{"id":972,"date":"2025-09-02T07:36:18","date_gmt":"2025-09-02T07:36:18","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=972"},"modified":"2025-09-14T06:39:16","modified_gmt":"2025-09-14T06:39:16","slug":"dc-spd-t1-t2-1500vdc","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/dc-spd-t1-t2-1500vdc\/","title":{"rendered":"KY-15T\/G1500 \u2014 T1+T2 DC Surge Protective Device (1500V)"},"content":{"rendered":"<section id=\"overview\">\n<h2>Overview<\/h2>\n<p>The <strong>1500v dc spd t1+t2<\/strong> KY-15T\/G1500 is a combined Type 1+2 surge protective device<br \/>\nfor <a href=\"\/pv-combiner-box\">PV combiner boxes<\/a>, inverter DC inputs, and DC feeders up to 1500VDC.<br \/>\nIt safely handles lightning current discharge while limiting residual voltage, ensuring reliable protection<br \/>\nfor photovoltaic systems. Fully compliant with<br \/>\n<a href=\"https:\/\/webstore.iec.ch\/publication\/26146\" target=\"_blank\" rel=\"noopener\">IEC 61643-31<\/a>, CE, UKCA, and RoHS standards.<\/p>\n<\/section>\n<section id=\"key-features\">\n<h2>Key Features<\/h2>\n<ul>\n<li>Combined <strong>1500v dc spd t1+t2<\/strong> protection for photovoltaic arrays and inverters.<\/li>\n<li>High discharge capacity and low residual voltage for utility and C&amp;I PV projects.<\/li>\n<li>Replaceable module design with clear status indicator.<\/li>\n<li>Remote alarm contacts reserved (NO\/NC, per datasheet).<\/li>\n<li>Compact DIN-rail design with flame-retardant housing (UL94-V0).<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h2>Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Type<\/th>\n<td>T1+T2<\/td>\n<\/tr>\n<tr>\n<th>System Voltage (U<sub>cpv<\/sub>)<\/th>\n<td>1500 V DC<\/td>\n<\/tr>\n<tr>\n<th>Nominal Discharge Current (I<sub>n<\/sub>)<\/th>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<th>Maximum Discharge Current (I<sub>max<\/sub>)<\/th>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<th>Impulse Current (I<sub>imp<\/sub>)<\/th>\n<td>6.25 kA<\/td>\n<\/tr>\n<tr>\n<th>Voltage Protection Level (U<sub>p<\/sub>)<\/th>\n<td>\u2264 5.5 kV<\/td>\n<\/tr>\n<tr>\n<th>Response Time (t<sub>a<\/sub>)<\/th>\n<td>&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<th>Admissible Short-Circuit Current (I<sub>scpv<\/sub>)<\/th>\n<td>10 kA<\/td>\n<\/tr>\n<tr>\n<th>Remote Alarm Contact<\/th>\n<td>220V, 0.5A, NO\/NC<\/td>\n<\/tr>\n<tr>\n<th>Standards<\/th>\n<td>IEC 61643-31, GB\/T 18802.31, CE, UKCA, RoHS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"diagram\">\n<h2>Wiring &amp; Dimension<\/h2>\n<figure>wiring:<\/figure>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-970\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Wiring-Diagram-300x231.png\" alt=\"Wiring diagram of KY T1+T2 DC SPD surge protective device for 1000V and 1500V photovoltaic systems\" width=\"491\" height=\"378\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Wiring-Diagram-300x231.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Wiring-Diagram.png 554w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><\/figure>\n<p>Dimension:<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-969\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension-300x149.png\" alt=\"Dimension drawing of KY T1+T2 DC surge protective device for PV combiner box and inverter protection\" width=\"483\" height=\"240\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension-300x149.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension-600x299.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/KY-15T-T1T2-Dimension.png 753w\" sizes=\"auto, (max-width: 483px) 100vw, 483px\" \/><\/figure>\n<\/section>\n<section id=\"applications\">\n<h2>Applications<\/h2>\n<ul>\n<li>Utility-scale PV plants and large solar farms requiring 1500V DC surge protection.<\/li>\n<li>Commercial and industrial PV rooftops with higher DC system voltage.<\/li>\n<li>Critical infrastructure PV installations exposed to frequent lightning surges.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h2>FAQs<\/h2>\n<h3>Q1. What is the role of a 1500v dc spd t1+t2 in PV systems?<\/h3>\n<p>It provides both lightning current (Type 1) and surge voltage (Type 2) protection, suitable for main DC entry points in 1500V PV plants.<\/p>\n<h3>Q2. Can the 1500v dc spd t1+t2 be installed in PV inverters?<\/h3>\n<p>Yes, KY-15T\/G1500 is designed for inverter DC inputs up to 1500V, preventing overvoltage and ensuring inverter safety.<\/p>\n<h3>Q3. How does KY-15T\/G1500 compare to 1000V SPD models?<\/h3>\n<p>It supports higher system voltage (1500V) and is ideal for large-scale PV plants where higher voltage strings are used.<\/p>\n<h3>Q4. Which standards cover KY-15T\/G1500?<\/h3>\n<p>IEC 61643-31, GB\/T 18802.31, CE, UKCA, and RoHS certifications are covered.<\/p>\n<\/section>\n<p><!-- ========================= JSON-LD: FAQ ONLY ========================= --><br \/>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the role of a 1500v dc spd t1+t2 in PV systems?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It provides both lightning current (Type 1) and surge voltage (Type 2) protection, suitable for main DC entry points in 1500V PV plants.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the 1500v dc spd t1+t2 be installed in PV inverters?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, KY-15T\/G1500 is designed for inverter DC inputs up to 1500V, preventing overvoltage and ensuring inverter safety.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does KY-15T\/G1500 compare to 1000V SPD models?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It supports higher system voltage (1500V) and is ideal for large-scale PV plants where higher voltage strings are used.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which standards cover KY-15T\/G1500?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"IEC 61643-31, GB\/T 18802.31, CE, UKCA, and RoHS certifications are covered.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<section id=\"cta\"><a class=\"btn\" href=\"\/contact-us\">Request a Quote for 1500v dc spd t1+t2<\/a><\/section>\n","protected":false},"excerpt":{"rendered":"<p>(1) The <strong data-start=\"401\" data-end=\"423\">1500v dc spd t1+t2<\/strong> KY-15T\/G1500 provides combined Type 1+2 surge protection for photovoltaic DC systems.<\/p>\n<p><br data-start=\"509\" data-end=\"512\" \/>(2) Designed for utility-scale PV plants, inverters, and combiner boxes, compliant with IEC 61643-31 and CE\/UKCA\/RoHS.<\/p>\n<p><br data-start=\"630\" data-end=\"633\" \/>(3) Features replaceable modules, remote alarm option, and shared wiring\/dimension diagrams for T1+T2 series.<\/p>","protected":false},"featured_media":1535,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[26],"product_tag":[],"class_list":{"0":"post-972","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-dc-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/972","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=972"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1535"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=972"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=972"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=972"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=972"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}