{"id":1575,"date":"2025-09-16T09:37:52","date_gmt":"2025-09-16T09:37:52","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1575"},"modified":"2025-09-22T09:13:26","modified_gmt":"2025-09-22T09:13:26","slug":"rccb-63a-30ma-vml01","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/de\/product\/rccb-63a-30ma-vml01\/","title":{"rendered":"RCCB 63A 30mA VML01 - Fehlerstrom-Schutzschalter"},"content":{"rendered":"<div class=\"product-description\">\n<h2>\u00dcbersicht<\/h2>\n<p>The VML01 <strong>rccb 63a 30ma<\/strong> detects earth leakage and disconnects the circuit before harm occurs,<br \/>\nhelping prevent electric shock and fire hazards caused by insulation faults. It is available in 2-pole and 4-pole<br \/>\nversions for single-phase and three-phase boards and is suitable for housing, tertiary, and light-industrial use.<\/p>\n<h2>Wesentliche Merkmale<\/h2>\n<ul>\n<li>Pole: <strong>2P \/ 4P<\/strong><\/li>\n<li><strong>Nennstrom (In):<\/strong> 16, 25, 32, 40, 63, 80, 100 A<\/li>\n<li><strong>Nennempfindlichkeit (I\u0394n):<\/strong> 10 \/ 30 \/ 100 \/ 300 mA<\/li>\n<li><strong>Nennspannung (Ue):<\/strong> 240 V~ (2P) \/ 415 V~ (4P)<\/li>\n<li><strong>Isolationsspannung (Ui):<\/strong> 500 V | \u00a0 <strong>H\u00e4ufigkeit:<\/strong> 50\/60 Hz<\/li>\n<li><strong>Reste machen &amp; brechen (I\u0394m):<\/strong> 500 \/ 630 \/ 800 \/ 1000 A (per In group)<\/li>\n<li><strong>Bedingter Kurzschluss (Inc = I\u0394c):<\/strong> 6000 A \/ 10000 A (with upstream SCPD)<\/li>\n<li><strong>Impulswiderstand (Uimp):<\/strong> 6 kV<\/li>\n<li><strong>Dielektrische Pr\u00fcfung:<\/strong> 2.5 kV for 1 min (power frequency)<\/li>\n<li><strong>Klemmenschutz:<\/strong> IP20<\/li>\n<li><strong>Terminal capacity (cable):<\/strong> 25-35 mm\u00b2<\/li>\n<li><strong>Anzugsdrehmoment:<\/strong> 2,5 N-m<\/li>\n<li><strong>Environmental limits:<\/strong> \u221225 \u00b0C \u2026 +55 \u00b0C (ambient); \u221240 \u00b0C \u2026 +70 \u00b0C (storage)<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>Standard<\/th>\n<th>IEC\/EN 61008-1<\/th>\n<\/tr>\n<tr>\n<td>Model No.<\/td>\n<td>VML01<\/td>\n<\/tr>\n<tr>\n<td>Pole<\/td>\n<td>2P, 4P<\/td>\n<\/tr>\n<tr>\n<td>Nennstrom (In)<\/td>\n<td>16A, 25A, 32A, 40A, 63A, 80A, 100A<\/td>\n<\/tr>\n<tr>\n<td>Nennempfindlichkeit (I\u0394n)<\/td>\n<td>10 mA, 30 mA, 100 mA, 300 mA<\/td>\n<\/tr>\n<tr>\n<td>Nennspannung (Ue)<\/td>\n<td>2P: 240 V~; 4P: 415 V~<\/td>\n<\/tr>\n<tr>\n<td>Isolationsspannung (Ui)<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>Nennfrequenz<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Reste machen &amp; brechen (I\u0394m)<\/td>\n<td>500 A (In 16\u201340 A); 630 A (In 63 A); 800 A (In 80 A); 1000 A (In 100 A)<\/td>\n<\/tr>\n<tr>\n<td>Bedingter Kurzschluss (Inc = I\u0394c)<\/td>\n<td>6000 A; 10000 A (mit vorgeschaltetem SCPD)<\/td>\n<\/tr>\n<tr>\n<td>Impulswiderstand (Uimp)<\/td>\n<td>6 kV<\/td>\n<\/tr>\n<tr>\n<td>Dielektrische Pr\u00fcfung<\/td>\n<td>2.5 kV (1 min, power frequency)<\/td>\n<\/tr>\n<tr>\n<td>Schutzart der Klemmen<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature<\/td>\n<td>-25 \u00b0C bis +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Lagertemperatur<\/td>\n<td>-40 \u00b0C bis +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Terminal capacity (cable)<\/td>\n<td>25-35 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Anzugsdrehmoment<\/td>\n<td>2,5 N-m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Anwendungen<\/h2>\n<ul>\n<li>Three-phase panels using a <strong>rccb 63a 30ma<\/strong> (4P) for additional personal protection<\/li>\n<li>Single-phase boards (2P) in residential and commercial buildings<\/li>\n<li>Installations coordinated with upstream SCPD for 6\/10 kA conditional rating<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"\/images\/rccb-vml01.jpg\" alt=\"rccb 63a 30ma VML01 Kuangya 2P\/4P 16\u2013100A 10\/30\/100\/300 mA\" \/><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"277\" data-end=\"382\">\n<p data-start=\"279\" data-end=\"382\">Kuangya VML01 <strong data-start=\"293\" data-end=\"310\">rccb 63a 30ma<\/strong> for residential, commercial, and light-industrial distribution boards<\/p>\n<\/li>\n<li data-start=\"383\" data-end=\"485\">\n<p data-start=\"385\" data-end=\"485\">2P \/ 4P options; In 16\u2013100 A; I\u0394n 10\/30\/100\/300 mA; Ue 240 V (2P) \/ 415 V (4P); Ui 500 V; 50\/60 Hz<\/p>\n<\/li>\n<li data-start=\"486\" data-end=\"579\">\n<p data-start=\"488\" data-end=\"579\">Uimp 6 kV; conditional short-circuit Inc = I\u0394c 6\/10 kA (with upstream SCPD); IP20 terminals<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1818,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-1575","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/product\/1575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/comments?post=1575"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/media\/1818"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/media?parent=1575"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/product_brand?post=1575"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/product_cat?post=1575"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/product_tag?post=1575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}