con la temperatura de la condici\u00f3n de prueba est\u00e1ndar (STC) de 25\u00b0C. El NEC proporciona tablas en 690.7 para un c\u00e1lculo simplificado.<\/li>\n\n\n\n<li><strong>Calcular Voc. corregido<\/strong> <code>Voc corregido = Voc \u00d7 [1 + (Temp m\u00e1s baja \u00b0C - 25\u00b0C) \u00d7 (Coeficiente Voc Temp %\/\u00b0C)].<\/code><\/li>\n\n\n\n<li><strong>Calcule la tensi\u00f3n m\u00e1xima del sistema:<\/strong> <code>Tensi\u00f3n m\u00e1xima del sistema = Voc corregido \u00d7 N\u00famero de m\u00f3dulos en serie<\/code><\/li>\n<\/ol>\n\n\n\n<p><strong>Ejemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vocal del m\u00f3dulo: 48,5 V<\/li>\n\n\n\n<li>Temperatura m\u00ednima del emplazamiento: -10\u00b0C<\/li>\n\n\n\n<li>N\u00famero de m\u00f3dulos por cadena: 12<\/li>\n\n\n\n<li>Coeficiente de temperatura Voc: -0,28%\/\u00b0C<\/li>\n\n\n\n<li>Voc corregido = <code>48.5V \u00d7 [1 + (-10 - 25) \u00d7 (-0.0028)]<\/code> = <code>48.5V \u00d7 [1 + (-35 \u00d7 -0.0028)]<\/code> = <code>48.5V \u00d7 1.098<\/code> = 53.25V<\/li>\n\n\n\n<li><strong>Tensi\u00f3n m\u00e1xima del sistema<\/strong> = <code>53.25V \u00d7 12<\/code> = <strong>639V<\/strong><\/li>\n<\/ul>\n\n\n\n<p>En este caso, el sistema requiere una caja combinadora, fusibles y disyuntores de al menos 639V. Por lo tanto, deber\u00eda seleccionar componentes de una clase est\u00e1ndar de 1000 V CC, ya que los componentes de 600 V ser\u00edan insuficientes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Segunda parte: <a href=\"https:\/\/cnkuangya.com\/es\/pv-combiner-box\/\">Caja combinadora FV<\/a> Dimensionamiento y fusibles de CC<\/h3>\n\n\n\n<p>Tras determinar la tensi\u00f3n nominal, el siguiente paso es dimensionar los dispositivos de protecci\u00f3n contra sobrecorriente (OCPD), que suelen ser fusibles. El objetivo principal de los fusibles de cadena es proteger contra la corriente inversa. Un fallo en un ramal puede hacer que otros ramales se retroalimenten, creando una situaci\u00f3n de sobrecorriente peligrosa.<\/p>\n\n\n\n<p>Seg\u00fan la norma NEC 690.9, los fusibles a nivel de cadena son necesarios siempre que haya <strong>tres o m\u00e1s cadenas en paralelo<\/strong>. With only two strings, the reverse current potential is not high enough to exceed the module&#8217;s fuse rating, so fuses are not required by code (though they are still sometimes used as a disconnecting means).<\/p>\n\n\n\n<p><strong>C\u00f3mo dimensionar los fusibles de hilo:<\/strong><\/p>\n\n\n\n<p>The NEC requires that the fuse be rated to handle continuous duty and potential irradiance spikes. This is accomplished by multiplying the module&#8217;s Short-Circuit Current (Isc) by a factor of 1.56.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Factor 1,25<\/strong> para carga continua (circuitos que pueden funcionar durante m\u00e1s de 3 horas).<\/li>\n\n\n\n<li><strong>Factor 1,25<\/strong> for potential &#8220;irradiance enhancement&#8221; where sun exposure can exceed the standard 1000 W\/m\u00b2.<\/li>\n\n\n\n<li><code>1.25 \u00d7 1.25 = 1.56<\/code><\/li>\n<\/ul>\n\n\n\n<p><strong>F\u00f3rmula de clasificaci\u00f3n de fusibles:<\/strong> <code>Capacidad m\u00ednima del fusible \u2265 Isc del m\u00f3dulo \u00d7 1,56<\/code><\/p>\n\n\n\n<p>Una vez calculado este m\u00ednimo, se selecciona el tama\u00f1o de fusible est\u00e1ndar inmediatamente superior.<\/p>\n\n\n\n<p><strong>Limitaci\u00f3n crucial: Capacidad m\u00e1xima de los fusibles en serie<\/strong>\\<br>Every solar module has a &#8220;Maximum Series Fuse Rating&#8221; listed on its datasheet. This value is an absolute limit. <strong>El tama\u00f1o del fusible calculado no debe superar esta capacidad.<\/strong> Si es as\u00ed, el dise\u00f1o del sistema es defectuoso, lo que significa que el m\u00f3dulo elegido no puede utilizarse con tantas cadenas en paralelo.