{"id":4487,"date":"2026-09-08T13:08:59","date_gmt":"2026-09-08T05:08:59","guid":{"rendered":"https:\/\/cnkuangya.com\/?p=4487"},"modified":"2026-09-21T13:51:29","modified_gmt":"2026-09-21T05:51:29","slug":"dc-circuit-breaker-sample-approval-checklist","status":"publish","type":"post","link":"https:\/\/cnkuangya.com\/de\/blog\/dc-circuit-breaker-sample-approval-checklist\/","title":{"rendered":"DC Circuit Breaker Sample Approval Checklist"},"content":{"rendered":"<p>DC circuit breaker sample approval starts by confirming that its exact model, documentation, installation details and evaluation results all describe the same configuration. Then record that configuration as the reference for production orders.<\/p>\n<p>A sample that fits a panel is only a starting point. OEM buyers, distributors and panel builders also need evidence that the offered device suits the intended application and that future deliveries can be checked against a documented specification.<\/p>\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b.png\" alt=\"KUANGYA KYB1Z-63H DC circuit breaker product illustration\" class=\"wp-image-3938\" width=\"1295\" height=\"679\" loading=\"lazy\" style=\"max-width:100%;height:auto\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b.png 1295w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b-300x157.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b-1024x537.png 1024w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b-768x403.png 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b-18x9.png 18w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2026\/07\/ce68c69c-cdd3-4530-a774-1decfc119e2b-600x315.png 600w\" sizes=\"auto, (max-width: 1295px) 100vw, 1295px\" \/><figcaption>KUANGYA KYB1Z-63H DC circuit breaker. Confirm the exact sample model and configuration against its current documentation.<\/figcaption><\/figure>\n<h2>1. Define the application before requesting samples<\/h2>\n<p>Send the supplier a short application brief. Include the maximum DC circuit voltage, operating-current requirements, installation environment, available panel space and the protective-device requirements established by your engineering team. State whether the device is intended for a PV circuit, battery circuit or another DC application.<\/p>\n<p>Record the required pole arrangement, connection diagram, current direction and auxiliary accessories. Ask the supplier to identify the exact configuration offered, including model suffixes. Do not accept a general product-family brochure as the complete sample specification.<\/p>\n<p>For a starting point when comparing available configurations, browse the <a href=\"https:\/\/cnkuangya.com\/de\/dc-mcb\/\">Kuangya DC MCB product range<\/a>. Final selection should follow the exact model documentation and project requirements.<\/p>\n<h2>2. Build one document pack for each sample configuration<\/h2>\n<p>Assign every sample a reference number and keep its documents together. A simple spreadsheet can link the sample reference to the supplier model, drawing revision, evaluation record and approval decision.<\/p>\n<div role=\"region\" aria-label=\"Sample approval reference table\" tabindex=\"0\" style=\"max-width:100%;overflow-x:auto;margin:1.5em 0\">\n<table style=\"width:100%;min-width:480px\">\n<thead>\n<tr>\n<th scope=\"col\">Item to request<\/th>\n<th scope=\"col\">What the buyer should record<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Current datasheet<\/td>\n<td>Exact model, ratings, revision and date<\/td>\n<\/tr>\n<tr>\n<td>Installation instructions<\/td>\n<td>Connection arrangement, polarity requirements, terminal data and mounting instructions<\/td>\n<\/tr>\n<tr>\n<td>Dimension drawing<\/td>\n<td>Overall size, mounting details and access space<\/td>\n<\/tr>\n<tr>\n<td>Certification evidence<\/td>\n<td>Issuer, reference number, covered model and rating scope<\/td>\n<\/tr>\n<tr>\n<td>Relevant test evidence<\/td>\n<td>Sample identity, configuration, test conditions, results and report reference<\/td>\n<\/tr>\n<tr>\n<td>Marking and packaging artwork<\/td>\n<td>Model identification, batch identification and artwork revision<\/td>\n<\/tr>\n<tr>\n<td>Quotation<\/td>\n<td>The same model and accessories as the sample, with exclusions stated<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>If two documents disagree, request a corrected and consistent pack before approval. Avoid assuming that a value for another model also applies to the sample.<\/p>\n<h2>3. Verify certification claims against the offered model<\/h2>\n<p>When a supplier claims UL certification, use the official <a href=\"https:\/\/www.ul.com\/software\/product-sourcing-and-certifications-database\" rel=\"noopener\">UL Product iQ information page<\/a> to locate the verification service. Compare the resulting record with the supplier identity and the offered product configuration.