{"id":1424,"date":"2025-09-10T10:45:02","date_gmt":"2025-09-10T10:45:02","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1424"},"modified":"2025-09-16T09:52:08","modified_gmt":"2025-09-16T09:52:08","slug":"type-2-surge-protection-device-n-pe","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/type-2-surge-protection-device-n-pe\/","title":{"rendered":"\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 2 N-PE KYSPD-40T2-1-1+1 | \u0643\u0648\u0627\u0646\u062c\u064a\u0627"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-40T2-1+1 is a <strong>Type 2 surge protection device N-PE<\/strong><br \/>\ndesigned for single-phase 230\/400 V AC TN and TT systems. It adopts a 1+1 topology,<br \/>\nusing MOV between L\u2013N for surge suppression and a GDT between N\u2013PE for safe<br \/>\ndischarge to earth.This SPD is ideal for distribution panels requiring enhanced protection against<br \/>\nswitching transients and indirect lightning surges. It features pluggable modules<br \/>\nfor easy replacement, integrated thermal disconnectors with visible indicators,<br \/>\nand optional RC contacts for remote fault monitoring.<\/p>\n<\/section>\n<section id=\"features\">\n<h3>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul>\n<li>Type 2 SPD with 1+1 topology: L\u2013N (MOV), N\u2013PE (GDT).<\/li>\n<li>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (In): 20 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 (8\/20 \u03bcs).<\/li>\n<li>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (Imax): 40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 (8\/20 \u03bcs).<\/li>\n<li>\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649): \u2264 1.3-2.0 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u062d\u0633\u0628 Uc.<\/li>\n<li>\u0632\u0645\u0646 \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629: &lt; 25 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629 (L-N)\u060c &lt; 100 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629 (N-PE).<\/li>\n<li>\u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a\u0629: \u0628\u062d\u062f \u0623\u0642\u0635\u0649 125 \u0623\u0645\u0628\u064a\u0631\/\u062c\/\u062c\u061b \u0648\u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f 25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631.<\/li>\n<li>Pluggable cartridges with thermal disconnector and green\/red status indicator.<\/li>\n<li>Optional RC contacts: AC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A.<\/li>\n<li>\u0645\u0628\u064a\u062a \u0645\u0646 \u0627\u0644\u0628\u0644\u0627\u0633\u062a\u064a\u0643 \u0627\u0644\u062d\u0631\u0627\u0631\u064a UL94 V-0\u060c IP20\u061b \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 -40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0625\u0644\u0649 +80 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629.<\/li>\n<li>\u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0639\u0644\u0649 \u0633\u0643\u0629 DIN (35 \u0645\u0645\u060c EN 60715)\u061b \u0645\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 IEC\/EN 61643-11.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0631\u0645\u0632 \u0627\u0644\u0645\u0646\u062a\u062c<\/th>\n<td>KYSPD-40T2-1-1+1<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0641\u0626\u0629<\/th>\n<td>Type 2 surge protection device N-PE<\/td>\n<\/tr>\n<tr>\n<th>\u062c\u0647\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0627\u0633\u0645\u064a<\/th>\n<td>230\/400 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 230\/400 \u0641\u0648\u0644\u062a<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0637\u0648\u0628\u0648\u0644\u0648\u062c\u064a\u0627<\/th>\n<td>1+1 (\u0644-\u0646 \u0645.\u0645.\u0645.\u0645.\u0648\u060c \u0646-\u0628.\u0645.\u0645.\u0645.\u0645.\u0645.\u0645.\u0645)<\/td>\n<\/tr>\n<tr>\n<th>\u062c\u0647\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 (Uc)<\/th>\n<td>230 \/ 320 \/ 385 V<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (\u062f\u0627\u062e\u0644\u064a\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/th>\n<td>20 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (Imax\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/th>\n<td>40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0645\u0633\u062a\u0648\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649)<\/th>\n<td>\u2264 1.3 - 2.0 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/td>\n<\/tr>\n<tr>\n<th>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629<\/th>\n<td>&lt; 25 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629 (L-N) \/ &lt; 100 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629 (N-PE)<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a (\u0628\u062d\u062f \u0623\u0642\u0635\u0649)<\/th>\n<td>125 \u0623\u0645\u0628\u064a\u0631\/\u063a\u0645\/\u063a\u0645<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u0635\u0646\u064a\u0641 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (ISCCR)<\/th>\n<td>25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f<\/td>\n<\/tr>\n<tr>\n<th>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<td>-40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0625\u0644\u0649 +80 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>\u0633\u0643\u0629 DIN \u0645\u0642\u0627\u0633 35 \u0645\u0645\u060c EN 60715<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0636\u0645\u064a\u0645\u0629\/\u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/th>\n<td>\u0644\u062f\u0646 \u0628\u0627\u0644\u062d\u0631\u0627\u0631\u0629 UL94 V-0\/ IP20<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f (RC)<\/th>\n<td>\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u061b \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 250 \u0641\u0648\u0644\u062a \/ 0.5 \u0623\u0645\u0628\u064a\u0631\u061b \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 250 \u0641\u0648\u0644\u062a \/ 0.1 \u0623\u0645\u0628\u064a\u0631\u061b 125 \u0641\u0648\u0644\u062a \/ 0.2 \u0623\u0645\u0628\u064a\u0631\u061b 75 \u0641\u0648\u0644\u062a \/ 0.5 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h3>\n<p>Connection diagram type 2 surge protection device N-PE KYSPD-40T2-1+1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1422\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram--277x300.png\" alt=\"Connection diagram type 2 surge protection device N-PE KYSPD-40T2-1+1\" width=\"406\" height=\"440\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram--277x300.png 277w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram--300x325.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P1-wiring-diagram-.png 495w\" sizes=\"auto, (max-width: 406px) 100vw, 406px\" \/><\/p>\n<p>Dimensions type 2 surge protection device N-PE KYSPD-40T2-1+1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1423\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P1-dimension-300x244.png\" alt=\"Dimensions type 2 surge protection device N-PE KYSPD-40T2-1+1\" width=\"401\" height=\"326\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P1-dimension-300x244.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P1-dimension.png 507w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \/><\/p>\n<\/section>\n<section id=\"applications\">\n<h3>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul>\n<li>\u0644\u0648\u062d\u0627\u062a \u0627\u0644\u062a\u0648\u0632\u064a\u0639 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629 \u0648\u0627\u0644\u0641\u0631\u0639\u064a\u0629 \u0641\u064a \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u0633\u0643\u0646\u064a\u0629 \u0648\u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629 \u0648\u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629.<\/li>\n<li>Protection of single-phase TN\/TT networks requiring N\u2013PE discharge path.<\/li>\n<li>Coordination with upstream Type 1 SPDs for complete system protection.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n<ul>\n<li><strong>What topology does KYSPD-40T2-1+1 use?<\/strong> 1+1 topology with MOV (L\u2013N) and GDT (N\u2013PE).<\/li>\n<li><strong>\u0645\u0627 \u0647\u0648 \u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639 \u0627\u0644\u0645\u0641\u0627\u062c\u0626 \u0641\u064a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u061f<\/strong> In 20 kA, Imax 40 kA.<\/li>\n<li><strong>\u0645\u0627 \u0647\u064a \u0627\u0644\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u062a\u064a \u062a\u0646\u0627\u0633\u0628\u0647\u0627\u061f<\/strong> Single-phase TN and TT 230\/400 V AC systems.<\/li>\n<li><strong>Does it provide remote monitoring?<\/strong> \u0646\u0639\u0645\u060c \u062a\u062a\u0648\u0641\u0631 \u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 RC \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629.<\/li>\n<li><strong>\u0645\u0627 \u0647\u0648 \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u0644\u0641\u062a\u064a\u0644 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a\u061f<\/strong> 125 \u0623\u0645\u0628\u064a\u0631\/\u063a\u0631\u0627\u0645\/\u063a\u0631\u0627\u0645.<\/li>\n<\/ul>\n<\/section>\n<section id=\"cta\">\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a\u0629 \u0648\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0641\u0646\u064a\u060c \u064a\u0631\u062c\u0649 <a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a>.\u0627\u0633\u062a\u0643\u0634\u0641 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u062d\u0644\u0648\u0644 \u0643\u0648\u0627\u0646\u062c\u064a\u0627: <a href=\"\/ar\/dc-spd\/\">DC SPD<\/a>, <a href=\"\/ar\/ac-surge-protective-device\/\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"620\" data-end=\"745\">\n<p data-start=\"622\" data-end=\"745\"><strong data-start=\"622\" data-end=\"661\">Type 2 surge protection device N-PE<\/strong> \u0645\u0639 <strong data-start=\"667\" data-end=\"704\">1+1 topology (L\u2013N MOV + N\u2013PE GDT)<\/strong> for 230\/400 V AC single-phase systems.<\/p>\n<\/li>\n<li data-start=\"746\" data-end=\"880\">\n<p data-start=\"748\" data-end=\"880\">Discharge ratings: <strong data-start=\"767\" data-end=\"789\">In 20 kA (8\/20 \u03bcs)<\/strong>, <strong data-start=\"791\" data-end=\"815\">Imax 40 kA (8\/20 \u03bcs)<\/strong>; voltage protection level <strong data-start=\"842\" data-end=\"861\">\u062d\u062a\u0649 \u2264 1.3-2.0 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/strong> \u062d\u0633\u0628 UC.<\/p>\n<\/li>\n<li data-start=\"881\" data-end=\"1021\">\n<p data-start=\"883\" data-end=\"1021\">Pluggable cartridge design with thermal disconnector and status indicator, optional <strong data-start=\"967\" data-end=\"999\">RC remote signaling contacts<\/strong>, DIN rail mounting.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1596,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":["post-1424","product","type-product","status-publish","has-post-thumbnail","product_cat-ac-spd","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1424","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1424"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1596"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1424"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1424"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1424"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1424"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}