{"id":1573,"date":"2025-09-16T07:07:39","date_gmt":"2025-09-16T07:07:39","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1573"},"modified":"2025-09-16T09:54:32","modified_gmt":"2025-09-16T09:54:32","slug":"b-type-rccb-vkl11-b-b","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/b-type-rccb-vkl11-b-b\/","title":{"rendered":"RCCB VKL11 (B\/B+) - \u0642\u0627\u0637\u0639 \u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a"},"content":{"rendered":"<div class=\"product-description\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>VKL11 (B\/B+) is a <strong>b type rccb<\/strong> designed to disconnect the circuit when residual current exceeds<br \/>\nthe threshold, helping prevent electric shock and fire hazards due to insulation faults. The Type B\/B+ variants<br \/>\nare suitable for leakage containing smooth DC and higher-frequency components often present with frequency<br \/>\nconverters, inverters, PV\/EV equipment, and VFD-driven motors. Pole options include 2P for single-phase and<br \/>\n4P for three-phase systems.<\/p>\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li><strong>\u0627\u0644\u0623\u0639\u0645\u062f\u0629:<\/strong> 2 \u0641-2\/\u0641-4<\/li>\n<li><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u062f\u0631 (\u0641\u064a):<\/strong> 16, 25, 32, 40, 63, 80, 100 A<\/li>\n<li><strong>\u0627\u0644\u062d\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (I\u0394n):<\/strong> 10 \/ 30 \/ 100 \/ 100 \/ 300 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/li>\n<li><strong>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 (Ue):<\/strong> 240 \u0641\u0648\u0644\u062a ~ (2 \u0641\u0648\u0644\u062a) \/ 415 \u0641\u0648\u0644\u062a ~ (4 \u0641\u0648\u0644\u062a); <strong>\u064a\u0648 \u0622\u064a<\/strong> 500 V; <strong>\u0627\u0644\u062a\u0631\u062f\u062f:<\/strong> 50\/60 \u0647\u0631\u062a\u0632<\/li>\n<li><strong>\u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0648\u0627\u0644\u0643\u0633\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a (I\u0394m):<\/strong> 500 \/ 630 \/ 800 \/ 1000 \u0623\u0645\u0628\u064a\u0631 (\u0644\u0643\u0644 \u0645\u062c\u0645\u0648\u0639\u0629 \u0641\u064a \u0627\u0644\u0645\u062c\u0645\u0648\u0639\u0629)<\/li>\n<li><strong>\u062f\u0627\u0626\u0631\u0629 \u0642\u0635\u0631 \u0645\u0634\u0631\u0648\u0637\u0629 (Inc = I\u0394c):<\/strong> 6000 A \/ 10000 A (with upstream SCPD coordination)<\/li>\n<li><strong>\u0627\u0644\u0635\u0645\u0648\u062f \u0627\u0644\u062f\u0627\u0641\u0639 (Uimp):<\/strong> 4 kV \/ 6 kV (by variant)<\/li>\n<li><strong>\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629:<\/strong> IP20; DIN rail EN 60715 (35 mm) mounting<\/li>\n<\/ul>\n<h2>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0637\u0631\u0627\u0632<\/th>\n<td>VKL11 (B\/B+)<\/td>\n<\/tr>\n<tr>\n<td>\u0642\u064a\u0627\u0633\u064a<\/td>\n<td>IEC\/EN 61008-1<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/td>\n<td>2 \u0641\u060c 4 \u0641\u060c 2 \u0641\u060c 4 \u0641<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u062f\u0631 (\u0641\u064a)<\/td>\n<td>16A\u060c 25A\u060c 32A\u060c 40A\u060c 63A\u060c 80A\u060c 100A\u060c 100A<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062d\u0633\u0627\u0633\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629 (I\u0394n)<\/td>\n<td>10 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631\u060c 30 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631\u060c 100 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631\u060c 300 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0645\u0642\u0646\u0646 (Ue)<\/td>\n<td>2 \u0641\u0648\u0644\u062a: 240 \u0641\u0648\u0644\u062a~\u061b 4 \u0641\u0648\u0644\u062a: 