<\/p>\n<p>For other claimed certifications, ask for the issuing body&#8217;s verification route. A logo on a catalogue or a link to a standard&#8217;s description does not establish that the supplied model is covered. If the record is unclear, ask the issuer or supplier to resolve the discrepancy.<\/p>\n<p>Keep a dated record of what was checked. Where private-label branding is involved, ask how the proposed brand and model identification relate to the supporting documentation before approving artwork.<\/p>\n<h2>4. Separate receiving inspection from electrical qualification<\/h2>\n<p>Receiving inspection can identify the wrong model, damaged packaging, missing accessories or inconsistent markings. Compare the sample with the approved drawing and document pack, and photograph the relevant identification details.<\/p>\n<p>Electrical qualification is a separate engineering activity. Your qualified engineering team or testing laboratory should define the required tests, conditions and acceptance limits using the applicable product requirements and manufacturer instructions. Record which evidence comes from supplier reports and which checks were performed independently.<\/p>\n<p>Do not use improvised short-circuit or high-voltage tests to qualify a sample. A basic mechanical check does not establish interrupting capacity or suitability for the intended DC circuit.<\/p>\n<p>For project selection questions, also see the <a href=\"https:\/\/cnkuangya.com\/de\/blog\/dc-circuit-breaker-sizing-for-solar\/\">DC circuit breaker sizing guide<\/a>.<\/p>\n<h2>5. Use a clear approval record<\/h2>\n<div role=\"region\" aria-label=\"Sample approval reference table\" tabindex=\"0\" style=\"max-width:100%;overflow-x:auto;margin:1.5em 0\">\n<table style=\"width:100%;min-width:480px\">\n<thead>\n<tr>\n<th scope=\"col\">Review area<\/th>\n<th scope=\"col\">Evidence to retain<\/th>\n<th scope=\"col\">Reason to hold approval<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product identity<\/td>\n<td>Model, suffixes, sample reference and photographs<\/td>\n<td>Sample and quotation describe different configurations<\/td>\n<\/tr>\n<tr>\n<td>Dokumentation<\/td>\n<td>Dated datasheet, drawing and instructions<\/td>\n<td>Missing or contradictory specifications<\/td>\n<\/tr>\n<tr>\n<td>Installation fit<\/td>\n<td>Fit-check record against the intended panel design<\/td>\n<td>Mounting, access or connection details remain unresolved<\/td>\n<\/tr>\n<tr>\n<td>Electrical qualification<\/td>\n<td>Engineering review and required test reports<\/td>\n<td>Required evidence is missing or fails agreed criteria<\/td>\n<\/tr>\n<tr>\n<td>Claimed certification<\/td>\n<td>Verification record for the offered scope<\/td>\n<td>Model or rating coverage cannot be confirmed<\/td>\n<\/tr>\n<tr>\n<td>Production consistency<\/td>\n<td>Approved reference documents and change process<\/td>\n<td>Supplier has not confirmed the production reference<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Use explicit outcomes such as <strong>approved for the stated configuration<\/strong>, <strong>on hold pending listed evidence<\/strong>, oder <strong>rejected with reasons<\/strong>. Name the reviewer and date the decision.<\/p>\n<h2>6. Connect sample approval to the production order<\/h2>\n<p>Retain a reference sample where practical, together with its approved documents. Specify the model, accessories and document revisions in the purchase order or agreed technical attachment.<\/p>\n<p>Ask the supplier to notify you before proposed changes to the approved configuration, relevant materials, markings or manufacturing arrangements. Define who reviews those changes and when a replacement sample or additional evidence is needed.<\/p>\n<p>Agree on how delivery batches will be identified and which records will accompany them. Set the incoming inspection and sampling plan with your quality team; one accepted sample does not demonstrate the quality of every future unit.<\/p>\n<h2>7. Copy this sample request template<\/h2>\n<pre style=\"white-space:pre-wrap;overflow-wrap:anywhere\"><code>Subject: DC circuit breaker sample request for OEM evaluation\n\nApplication and destination country:\nMaximum DC circuit voltage:\nOperating-current requirements:\nEngineering-specified protection requirements:\nRequired pole and connection arrangement:\nCurrent-direction requirements:\nInstallation environment and available space:\nRequired accessories and certification:\nSample quantity and estimated production quantity:\nTarget evaluation and delivery dates:\nBranding and packaging requirements:\n\nPlease identify the exact offered model and provide the current datasheet, dimension drawing, installation instructions, certification evidence, available relevant test reports, sample cost, lead time, production quotation, batch identification and change-notification process.