{"id":1424,"date":"2025-09-10T10:45:02","date_gmt":"2025-09-10T10:45:02","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1424"},"modified":"2025-09-16T09:52:08","modified_gmt":"2025-09-16T09:52:08","slug":"type-2-surge-protection-device-n-pe","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/type-2-surge-protection-device-n-pe\/","title":{"rendered":"\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 2 N-PE KYSPD-40T2-1-1+1 | \u0643\u0648\u0627\u0646\u062c\u064a\u0627"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-40T2-1+1 is a <strong>Type 2 surge protection device N-PE<\/strong><br \/>\ndesigned for single-phase 230\/400 V AC TN and TT systems. It adopts a 1+1 topology,<br \/>\nusing MOV between L\u2013N for surge suppression and a GDT between N\u2013PE for safe<br \/>\ndischarge to earth.This SPD is ideal for distribution panels requiring enhanced protection against<br \/>\nswitching transients and indirect lightning surges. It features pluggable modules<br \/>\nfor easy replacement, integrated thermal disconnectors with visible indicators,<br \/>\nand optional RC contacts for remote fault monitoring.<\/p>\n<\/section>\n<section id=\"features\">\n<h3>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul>\n<li>Type 2 SPD with 1+1 topology: L\u2013N (MOV), N\u2013PE (GDT).<\/li>\n<li>Nominal discharge current (In): 20 kA (8\/20 \u03bcs).<\/li>\n<li>Maximum discharge current (Imax): 40 kA (8\/20 \u03bcs).<\/li>\n<li>Voltage protection level (Up): \u2264 1.3\u20132.0 kV depending on Uc.<\/li>\n<li>Response time: &lt; 25 ns (L\u2013N), &lt; 100 ns (N\u2013PE).<\/li>\n<li>Back-up fuse: max 125 A gL\/gG; ISCCR 25 kA AC.<\/li>\n<li>Pluggable cartridges with thermal disconnector and green\/red status indicator.<\/li>\n<li>Optional RC contacts: AC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A.<\/li>\n<li>Housing UL94 V-0 thermoplastic, IP20; operating temperature -40 \u00b0C to +80 \u00b0C.<\/li>\n<li>DIN rail mounting (35 mm, EN 60715); IEC\/EN 61643-11 compliant.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0631\u0645\u0632 \u0627\u0644\u0645\u0646\u062a\u062c<\/th>\n<td>KYSPD-40T2-1-1+1<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0641\u0626\u0629<\/th>\n<td>Type 2 surge protection device N-PE<\/td>\n<\/tr>\n<tr>\n<th>Nominal System Voltage<\/th>\n<td>230\/400 V AC<\/td>\n<\/tr>\n<tr>\n<th>Topology<\/th>\n<td>1+1 (L\u2013N MOV, N\u2013PE GDT)<\/td>\n<\/tr>\n<tr>\n<th>Continuous Operating Voltage (Uc)<\/th>\n<td>230 \/ 320 \/ 385 V<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (\u062f\u0627\u062e\u0644\u064a\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/th>\n<td>20 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>Maximum Discharge Current (Imax, 8\/20 \u03bcs)<\/th>\n<td>40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0645\u0633\u062a\u0648\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649)<\/th>\n<td>\u2264 1.3\u20132.0 kV<\/td>\n<\/tr>\n<tr>\n<th>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629<\/th>\n<td>&lt; 25 ns (L\u2013N) \/ &lt; 100 ns (N\u2013PE)<\/td>\n<\/tr>\n<tr>\n<th>Back-Up Fuse (max)<\/th>\n<td>125 \u0623\u0645\u0628\u064a\u0631\/\u063a\u0645\/\u063a\u0645<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u0635\u0646\u064a\u0641 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (ISCCR)<\/th>\n<td>25 kA AC<\/td>\n<\/tr>\n<tr>\n<th>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<td>-40 \u00b0C to +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>35 mm DIN rail, EN 60715<\/td>\n<\/tr>\n<tr>\n<th>Enclosure \/ Protection<\/th>\n<td>Thermoplastic UL94 V-0 \/ IP20<\/td>\n<\/tr>\n<tr>\n<th>Remote Signaling (RC)<\/th>\n<td>Optional; AC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h3>\n<p>Connection diagram type 2 surge protection device N-PE KYSPD-40T2-1+1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1422\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram--277x300.png\" alt=\"Connection diagram type 2 surge protection device N-PE KYSPD-40T2-1+1\" width=\"406\" height=\"440\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram--277x300.png 277w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram--300x325.