{"id":1560,"date":"2025-09-15T07:47:24","date_gmt":"2025-09-15T07:47:24","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1560"},"modified":"2025-09-27T14:29:21","modified_gmt":"2025-09-27T14:29:21","slug":"hrd7-3-phase-rcbo","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/hrd7-3-phase-rcbo\/","title":{"rendered":"HRD7 RCBO \u2014 1P+N \/ 3P+N, 6\u201332A (Magnetic \/ Electronic)"},"content":{"rendered":"<p><!-- Ensure the Focus KW appears right at the beginning --><\/p>\n<p><strong>3 phase rcbo<\/strong> HRD7 integrates residual-current and overcurrent protection in compact 1P+N and 3P+N formats, covering 6\u201332 A at 240\/415 V, 50\/60 Hz. It is available in both magnetic and electronic versions to match different coordination strategies and installation preferences.<\/p>\n<section id=\"overview\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>HRD7 is designed for residential, commercial, and light-industrial boards where<br \/>\ncombined RCD + MCB functionality is required on single-phase and three-phase circuits.<br \/>\nWith Type AC \/ Type A residual protection and four standard sensitivities<br \/>\n(10 \/ 30 \/ 100 \/ 300 mA), HRD7 achieves reliable touch protection and discrimination.<br \/>\nThe range supports 1P+N and 3P+N configurations with a 6 kA breaking capacity<br \/>\nto address common fault levels on 240 V \/ 415 V grids. This three phase rcbo option<br \/>\nsupports coordinated selectivity on three-phase boards.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li>Poles: <strong>1P+N<\/strong> (single-pole + neutral) and <strong>3P+N<\/strong><\/li>\n<li>Rated current (In): <strong>6\u201332 A<\/strong><\/li>\n<li>Rated voltage (Ue): <strong>AC 240 V<\/strong> \/ <strong>AC 415 V<\/strong>, <strong>50\/60 \u0647\u0631\u062a\u0632<\/strong><\/li>\n<li>Residual current type: <strong>Type AC \/ Type A<\/strong><\/li>\n<li>Sensitivity (I\u0394n): <strong>10 \/ 30 \/ 100 \/ 100 \/ 300 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/strong><\/li>\n<li>Breaking capacity (Icn): <strong>6 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/strong><\/li>\n<li>Trip unit: <strong>Magnetic<\/strong> \u0623\u0648 <strong>Electronic<\/strong><\/li>\n<li>Endurance: <strong>Mechanical 12,000 cycles<\/strong>; <strong>Electrical 6,000 cycles<\/strong><\/li>\n<li>DIN-rail mounting; front wiring; front test button (T)<\/li>\n<li>Compliance &amp; certification: <strong>IEC\/EN 61009-1<\/strong>; <strong>SEMKO, UKCA, CE, SAA<\/strong><\/li>\n<\/ul>\n<\/section>\n<section id=\"technical-data\">\n<h2>3 Phase RCBO Technical Data \u2014 HRD7<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>HRD7 (1P+N)<\/th>\n<th>HRD7 (3P+N)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/td>\n<td>1P+N<\/td>\n<td>3P+N<\/td>\n<\/tr>\n<tr>\n<td>Rated current (In)<\/td>\n<td>6\u201332 A<\/td>\n<td>6\u201332 A<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage (Ue)<\/td>\n<td>AC 240 V<\/td>\n<td>AC 415 V<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td colspan=\"2\">50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a<\/td>\n<td colspan=\"2\">Type AC \/ Type A<\/td>\n<\/tr>\n<tr>\n<td>Rated residual current (I\u0394n)<\/td>\n<td colspan=\"2\">10 \/ 30 \/ 100 \/ 100 \/ 300 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<td>Breaking capacity (Icn)<\/td>\n<td colspan=\"2\">6 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<td>Trip unit<\/td>\n<td colspan=\"2\">Magnetic \/ Electronic<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u062a\u062d\u0645\u0644<\/td>\n<td colspan=\"2\">Mechanical 12,000 cycles; Electrical 6,000 cycles<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td colspan=\"2\">DIN-rail; front wiring; test button (T)<\/td>\n<\/tr>\n<tr>\n<td>Recommended use<\/td>\n<td colspan=\"2\">Residential, commercial &amp; light-industrial branches and feeders up to 32 A<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/td>\n<td