<\/code><\/pre>\n<h2>Interactive Sample Approval Worksheet<\/h2>\n<p>Select a result and enter evidence for each check. Answers are temporary: this worksheet does not submit or permanently save them. Copy your notes before leaving. Any unresolved applicable requirement keeps approval on hold; final approval requires an authorized reviewer.<\/p>\n<form id=\"ky-sample-worksheet\" autocomplete=\"off\" action=\"\">\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>1*. The exact model and suffix match the quotation, sample label and datasheet.<\/legend>\n<p><label for=\"ky-result-0\">Ergebnis<\/label><select id=\"ky-result-0\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-0\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-0\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>2*. The rated DC voltage, current, pole arrangement and connection method meet the engineering specification.<\/legend>\n<p><label for=\"ky-result-1\">Ergebnis<\/label><select id=\"ky-result-1\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-1\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-1\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>3. Dimensions, mounting and terminal access fit the intended panel.<\/legend>\n<p><label for=\"ky-result-2\">Ergebnis<\/label><select id=\"ky-result-2\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-2\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-2\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>4. The latest datasheet, drawing and installation instructions are available and consistent.<\/legend>\n<p><label for=\"ky-result-3\">Ergebnis<\/label><select id=\"ky-result-3\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-3\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-3\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>5*. Any required certification can be verified for the exact offered model and rating.<\/legend>\n<p><label for=\"ky-result-4\">Ergebnis<\/label><select id=\"ky-result-4\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-4\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-4\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>6*. Required engineering tests or acceptable test evidence have been completed and reviewed.<\/legend>\n<p><label for=\"ky-result-5\">Ergebnis<\/label><select id=\"ky-result-5\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-5\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-5\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>7. Markings, accessories, packaging and OEM artwork match the agreed requirements.<\/legend>\n<p><label for=\"ky-result-6\">Ergebnis<\/label><select id=\"ky-result-6\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-6\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-6\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>8. The production quotation covers the same configuration as the approved sample.<\/legend>\n<p><label for=\"ky-result-7\">Ergebnis<\/label><select id=\"ky-result-7\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-7\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-7\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>9. Batch identification and incoming inspection requirements are defined.<\/legend>\n<p><label for=\"ky-result-8\">Ergebnis<\/label><select id=\"ky-result-8\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-8\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-8\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<fieldset style=\"padding:16px;margin:16px 0;border:1px solid #cbd5e1;border-radius:8px;min-width:0\">\n<legend>10. The supplier has agreed to notify the buyer before relevant product or process changes.<\/legend>\n<p><label for=\"ky-result-9\">Ergebnis<\/label><select id=\"ky-result-9\" style=\"width:100%;max-width:100%\"><option value=\"\">Not reviewed<\/option><option value=\"yes\">Yes \u2014 evidence reviewed<\/option><option value=\"no\">No \u2014 unresolved<\/option><option value=\"na\">Not applicable \u2014 explain below<\/option><\/select><label for=\"ky-note-9\">Evidence reference, open issue or N\/A reason<\/label><textarea id=\"ky-note-9\" rows=\"2\" style=\"width:100%;max-width:100%;box-sizing:border-box\"><\/textarea><\/fieldset>\n<p><button type=\"reset\">Reset worksheet<\/button><input type=\"hidden\" name=\"trp-form-language\" value=\"de\"\/><\/form>\n<h3>How to record the decision<\/h3>\n<p><strong>On hold:<\/strong> Any applicable requirement remains unanswered, unsupported or inconsistent. Record the missing evidence, responsible person and due date. Do not offset an unresolved requirement with positive answers elsewhere.