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram-.png 495w\" sizes=\"auto, (max-width: 406px) 100vw, 406px\" \/><\/p>\n<p>Dimensions type 2 surge protection device N-PE KYSPD-40T2-1+1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1423\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P1-dimension-300x244.png\" alt=\"Dimensions type 2 surge protection device N-PE KYSPD-40T2-1+1\" width=\"401\" height=\"326\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P1-dimension-300x244.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P1-dimension.png 507w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \/><\/p>\n<\/section>\n<section id=\"applications\">\n<h3>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul>\n<li>Main and sub-distribution boards in residential, commercial, and industrial facilities.<\/li>\n<li>Protection of single-phase TN\/TT networks requiring N\u2013PE discharge path.<\/li>\n<li>Coordination with upstream Type 1 SPDs for complete system protection.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n<ul>\n<li><strong>What topology does KYSPD-40T2-1+1 use?<\/strong> 1+1 topology with MOV (L\u2013N) and GDT (N\u2013PE).<\/li>\n<li><strong>\u0645\u0627 \u0647\u0648 \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0645\u0641\u0627\u062c\u0626 \u0641\u064a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u061f<\/strong> In 20 kA, Imax 40 kA.<\/li>\n<li><strong>\u0645\u0627 \u0647\u064a \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u064a \u062a\u0646\u0627\u0633\u0628\u0647\u0627\u061f<\/strong> Single-phase TN and TT 230\/400 V AC systems.<\/li>\n<li><strong>Does it provide remote monitoring?<\/strong> \u0646\u0639\u0645\u060c \u062a\u062a\u0648\u0641\u0631 \u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 RC \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629.<\/li>\n<li><strong>\u0645\u0627 \u0647\u0648 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u0644\u0641\u062a\u064a\u0644 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a\u061f<\/strong> 125 A gL\/gG.<\/li>\n<\/ul>\n<\/section>\n<section id=\"cta\">For detailed pricing and technical support, please <a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a>.Explore more Kuangya solutions: <a href=\"\/ar\/dc-spd\/\">DC SPD<\/a>, <a href=\"\/ar\/ac-surge-protective-device\/\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"620\" data-end=\"745\">\n<p data-start=\"622\" data-end=\"745\"><strong data-start=\"622\" data-end=\"661\">Type 2 surge protection device N-PE<\/strong> \u0645\u0639 <strong data-start=\"667\" data-end=\"704\">1+1 topology (L\u2013N MOV + N\u2013PE GDT)<\/strong> for 230\/400 V AC single-phase systems.<\/p>\n<\/li>\n<li data-start=\"746\" data-end=\"880\">\n<p data-start=\"748\" data-end=\"880\">Discharge ratings: <strong data-start=\"767\" data-end=\"789\">In 20 kA (8\/20 \u03bcs)<\/strong>, <strong data-start=\"791\" data-end=\"815\">Imax 40 kA (8\/20 \u03bcs)<\/strong>; voltage protection level <strong data-start=\"842\" data-end=\"861\">Up \u2264 1.3\u20132.0 kV<\/strong> depending on Uc.<\/p>\n<\/li>\n<li data-start=\"881\" data-end=\"1021\">\n<p data-start=\"883\" data-end=\"1021\">Pluggable cartridge design with thermal disconnector and status indicator, optional <strong data-start=\"967\" data-end=\"999\">RC remote signaling contacts<\/strong>, DIN rail mounting.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1596,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1424","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1424","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1424"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1596"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1424"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1424"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1424"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1424"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}