{"id":1559,"date":"2025-09-15T07:33:58","date_gmt":"2025-09-15T07:33:58","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1559"},"modified":"2025-09-22T07:59:58","modified_gmt":"2025-09-22T07:59:58","slug":"vrl11-rcbo-single-pole","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/vrl11-rcbo-single-pole\/","title":{"rendered":"VRL11 RCBO \u2014 Single-Pole + Neutral (1P+N) 5\u201340A"},"content":{"rendered":"<p><!-- Ensure the Focus KW appears at the very beginning --><\/p>\n<p><strong>rcbo single pole<\/strong> VRL11 integrates residual-current and overcurrent protection in a compact 1P+N footprint for single-phase boards, covering 5\u201340 A with Type AC\/A residual protection and B\/C tripping curves.<\/p>\n<section id=\"overview\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>VRL11 is designed for residential and commercial distribution branches where reliable<br \/>\nRCD + MCB functionality is required in minimal space. It supports 240 V and 120 V grids<br \/>\nwith high breaking capacities (10 kA @ 240 V; 15 kA @ 120 V), multiple residual<br \/>\nsensitivities from 6 mA to 300 mA, and curve B\/C options to coordinate with upstream devices.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li>\u0639\u0627\u0645\u0644 \u0627\u0644\u0634\u0643\u0644: <strong>1P+N<\/strong> (single-pole + neutral), modular DIN-rail<\/li>\n<li>Rated current (In): <strong>5\u201340 A<\/strong><\/li>\n<li>Rated voltage (Ue): <strong>AC 240 V<\/strong> \/ <strong>AC 120 V<\/strong>, 50\/60 Hz<\/li>\n<li>Residual current type: <strong>Type AC \/ Type A<\/strong><\/li>\n<li>Sensitivity (I\u0394n): <strong>6 \/ 10 \/ 30 \/ 100 \/ 300 mA<\/strong><\/li>\n<li>Tripping curves: <strong>B (3\u20135\u00d7In)<\/strong>, <strong>C (5\u201310\u00d7In)<\/strong><\/li>\n<li>Breaking capacity (Icn): <strong>10 kA @ 240 V<\/strong>; <strong>15 kA @ 120 V<\/strong><\/li>\n<li>Front test button (T); front wiring; compact installation depth<\/li>\n<li>Compliance &amp; certification: <strong>IEC\/EN 61009-1<\/strong>; <strong>SEMKO, UKCA, CE, SAA<\/strong><\/li>\n<\/ul>\n<\/section>\n<section id=\"technical-data\">\n<h2>RCBO Single Pole Technical Data \u2014 VRL11<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>VRL11<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/td>\n<td>1P+N (single-pole + neutral)<\/td>\n<\/tr>\n<tr>\n<td>Rated current (In)<\/td>\n<td>5\u201340 A<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage (Ue)<\/td>\n<td>AC 240 V \/ AC 120 V<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a<\/td>\n<td>Type AC \/ Type A<\/td>\n<\/tr>\n<tr>\n<td>Rated residual current (I\u0394n)<\/td>\n<td>6 \/ 10 \/ 30 \/ 100 \/ 300 mA<\/td>\n<\/tr>\n<tr>\n<td>MCB tripping curve<\/td>\n<td>B: 3\u20135 \u00d7 In; C: 5\u201310 \u00d7 In<\/td>\n<\/tr>\n<tr>\n<td>Breaking capacity (Icn)<\/td>\n<td>10 kA @ 240 V; 15 kA @ 120 V<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td>DIN-rail; front wiring; test button (T)<\/td>\n<\/tr>\n<tr>\n<td>Recommended use<\/td>\n<td>Residential &amp; commercial lighting\/socket branches up to 40 A<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/td>\n<td>IEC\/EN 61009-1<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a<\/td>\n<td>SEMKO, UKCA, CE, SAA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"applications\">\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Apartments &amp; houses: lighting and socket circuits (\u2264 40 A)<\/li>\n<li>Commercial offices &amp; retail: small-load branches<\/li>\n<li>Public facilities: admin rooms, classrooms, auxiliary circuits<\/li>\n<\/ul>\n<\/section>\n<section id=\"media\">\n<h2>Downloads &amp; Images<\/h2>\n<p><img decoding=\"async\" src=\"REPLACE-WITH-YOUR-IMAGE.jpg\" alt=\"rcbo single pole VRL11 1P+N, 5\u201340A, Type AC\/A, I\u0394n 6\/10\/30\/100\/300 mA, Icn 10 kA @240 V \/ 15 kA @120 V\" \/><\/p>\n<\/section>\n<section id=\"certs\">\n<h2>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644<\/h2>\n<p>Conforms to <strong>IEC\/EN 61009-1<\/strong>. Certified by <strong>SEMKO, UKCA, CE, SAA<\/strong>.<br \/>\nAlways coordinate with upstream devices and follow local codes for selectivity and fault levels.<\/p>\n<\/section>\n<section id=\"faq\">\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<details>\n<summary>What distinguishes VRL11 from other 1P+N RCBOs?<\/summary>\n<div>\n<p>VRL11 targets 5\u201340 A single-phase circuits on both 240 V and 120 V grids with high Icn (10 kA \/ 15 kA), Type AC\/A residual protection and curve B\/C options.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>Which sensitivity (I\u0394n) is typical for sockets and lighting?<\/summary>\n<div>\n<p>30 mA is most common; 6\u201310 mA for higher touch-safety; 100\u2013300 mA per coordination and code requirements.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>How do I choose between curve B and curve C?<\/summary>\n<div>\n<p>Use B (3\u20135\u00d7In) for resistive\/lightly inductive loads; use C (5\u201310\u00d7In) for higher inrush (motors, transformers). Verify discrimination with upstream protection.<\/p>\n<\/div>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"391\" data-end=\"492\">\n<p data-start=\"393\" data-end=\"492\"><strong data-start=\"393\" data-end=\"420\">rcbo single pole (1P+N)<\/strong> modular RCBO for single-phase branches, <strong data-start=\"461\" data-end=\"473\">In 5\u201340A<\/strong>, curves <strong data-start=\"482\" data-end=\"489\">\u0628\/\u062c<\/strong>.<\/p>\n<\/li>\n<li data-start=\"493\" data-end=\"607\">\n<p data-start=\"495\" data-end=\"607\"><strong data-start=\"495\" data-end=\"515\">Type AC \/ Type A<\/strong>, sensitivities <strong data-start=\"531\" data-end=\"565\">I\u0394n 6 \/ 10 \/ 30 \/ 100 \/ 300 mA<\/strong>; <strong data-start=\"567\" data-end=\"604\">Icn 10 kA @ 240 V \/ 15 kA @ 120 V<\/strong>.<\/p>\n<\/li>\n<li data-start=\"608\" data-end=\"678\">\n<p data-start=\"610\" data-end=\"678\"><strong data-start=\"610\" data-end=\"628\">IEC\/EN 61009-1<\/strong> compliant; certified <strong data-start=\"650\" data-end=\"677\">SEMKO \/ UKCA \/ CE \/ SAA<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1794,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[36],"product_tag":[],"class_list":{"0":"post-1559","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rcbo","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1559","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1559"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1794"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1559"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1559"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1559"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1559"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}