<\/p>\n<p><strong>Approved:<\/strong> The authorized reviewer has accepted all applicable requirements and identified the exact approved configuration and document revisions. For a non-applicable item, record the reason and reviewer acceptance instead of treating it as a pass.<\/p>\n<p><strong>Rejected:<\/strong> Record the failed requirement and whether a corrected submission or replacement sample will be considered.<\/p>\n<h3>Copy this sample inspection and approval record<\/h3>\n<pre style=\"white-space:pre-wrap;overflow-wrap:anywhere\"><code>Sample reference \/ receipt date:\nSupplier \/ exact model and suffix:\nSample quantity \/ batch identification:\nIntended application \/ project:\nDatasheet, drawing and instruction revisions:\nInspection photographs and file references:\nRequirement \/ evidence reference \/ result:\nOpen issue \/ responsible person \/ due date:\nEngineering review and test report references:\nCertification verification reference, scope and date:\nNon-applicable items and accepted reasons:\nFinal decision: ON HOLD \/ APPROVED \/ REJECTED\nApproved configuration and exclusions:\nReviewer \/ role \/ decision date:\nProduction order and change-control reference:<\/code><\/pre>\n<p><em>This checklist is a purchasing and documentation aid. It does not replace engineering assessment, required testing or applicable certification requirements.<\/em><\/p>\n<h3>Example: why a matching current rating is not enough<\/h3>\n<p><strong>Illustrative documentation example:<\/strong> The quotation names model A, but the sample label names model A-X and the supplied drawing only covers model A. Even if the current rating looks identical, record the discrepancy and keep the submission on hold. Request documents covering A-X and have the reviewer confirm the intended configuration before releasing the production order. This example is not a test result or a claim about any Kuangya model.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>How many samples should an OEM buyer request?<\/h3>\n<p>Base the quantity on the evaluation plan, the configurations being considered and whether any tests consume or damage samples. Agree the quantity with your engineering or testing team before ordering.<\/p>\n<h3>Can one approved sample cover the whole product series?<\/h3>\n<p>Do not assume that it does. Record exactly which models and configurations the approval covers, and require an engineering basis for extending it to other ratings or accessories.<\/p>\n<h3>What should I send Kuangya for a sample enquiry?<\/h3>\n<p>Send the application brief and completed request template, including unresolved engineering questions. Review the <a href=\"https:\/\/cnkuangya.com\/de\/dc-mcb\/\">DC MCB range<\/a> and email <a href=\"mailto:info@cnkuangya.com\">info@cnkuangya.com<\/a> with the subject <strong>DC circuit breaker sample enquiry<\/strong>. Ask for confirmation of the exact model, supporting documents, sample cost and delivery time before ordering.<\/p>","protected":false},"excerpt":{"rendered":"<p>A practical sample approval workflow for OEM buyers: match the exact DC circuit breaker model to its documents, organize evaluation evidence, and define the production reference before ordering.<\/p>","protected":false},"author":4,"featured_media":3938,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55,35,45],"tags":[111,76,109,110],"class_list":["post-4487","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-circuit-breakers","category-blog","category-dc-protection-safety","tag-circuit-breaker-testing","tag-dc-circuit-breaker","tag-oem","tag-sample-approval"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/posts\/4487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/comments?post=4487"}],"version-history":[{"count":7,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/posts\/4487\/revisions"}],"predecessor-version":[{"id":4505,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/posts\/4487\/revisions\/4505"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/media\/3938"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/media?parent=4487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/categories?post=4487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/de\/wp-json\/wp\/v2\/tags?post=4487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}