colspan=\"2\">IEC\/EN 61009-1<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a<\/td>\n<td colspan=\"2\">SEMKO, UKCA, CE, SAA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"applications\">\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Apartment &amp; commercial boards requiring combined residual and overcurrent protection<\/li>\n<li>Three-phase panels needing 3P+N with coordinated selectivity<\/li>\n<li>Auxiliary\/feeder circuits up to 32 A on 240\/415 V systems<\/li>\n<\/ul>\n<\/section>\n<section id=\"media\">\n<h2>Downloads &amp; Images<\/h2>\n<p><img decoding=\"async\" src=\"REPLACE-WITH-YOUR-IMAGE.jpg\" alt=\"3 phase rcbo HRD7 1P+N \/ 3P+N, 6\u201332A, Type AC\/A, I\u0394n 10\/30\/100\/300 mA, Icn 6 kA, 240\/415 V\" \/><\/p>\n<\/section>\n<section id=\"certs\">\n<h2>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644<\/h2>\n<p>Conforms to <strong>IEC\/EN 61009-1<\/strong>. Certified by <strong>SEMKO, UKCA, CE, SAA<\/strong>.<br \/>\nAlways verify discrimination and coordination with upstream devices and local codes.<\/p>\n<\/section>\n<section id=\"faq\">\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<details>\n<summary>When should I choose HRD7 magnetic vs electronic?<\/summary>\n<div>\n<p>Magnetic versions suit simpler coordination and rugged operation; electronic versions may offer finer residual detection behavior and stable performance across wider conditions. Select based on coordination studies and installation specs.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>What I\u0394n should be used upstream vs downstream?<\/summary>\n<div>\n<p>Downstream final circuits commonly use 30 mA. Upstream feeders often adopt 100\u2013300 mA to maintain selectivity. Follow local codes and discrimination rules.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>Does HRD7 support both single-phase and three-phase boards?<\/summary>\n<div>\n<p>Yes. Use 1P+N for single-phase branches and 3P+N for three-phase circuits that require neutral protection.<\/p>\n<\/div>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"420\" data-end=\"528\">\n<ul>\n<li data-start=\"373\" data-end=\"481\">\n<p data-start=\"375\" data-end=\"481\"><strong data-start=\"375\" data-end=\"391\">3 phase rcbo<\/strong> HRD7 with <strong data-start=\"402\" data-end=\"417\">1P+N \/ 3P+N<\/strong> options for single- &amp; three-phase distribution, <strong data-start=\"466\" data-end=\"478\">In 6\u201332A<\/strong>.<\/p>\n<\/li>\n<li data-start=\"482\" data-end=\"583\">\n<p data-start=\"484\" data-end=\"583\"><strong data-start=\"484\" data-end=\"504\">Type AC \/ Type A<\/strong>, <strong data-start=\"506\" data-end=\"536\">I\u0394n 10 \/ 30 \/ 100 \/ 300 mA<\/strong>; <strong data-start=\"538\" data-end=\"550\">Icn 6 kA<\/strong>, <strong data-start=\"552\" data-end=\"570\">Ue 240 \/ 415 V<\/strong>, 50\/60 Hz.<\/p>\n<\/li>\n<li data-start=\"584\" data-end=\"729\">\n<p data-start=\"586\" data-end=\"729\"><strong data-start=\"586\" data-end=\"611\">Magnetic \/ Electronic<\/strong> versions; endurance <strong data-start=\"632\" data-end=\"679\">Mechanical 12,000 \/ Electrical 6,000 cycles<\/strong>; <strong data-start=\"681\" data-end=\"699\">IEC\/EN 61009-1<\/strong>, <strong data-start=\"701\" data-end=\"728\">SEMKO \/ UKCA \/ CE \/ SAA<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>","protected":false},"featured_media":1853,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[36],"product_tag":[],"class_list":{"0":"post-1560","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rcbo","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1560"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1853"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1560"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1560"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1560"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}