{"id":1488,"date":"2025-09-12T06:05:31","date_gmt":"2025-09-12T06:05:31","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1488"},"modified":"2025-09-12T06:13:47","modified_gmt":"2025-09-12T06:13:47","slug":"kgld-dual-power-automatic-transfer-switch","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/kgld-dual-power-automatic-transfer-switch\/","title":{"rendered":"KGLD Dual Power Automatic Transfer Switch (20\u20133200A)"},"content":{"rendered":"<section id=\"overview\">\n<p data-start=\"275\" data-end=\"742\">\u0625\u0646 <strong data-start=\"279\" data-end=\"337\">KGLD Series Dual Power Automatic Transfer Switch (ATS)<\/strong> is a reliable <strong data-start=\"352\" data-end=\"392\">dual power automatic transfer switch<\/strong> designed for switching between main and standby power or grid and generator.<br data-start=\"469\" data-end=\"472\" \/>With a compact design, high switching speed, and compliance with IEC 60947-6-1, the KGLD series ensures stable operation in critical facilities.<br data-start=\"616\" data-end=\"619\" \/>It provides automatic transfer, electrical and mechanical interlock, and an optional forced \u201c0\u201d position for maintenance.<\/p>\n<h3 data-start=\"744\" data-end=\"760\">\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul data-start=\"761\" data-end=\"1044\">\n<li data-start=\"761\" data-end=\"826\">\n<p data-start=\"763\" data-end=\"826\">Hospitals, banks, and data centers requiring continuous power<\/p>\n<\/li>\n<li data-start=\"827\" data-end=\"898\">\n<p data-start=\"829\" data-end=\"898\">Industrial facilities using <strong data-start=\"857\" data-end=\"886\">automatic transfer switch<\/strong> equipment<\/p>\n<\/li>\n<li data-start=\"899\" data-end=\"969\">\n<p data-start=\"901\" data-end=\"969\">Residential and commercial buildings with dual source power supply<\/p>\n<\/li>\n<li data-start=\"970\" data-end=\"1044\">\n<p data-start=\"972\" data-end=\"1044\">Generator backup systems with <strong data-start=\"1002\" data-end=\"1042\">dual power automatic transfer switch<\/strong><\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1046\" data-end=\"1062\">\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul data-start=\"1063\" data-end=\"1528\">\n<li data-start=\"1063\" data-end=\"1141\">\n<p data-start=\"1065\" data-end=\"1141\">Wide current range: 20\u20131600A, suitable for various ATS switch applications<\/p>\n<\/li>\n<li data-start=\"1142\" data-end=\"1199\">\n<p data-start=\"1144\" data-end=\"1199\">Rated working voltage: AC400V, insulation up to 1000V<\/p>\n<\/li>\n<li data-start=\"1200\" data-end=\"1244\">\n<p data-start=\"1202\" data-end=\"1244\">High short-circuit capacity: up to 120kA<\/p>\n<\/li>\n<li data-start=\"1245\" data-end=\"1291\">\n<p data-start=\"1247\" data-end=\"1291\">Fast switching: conversion time 0.45s\u20131.2s<\/p>\n<\/li>\n<li data-start=\"1292\" data-end=\"1344\">\n<p data-start=\"1294\" data-end=\"1344\">Meets IEC 60947-6-1 \/ GB\/T14048.11 ATS standards<\/p>\n<\/li>\n<li data-start=\"1345\" data-end=\"1402\">\n<p data-start=\"1347\" data-end=\"1402\">Supports both manual and automatic transfer operation<\/p>\n<\/li>\n<li data-start=\"1403\" data-end=\"1528\">\n<p data-start=\"1405\" data-end=\"1528\">Available in 3P and 4P models, ideal as a <strong data-start=\"1447\" data-end=\"1487\">dual power automatic transfer switch<\/strong> for commercial and industrial projects<\/p>\n<\/li>\n<\/ul>\n<\/section>\n<section id=\"parameters\">\n<h2>Main Technical Parameters<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"6\">\n<thead>\n<tr>\n<th>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u062f\u0631 (\u0623\u0645\u0628\u064a\u0631)<\/th>\n<th>Rated Insulation Voltage Ui (V)<\/th>\n<th>Rated Impulse Withstand Voltage Uimp (kV)<\/th>\n<th>Rated Working Voltage Ue (V)<\/th>\n<th>AC-31A Rated Current (A)<\/th>\n<th>AC-35A Rated Current (A)<\/th>\n<th>AC-33A Rated Current (A)<\/th>\n<th>Rated Making Capacity<\/th>\n<th>Rated Breaking Capacity<\/th>\n<th>Rated Limited Short Circuit Capacity (kA)<\/th>\n<th>Rated Short-time Withstand Current (kA)<\/th>\n<th>Conversion Time I\u2194II (s)<\/th>\n<th>Control Voltage<\/th>\n<th>Motor Power Start (W)<\/th>\n<th>Motor Power Normal (W)<\/th>\n<th>Weight (kg)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>20<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>63<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>63<\/td>\n<td>63<\/td>\n<td>63<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>300<\/td>\n<td>55<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<td>125<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>325<\/td>\n<td>62<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>160<\/td>\n<td>160<\/td>\n<td>160<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>62<\/td>\n<td>8.8<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>7<\/td>\n<td>0.45<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>62<\/td>\n<td>9.0<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>9<\/td>\n<td>0.6<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>74<\/td>\n<td>16.