415 \u0641\u0648\u0644\u062a~<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u0639\u0632\u0644 (Ui)<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u0642\u062f\u0631<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0635\u0646\u064a\u0639 \u0648\u0627\u0644\u0643\u0633\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a (I\u0394m)<\/td>\n<td>500 A (In 16\u201340 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0627\u0626\u0631\u0629 \u0642\u0635\u0631 \u0645\u0634\u0631\u0648\u0637\u0629 (Inc = I\u0394c)<\/td>\n<td>6000 A; 10000 A<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0635\u0645\u0648\u062f \u0627\u0644\u062f\u0627\u0641\u0639 (Uimp)<\/td>\n<td>4 kV \/ 6 kV (per variant)<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0637\u0631\u0641\u064a\u0629<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629<\/td>\n<td>\u221225 \u00b0C to +55 \u00b0C (daily avg \u2264 35 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u062e\u0632\u064a\u0646<\/td>\n<td>-40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0625\u0644\u0649 +70 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>Terminal connection<\/td>\n<td>\u0643\u0627\u0628\u0644 \/ \u0642\u0636\u064a\u0628 \u0646\u0627\u0642\u0644 \u0645\u0646 \u0646\u0648\u0639 \u062f\u0628\u0648\u0633<\/td>\n<\/tr>\n<tr>\n<td>Terminal size (cable)<\/td>\n<td>25-35 \u0645\u0645\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Terminal size (busbar)<\/td>\n<td>10\/16 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>\u0639\u0632\u0645 \u062f\u0648\u0631\u0627\u0646 \u0627\u0644\u0634\u062f<\/td>\n<td>2.5 \u0646\u064a\u0648\u062a\u0646-\u0645\u062a\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td>DIN rail EN 60715 (35 mm)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0627\u062a\u0635\u0627\u0644<\/td>\n<td>Top and bottom<\/td>\n<\/tr>\n<tr>\n<td>Waveform classes<\/td>\n<td>Type B \/ B+ (DC-capable); AC, A (where applicable by variant)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>PV arrays, EV charging, variable-frequency drives, UPS\/inverters requiring <strong>b type rccb<\/strong><\/li>\n<li>Three-phase boards (4P) and single-phase boards (2P) with leakage containing DC or high-frequency components<\/li>\n<li>Installations coordinated with upstream SCPD for 6\/10 kA conditional short-circuit ratings<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"\/images\/rccb-vkl11-b.jpg\" alt=\"b type rccb VKL11 (B\/B+) Kuangya 2P\/4P 16\u2013100A 10\/30\/100\/300 mA\" \/><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"334\" data-end=\"475\">\n<p data-start=\"336\" data-end=\"475\">The Kuangya VKL11 <strong data-start=\"354\" data-end=\"369\">b type rccb<\/strong> provides residual-current protection with Type B\/B+ detection suitable for AC and DC leakage conditions<\/p>\n<\/li>\n<li data-start=\"476\" data-end=\"570\">\n<p data-start=\"478\" data-end=\"570\">2P \/ 4P; In 16\u2013100 A; I\u0394n 10\/30\/100\/300 mA; Ue 240 V (2P) \/ 415 V (4P); Ui 500 V; 50\/60 Hz<\/p>\n<\/li>\n<li data-start=\"571\" data-end=\"673\">\n<p data-start=\"573\" data-end=\"673\">Uimp 4\/6 kV (per variant); Inc = I\u0394c 6\/10 kA (with upstream SCPD); IP20 terminals; DIN-rail EN 60715<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":["post-1573","product","type-product","status-publish","product_cat-rccb","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1573"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1573"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1573"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1573"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1573"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}