<\/p>\n\n\n\n<p><strong>Ejemplo:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>M\u00f3dulo Isc: 10.5A<\/li>\n\n\n\n<li>Capacidad m\u00e1xima del fusible serie del m\u00f3dulo: 20 A<\/li>\n\n\n\n<li>Capacidad m\u00ednima del fusible = <code>10.5A \u00d7 1.56<\/code> = <strong>16.38A<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Bas\u00e1ndose en este c\u00e1lculo, elegir\u00eda la siguiente talla est\u00e1ndar, que es una <strong>20A<\/strong> fuse. Since 20A is equal to the module&#8217;s maximum series fuse rating, this is a valid selection. If the calculation had resulted in 21A, you would not be able to use a 25A fuse, and the design would need to be re-evaluated.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/cdn.gooo.ai\/web-images\/357e85dc73b217fa84fb935d7868800fccfd950772178c1989038765798e398e\" alt=\"Caja del combinador solar abierta que muestra el cableado interno, las barras colectoras y los portafusibles.\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Parte 3: Coordinaci\u00f3n de la protecci\u00f3n contra sobreintensidades<\/h3>\n\n\n\n<p>La coordinaci\u00f3n de la protecci\u00f3n garantiza que, en caso de fallo, se abra primero el OCPD correcto. Si se produce un fallo en una sola cadena, el fusible de la cadena individual debe fundirse, aislando s\u00f3lo esa cadena sin desconectar todo el grupo. El OCPD principal en la salida de la caja del combinador s\u00f3lo debe dispararse si se produce un fallo importante en los conductores principales que conducen al inversor.<\/p>\n\n\n\n<p>Esto se consigue asegurando que el dispositivo aguas abajo tenga una potencia inferior a la del dispositivo aguas arriba.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Componente<\/strong><\/th><th><strong>Prop\u00f3sito<\/strong><\/th><th><strong>Regla general de dimensionamiento<\/strong><\/th><th><strong>Referencia NEC<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Fusible de cadena<\/strong><\/td><td>Protege las cadenas individuales de los fallos de corriente inversa de otras cadenas.<\/td><td><code>Isc \u00d7 1,56<\/code> (y debe ser \u2264 Capacidad m\u00e1xima del fusible del m\u00f3dulo)<\/td><td><code>690.9(A)<\/code><\/td><\/tr><tr><td><strong>Combinador principal OCPD<\/strong><\/td><td>Protege el cable de salida principal desde la caja combinadora hasta el inversor.<\/td><td>Suma de todos los valores nominales de los fusibles de cadena, redondeada al tama\u00f1o de disyuntor est\u00e1ndar m\u00e1s pr\u00f3ximo. O <code>(Isc total \u00d7 1,25)<\/code> y seleccione la siguiente talla OCPD est\u00e1ndar superior.<\/td><td><code>690.9(A)<\/code> &amp; <code>240.4<\/code><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Preguntas m\u00e1s frecuentes (FAQ)<\/h3>\n\n\n\n<p><strong>\u00bfNecesito fusibles s\u00f3lo para dos cadenas en paralelo?<\/strong>\\<br>No. According to NEC 690.9, overcurrent protection is only required when there are three or more strings in parallel. With two strings, the maximum fault current that one string can source to the other is limited to the Isc of one string, which is below the module&#8217;s maximum fuse rating.<\/p>\n\n\n\n<p><strong>\u00bfPuedo utilizar fusibles o disyuntores de CA para circuitos de CC?<\/strong>\\<br>No, debe utilizar componentes espec\u00edficamente dise\u00f1ados para circuitos de CC. Los arcos de CC son mucho m\u00e1s dif\u00edciles de extinguir que los de CA. Es probable que un dispositivo para CA no pueda interrumpir de forma segura un fallo de CC, lo que supondr\u00eda un riesgo importante de incendio y de seguridad.<\/p>\n\n\n\n<p><strong>\u00bfQu\u00e9 ocurre si instalo un fusible de tama\u00f1o incorrecto?<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Demasiado peque\u00f1o:<\/strong> The fuse will be subject to &#8220;nuisance tripping,&#8221; blowing under normal operating conditions (e.g., on a cool, very sunny day), causing unnecessary system downtime.<\/li>\n\n\n\n<li><strong>Demasiado grande:<\/strong> A fuse that is too large (especially one exceeding the module&#8217;s Maximum Series Fuse Rating) will not protect the module from damaging reverse currents. This can lead to module failure and creates a fire risk.<\/li>\n<\/ul>\n\n\n\n<p><strong>\u00bfPor qu\u00e9 se utiliza el multiplicador 1,56 para el dimensionamiento?