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>750<\/td>\n<td>8<\/td>\n<td>AC400<\/td>\n<td>630<\/td>\n<td>630<\/td>\n<td>630<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>50<\/td>\n<td>9<\/td>\n<td>0.6<\/td>\n<td>AC220<\/td>\n<td>335<\/td>\n<td>74<\/td>\n<td>17.0<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>70<\/td>\n<td>13<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>90<\/td>\n<td>32.0<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>70<\/td>\n<td>26<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>36.0<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1250<\/td>\n<td>1000<\/td>\n<td>800<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>100<\/td>\n<td>50<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>40.0<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>12<\/td>\n<td>AC400<\/td>\n<td>1600<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>10 Ie<\/td>\n<td>8 Ie<\/td>\n<td>120<\/td>\n<td>50<\/td>\n<td>1.2<\/td>\n<td>AC220<\/td>\n<td>440<\/td>\n<td>98<\/td>\n<td>43.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h2>Main Circuit Wiring<\/h2>\n<p>The KGLD automatic transfer switch provides multiple wiring modes depending on system design, including:<\/p>\n<ul>\n<li>Economical connection type (below 100A)<\/li>\n<li>Passive signal + active fire terminal connection mode (100\u2013630A)<\/li>\n<li>Fully automatic connection (160\u20131600A)<\/li>\n<li>Full automatic \u201c0\u201d forced setting (both sources disconnected)<\/li>\n<li>Generator signal output connection mode<\/li>\n<li>Automatic + Manual (remote control)<\/li>\n<li>Wiring with controller (100\u20131600A)<\/li>\n<\/ul>\n<p><em>Detailed wiring diagrams are available in the product catalog and should be strictly followed during installation.<\/em><\/p>\n<\/section>\n<section id=\"standards\">\n<h2>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644<\/h2>\n<p>The KGLD series conforms to the following international standards:<\/p>\n<ul>\n<li>IEC 60947-1 \/ GB\/T 14048.1 (Low-voltage switchgear and controlgear \u2013 General rules)<\/li>\n<li>IEC 60947-3 \/ GB\/T 14048.3 (Switch disconnectors, isolators, fuse-combination units)<\/li>\n<li>IEC 60947-6-1 \/ GB\/T 14048.11 (Automatic transfer switching equipment \u2013 ATS)<\/li>\n<li>Certified for safety, performance, and long service life<\/li>\n<\/ul>\n<\/section>\n<section id=\"selection-guide\">\n<h2>Selection Guide<\/h2>\n<p>When choosing a KGLD automatic transfer switch, consider the following factors:<\/p>\n<ol>\n<li><strong>Rated Current (20A\u20131600A)<\/strong> \u2192 Select based on total load.<\/li>\n<li><strong>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/strong> \u2192 3P for three-phase three-wire, 4P for three-phase four-wire systems.<\/li>\n<li><strong>Control Method<\/strong> \u2192 Automatic or manual; remote control optional.<\/li>\n<li><strong>Conversion Time<\/strong> \u2192 0.45s\u20131.2s depending on model.<\/li>\n<li><strong>Short-circuit Capacity<\/strong> \u2192 Up to 120kA for larger ratings.<\/li>\n<li><strong>Installation Method<\/strong> \u2192 Panel mounted or door-mounted handle.<\/li>\n<li><strong>Standards &amp; Certification<\/strong> \u2192 Verify IEC\/GB conformity and project compliance.<\/li>\n<\/ol>\n<\/section>\n<section id=\"faq\">\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<details>\n<summary>What is the main difference between KGLD and KGQ2 series?<\/summary>\n<p>KGLD is motor-driven automatic ATS with wide current range (20\u20131600A), while KGQ2 focuses on molded case dual power switches with different application emphasis.<\/p>\n<\/details>\n<details>\n<summary>Can KGLD be used with a generator as backup?<\/summary>\n<p>Yes. It supports grid-to-generator transfer, with automatic voltage detection and secure switching.<\/p>\n<\/details>\n<details>\n<summary>Does KGLD support remote control?<\/summary>\n<p>Yes, wiring modes include manual remote control and controller-based operation for smart systems.<\/p>\n<\/details>\n<details>\n<summary>What is the service life of KGLD?<\/summary>\n<p>Mechanical endurance \u22658000 operations, electrical endurance \u22656000 operations under rated conditions.<\/p>\n<\/details>\n<details>\n<summary>Is it certified?<\/summary>\n<p>Yes, compliant with IEC 60947-6-1, IEC 60947-3, GB\/T14048.11, and related standards.<\/p>\n<\/details>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Kuangya KGLD series isolated dual power automatic transfer switch (ATS), covering 20A\u20133200A, designed for reliable power grid \u2194 generator changeover.<\/p>\n<p>Features fast switching, integrated ATS controller, motor drive mechanism, high dielectric withstand, and &gt;8000 operations lifespan.<\/p>\n<p>Suitable for hospitals, banks, high-rise buildings, industrial plants, and other critical applications requiring uninterrupted power supply.<\/p>","protected":false},"featured_media":1491,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[32],"product_tag":[],"class_list":{"0":"post-1488","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-transfer-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1488","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1488"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1491"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1488"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1488"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1488"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1488"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}