{"id":1555,"date":"2025-09-15T07:16:19","date_gmt":"2025-09-15T07:16:19","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1555"},"modified":"2025-09-22T07:38:33","modified_gmt":"2025-09-22T07:38:33","slug":"vk007le-rcbo-breaker","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/vk007le-rcbo-breaker\/","title":{"rendered":"VK007LE RCBO \u2014 1P+N \/ 2P \/ 3P \/ 3P+N \/ 4P, 6\u201363A"},"content":{"rendered":"<p><!-- \u5185\u5bb9\u5f00\u5934\u52a1\u5fc5\u542b Focus KW --><\/p>\n<p><strong>rcbo breaker<\/strong> VK007LE is a versatile multi-pole RCBO covering single- and three-phase applications with 1P+N, 2P, 3P, 3P+N and 4P options. It integrates residual-current and overcurrent protection with a wide current range (6\u201363 A), Type AC\/A residual modes, and multiple sensitivities for coordination on distribution boards.<\/p>\n<section id=\"overview\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>VK007LE combines residual-current and overcurrent protection into a single modular device<br \/>\nfor feeders and branch circuits. With rated voltages of <strong>AC 240 V<\/strong> (single-phase)<br \/>\n\u0648 <strong>AC 415 V<\/strong> (three-phase), and breaking capacity options of<br \/>\n<strong>4.5 \/ 6 kA<\/strong>, it adapts to different fault-level environments. Type AC and<br \/>\nType A options with <strong>I\u0394n 30 \/ 100 \/ 300 \/ 500 mA<\/strong> help achieve selectivity and<br \/>\nreduce nuisance tripping across residential, commercial and light-industrial panels.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li>Poles: <strong>1P+N \/ 2P \/ 3P \/ 3P+N \/ 4P<\/strong><\/li>\n<li>Rated current (In): <strong>6\u201363 A<\/strong><\/li>\n<li>Rated voltage (Ue): <strong>AC 240 V<\/strong> (single-phase) &amp; <strong>AC 415 V<\/strong> (three-phase)<\/li>\n<li>Frequency: <strong>50\/60 \u0647\u0631\u062a\u0632<\/strong><\/li>\n<li>Residual current type: <strong>Type AC \/ Type A<\/strong><\/li>\n<li>Sensitivity (I\u0394n): <strong>30 \/ 100 \/ 300 \/ 500 mA<\/strong><\/li>\n<li>Breaking capacity (Icn): <strong>4.5 \/ 6 kA<\/strong><\/li>\n<li>Mounting: DIN-rail; front test button (T); front wiring<\/li>\n<li>Certifications: <strong>SEMKO, UKCA, CE, SAA<\/strong><\/li>\n<\/ul>\n<\/section>\n<section id=\"technical-data\">\n<h2>RCBO Breaker Technical Data \u2014 VK007LE<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>VK007LE<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/td>\n<td>1P+N \/ 2P \/ 3P \/ 3P+N \/ 4P<\/td>\n<\/tr>\n<tr>\n<td>Rated current (In)<\/td>\n<td>6\u201363 A<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage (Ue)<\/td>\n<td>AC 240 V (1-\/2-pole); AC 415 V (3-\/4-pole)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0628\u0642\u064a<\/td>\n<td>Type AC \/ Type A<\/td>\n<\/tr>\n<tr>\n<td>Rated residual current (I\u0394n)<\/td>\n<td>30 \/ 100 \/ 300 \/ 500 mA<\/td>\n<\/tr>\n<tr>\n<td>Breaking capacity (Icn)<\/td>\n<td>4.5 \/ 6 kA<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td>DIN-rail; front wiring; test button (T)<\/td>\n<\/tr>\n<tr>\n<td>Recommended use<\/td>\n<td>Feeders \/ branches in residential, commercial, and light-industrial boards<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a<\/td>\n<td>SEMKO, UKCA, CE, SAA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"applications\">\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Single-phase and three-phase distribution with coordinated protection<\/li>\n<li>Feeder circuits requiring higher I\u0394n (100\u2013500 mA) for selectivity<\/li>\n<li>Public\/commercial buildings and light-industrial panels up to 63 A<\/li>\n<\/ul>\n<\/section>\n<section id=\"media\">&nbsp;<\/p>\n<\/section>\n<section id=\"certs\">\n<h2>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644<\/h2>\n<p>Designed for use on 50\/60 Hz systems with compliance to relevant product standards.<br \/>\nCertified by <strong>SEMKO, UKCA, CE, SAA<\/strong>. Check local codes for coordination and selectivity.<\/p>\n<\/section>\n<section id=\"faq\">\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<details>\n<summary>When should I choose 4P instead of 3P or 3P+N?<\/summary>\n<div>\n<p>\u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 <strong>4P<\/strong> when full neutral switching\/isolation is required on three-phase systems.<br \/>\n<strong>3P<\/strong> suits loads without neutral; <strong>3P+N<\/strong> suits systems that need a solid neutral without switching.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>How do I select the I\u0394n for a feeder rcbo breaker?<\/summary>\n<div>\n<p>Upstream devices often use higher sensitivities (e.g., 100\u2013500 mA) to maintain selectivity with downstream 30 mA RCBO\/RCDs. Choose per local codes and coordination studies.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>What is the difference between Type AC and Type A?<\/summary>\n<div>\n<p>\u0627\u0644\u0646\u0648\u0639 <strong>\u0645\u0643\u064a\u0641 \u0627\u0644\u0647\u0648\u0627\u0621<\/strong> responds to sinusoidal AC residual currents; Type <strong>A<\/strong> also detects pulsating DC components.<br \/>\nSelect Type A for circuits with electronic loads (SMPS, dimmers, VFD inputs) when required by codes.<\/p>\n<\/div>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"345\" data-end=\"465\">\n<p data-start=\"347\" data-end=\"465\"><strong data-start=\"347\" data-end=\"363\">rcbo breaker<\/strong> VK007LE with <strong data-start=\"377\" data-end=\"399\">multi-pole options<\/strong> (1P+N \/ 2P \/ 3P \/ 3P+N \/ 4P) for single- &amp; three-phase systems.<\/p>\n<\/li>\n<li data-start=\"466\" data-end=\"552\">\n<p data-start=\"468\" data-end=\"552\"><strong data-start=\"468\" data-end=\"480\">In 6\u201363A<\/strong>, <strong data-start=\"482\" data-end=\"502\">Type AC \/ Type A<\/strong>, sensitivities <strong data-start=\"518\" data-end=\"549\">I\u0394n 30 \/ 100 \/ 300 \/ 500 mA<\/strong>.<\/p>\n<\/li>\n<li data-start=\"553\" data-end=\"650\">\n<p data-start=\"555\" data-end=\"650\"><strong data-start=\"555\" data-end=\"573\">Icn 4.5 \/ 6 kA<\/strong>, <strong data-start=\"575\" data-end=\"595\">Ue 240 V &amp; 415 V<\/strong>, 50\/60 Hz; certifications <strong data-start=\"622\" data-end=\"649\">SEMKO \/ UKCA \/ CE \/ SAA<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1782,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[36],"product_tag":[],"class_list":{"0":"post-1555","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rcbo","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1555"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1782"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1555"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1555"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1555"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}