<\/strong>\\<br>It&#8217;s a combined safety factor required by the NEC. It consists of two separate 1.25 multipliers: one to account for the fact that solar circuits are considered &#8220;continuous loads&#8221; (running at max current for more than 3 hours), and a second to account for irradiance levels that can exceed standard test conditions, causing current to rise temporarily above the rated Isc. (1.25 x 1.25 = 1.56).<\/p>\n\n\n\n<p><strong>\u00bfQu\u00e9 es el \u201cvalor m\u00e1ximo de fusible serie\u201d de un m\u00f3dulo?<\/strong>\\<br>Se trata de una clasificaci\u00f3n de seguridad determinada por el fabricante del m\u00f3dulo y certificada por UL. Especifica la corriente m\u00e1xima que el m\u00f3dulo puede soportar sin sufrir da\u00f1os cuando se ve sometido a una corriente inversa. Nunca debe instalar un fusible u OCPD con un valor nominal superior a este valor.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"1024\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-687x1024.jpg\" alt=\"\" class=\"wp-image-2281\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-687x1024.jpg 687w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-201x300.jpg 201w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-768x1145.jpg 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-1030x1536.jpg 1030w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-1374x2048.jpg 1374w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-8x12.jpg 8w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-300x447.jpg 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-600x894.jpg 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/12\/7a0f6fb723ce36e5fbc3ff66ba0b6fdba0910b6bde5a3b55e8e147d79edab240-scaled.jpg 1717w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Conclusi\u00f3n<\/h3>\n\n\n\n<p>Matching a PV combiner box&#8217;s current and voltage ratings is a systematic process guided by engineering principles and the strict safety standards of the NEC. The core takeaways are:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Primero la tensi\u00f3n:<\/strong> Determine siempre la tensi\u00f3n m\u00e1xima del sistema utilizando la temperatura m\u00e1s baja prevista para su emplazamiento. Todos los componentes deben ser aptos para esta tensi\u00f3n.<\/li>\n\n\n\n<li><strong>Segundo actual:<\/strong> Size string fuses based on the module&#8217;s Isc and the 1.56x multiplier, but never exceed the module&#8217;s Maximum Series Fuse Rating.<\/li>\n\n\n\n<li><strong>El c\u00f3digo es la clave:<\/strong> When in doubt, defer to NEC Article 690 and the manufacturer&#8217;s datasheets for all components.<\/li>\n<\/ol>\n\n\n\n<p>By following these guidelines, you can ensure your solar array&#8217;s combiner box is sized safely, reliably, and professionally, forming a robust foundation for your entire PV system.<\/p>","protected":false},"excerpt":{"rendered":"<p>In a solar photovoltaic (PV) system, the combiner box plays a central role in consolidating power and ensuring safety. It&#8217;s a junction box where the output of multiple solar strings are connected in parallel, combining their current before sending it to the inverter. More importantly, it houses the critical overcurrent protection devices (fuses or circuit [&hellip;]<\/p>","protected":false},"author":4,"featured_media":2285,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[35],"tags":[],"class_list":["post-2279","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/posts\/2279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/comments?post=2279"}],"version-history":[{"count":1,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/posts\/2279\/revisions"}],"predecessor-version":[{"id":2283,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/posts\/2279\/revisions\/2283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/media\/2285"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/media?parent=2279"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/categories?post=2279"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/es\/wp-json\/wp\/v2\/tags?post=2279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}