{"id":1563,"date":"2025-09-15T10:15:21","date_gmt":"2025-09-15T10:15:21","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1563"},"modified":"2025-09-22T09:01:57","modified_gmt":"2025-09-22T09:01:57","slug":"rccb-2-pole-vfl002","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/rccb-2-pole-vfl002\/","title":{"rendered":"RCCB VFL002 - \u0642\u0627\u0637\u0639 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a 2\/4 \u0623\u0642\u0637\u0627\u0628"},"content":{"rendered":"<div class=\"product-description\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>The Kuangya VFL002 is an <strong>\u0639\u0645\u0648\u062f rccb 2<\/strong> (also available as 4 pole) residual current device engineered to<br \/>\nprotect people and installations from electric shock and fire risk due to earth-leakage faults. It offers AC, A, and<br \/>\nhigh-immunity ASi detection classes, making it suitable for residential housing, commercial buildings, and light<br \/>\nindustrial facilities. Selection covers rated currents from 16 A to 100 A and sensitivities from 10 mA to 300 mA.<\/p>\n<h2>Detection classes &amp; tripping<\/h2>\n<ul>\n<li><strong>AC class<\/strong> \u2014 trips for sinusoidal AC residual currents applied slowly or suddenly.<\/li>\n<li><strong>A class<\/strong> \u2014 AC plus pulsating DC residual currents.<\/li>\n<li><strong>ASi type<\/strong> \u2014 high-immunity A type (G\/KV + Si behavior); filters transients\/harmonics to reduce nuisance tripping.<\/li>\n<\/ul>\n<ul>\n<li><strong>Break time under I\u0394n (Normal):<\/strong> \u2264 100 ms<\/li>\n<li><strong>Short time delay:<\/strong> 10\u2013300 ms (ASi, G, KV types)<\/li>\n<li><strong>Selective S type:<\/strong> 150\u2013500 ms<\/li>\n<\/ul>\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li>Configurations: <strong>2 \u0641-2\/\u0641-4<\/strong> with top or bottom supply, any mounting position<\/li>\n<li><strong>Rated current In:<\/strong> 16, 25, 32, 40, 63, 80, 100 A<\/li>\n<li><strong>Rated sensitivity I\u0394n:<\/strong> 10 mA (2P\/4P 16\u201340 A), 30 mA, 100 mA, 300 mA<\/li>\n<li><strong>Rated voltage Ue:<\/strong> 2P: 240 V~; 4P: 415 V~ \u00a0 | \u00a0 <strong>Ui:<\/strong> 500 V \u00a0 | \u00a0 <strong>fn:<\/strong> 50\/60 \u0647\u0631\u062a\u0632<\/li>\n<li><strong>Rated residual making &amp; breaking (I\u0394m):<\/strong> 500 A (In 16\u201340 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)<\/li>\n<li><strong>Inc = I\u0394c (conditional short-circuit):<\/strong> 6 kA or 10 kA (with upstream SCPD coordination)<\/li>\n<li><strong>Impulse withstand Uimp:<\/strong> 6 kV (1.2\/50 \u03bcs); <strong>Dielectric test:<\/strong> 2.5 kV \/ 1 min<\/li>\n<li><strong>Terminal protection:<\/strong> IP20; fault current indicator provided<\/li>\n<li><strong>Ambient:<\/strong> \u221225 \u00b0C \u2026 +55 \u00b0C (daily average \u2264 35 \u00b0C); <strong>Storage:<\/strong> \u221240 \u00b0C \u2026 +70 \u00b0C<\/li>\n<li><strong>Standards\/Approvals:<\/strong> IEC\/EN 61008-1; NF, ISI, UKCA, CE<\/li>\n<\/ul>\n<h2>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h2>\n<table class=\"tech-table\">\n<tbody>\n<tr>\n<th>\u0642\u064a\u0627\u0633\u064a<\/th>\n<th>IEC\/EN 61008-1<\/th>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0637\u0631\u0627\u0632<\/td>\n<td>VFL002<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/td>\n<td>2P, 4P<\/td>\n<\/tr>\n<tr>\n<td>Rated current (In)<\/td>\n<td>16A, 25A, 32A, 40A, 63A, 80A, 100A<\/td>\n<\/tr>\n<tr>\n<td>Rated sensitivity (I\u0394n)<\/td>\n<td>10 mA (16\u201340 A), 30 mA, 100 mA, 300 mA<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage (Ue)<\/td>\n<td>2P: 240 V~; 4P: 415 V~<\/td>\n<\/tr>\n<tr>\n<td>Insulation voltage (Ui)<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>Rated frequency<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>Rated residual making &amp; breaking (I\u0394m)<\/td>\n<td>500 A (In = 16\u201340 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)<\/td>\n<\/tr>\n<tr>\n<td>Conditional short-circuit (Inc = I\u0394c)<\/td>\n<td>6000 A, 10000 A<\/td>\n<\/tr>\n<tr>\n<td>Waveform sensitivity<\/td>\n<td>AC, A, ASi<\/td>\n<\/tr>\n<tr>\n<td>Tripping time classes<\/td>\n<td>Instantaneous \/ Short time delay (10\u2013300 ms) \/ Selective S (150\u2013500 ms)<\/td>\n<\/tr>\n<tr>\n<td>Break time under I\u0394n (Normal)<\/td>\n<td>\u2264 100 ms<\/td>\n<\/tr>\n<tr>\n<td>Impulse withstand (Uimp)<\/td>\n<td>6 kV<\/td>\n<\/tr>\n<tr>\n<td>Dielectric test voltage<\/td>\n<td>2.5 kV (1 min at power frequency)<\/td>\n<\/tr>\n<tr>\n<td>Pollution degree<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Electrical life<\/td>\n<td>\u2265 2000 operations<\/td>\n<\/tr>\n<tr>\n<td>Mechanical life<\/td>\n<td>\u2265 2000 operations<\/td>\n<\/tr>\n<tr>\n<td>Fault current indicator<\/td>\n<td>\u0646\u0639\u0645<\/td>\n<\/tr>\n<tr>\n<td>Terminal protection degree<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature (avg \u2264 35 \u00b0C)<\/td>\n<td>\u221225 \u00b0C to +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>\u221240 \u00b0C to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Terminal connection<\/td>\n<td>Cable \/ Pin-type busbar<\/td>\n<\/tr>\n<tr>\n<td>Terminal size (cable, top\/bottom)<\/td>\n<td>25\u201335 mm\u00b2; 18\u20133 \/ 18\u20132 AWG (per size class)<\/td>\n<\/tr>\n<tr>\n<td>Terminal size (busbar, top\/bottom)<\/td>\n<td>10\/16 mm\u00b2; 18\u20138 \/ 18\u20135 AWG<\/td>\n<\/tr>\n<tr>\n<td>\u0639\u0632\u0645 \u062f\u0648\u0631\u0627\u0646 \u0627\u0644\u0634\u062f<\/td>\n<td>2.5 N\u00b7m (\u2248 22 in-lbs)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td>DIN rail EN 60715 (35 mm), fast clip<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td>From top and bottom<\/td>\n<\/tr>\n<tr>\n<td>Approvals<\/td>\n<td>NF, ISI, UKCA, CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Single-phase boards requiring an <strong>\u0639\u0645\u0648\u062f rccb 2<\/strong> device at 240 V~<\/li>\n<li>Three-phase distribution using 4P at 415 V~ with coordinated upstream SCPD<\/li>\n<li>Loads with electronics and frequent transients \u2014 use ASi high-immunity version<\/li>\n<\/ul>\n<h2>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a<\/h2>\n<p>Conforms to <strong>IEC\/EN 61008-1<\/strong>; certified <strong>NF, ISI, UKCA, CE<\/strong>.<\/p>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<details>\n<summary>When do I choose 2P vs 4P?<\/summary>\n<p>Use 2P for single-phase 240 V~ systems and 4P for three-phase 415 V~ systems.<\/p>\n<\/details>\n<details>\n<summary>What sensitivity should I select?<\/summary>\n<p>10\/30 mA for additional personal protection; 100\/300 mA for fire protection and selectivity.<\/p>\n<\/details>\n<details>\n<summary>How to coordinate conditional short-circuit rating?<\/summary>\n<p>Use an upstream breaker\/fuse so the installation respects <strong>Inc = I\u0394c<\/strong> (6 kA \/ 10 kA) under fault conditions.<\/p>\n<\/details>\n<p><img decoding=\"async\" src=\"\/images\/rccb-vfl002.jpg\" alt=\"rccb 2 pole VFL002 Kuangya, 2P\/4P 16\u2013100A 10\/30\/100\/300 mA\" \/><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul data-start=\"303\" data-end=\"585\">\n<li data-start=\"303\" data-end=\"413\">\n<p data-start=\"305\" data-end=\"413\"><strong data-start=\"305\" data-end=\"320\">\u0639\u0645\u0648\u062f rccb 2<\/strong> for reliable earth-leakage protection in single-phase and three-phase boards (2P\/4P range)<\/p>\n<\/li>\n<li data-start=\"414\" data-end=\"513\">\n<p data-start=\"416\" data-end=\"513\">In: 16\u2013100A; I\u0394n: 10\/30\/100\/300 mA; Ue: 240 V (2P) \/ 415 V (4P); Inc=I\u0394c up to 10 kA; Uimp 6 kV<\/p>\n<\/li>\n<li data-start=\"514\" data-end=\"585\">\n<p data-start=\"516\" data-end=\"585\">AC \/ A \/ ASi options; IEC\/EN 61008-1 with NF, ISI, UKCA, CE approvals<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1797,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-1563","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1563","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1563"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1797"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1563"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1563"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1563"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1563"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}