{"id":1386,"date":"2025-09-10T08:57:23","date_gmt":"2025-09-10T08:57:23","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1386"},"modified":"2025-12-01T06:44:28","modified_gmt":"2025-12-01T06:44:28","slug":"type-2-3-surge-protection-device-1p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/type-2-3-surge-protection-device-1p\/","title":{"rendered":"\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 2+3 1P KYSPD-20T2+3-1P | \u0643\u0648\u0627\u0646\u062c\u064a\u0627"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-20T2+3-1P is a compact <strong>type 2+3 surge protection device 1P<\/strong><br \/>\ndesigned for single-phase electrical panels at 230 V AC. It combines Type 2 and Type 3 protection<br \/>\nclasses, making it suitable for downstream circuits where sensitive equipment requires enhanced<br \/>\nsurge suppression.This SPD features MOV-based surge absorption with a pluggable cartridge design,<br \/>\nintegrated thermal disconnector, and clear green\/red status indicator. Optional RC contacts<br \/>\nallow remote fault signaling for integration with building management systems or control panels.<\/p>\n<\/section>\n<section id=\"features\">\n<h3>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul>\n<li>Class II+III \/ Type 2+3 surge protective device (1P).<\/li>\n<li>Nominal discharge current (In): 10 kA (8\/20 \u03bcs).<\/li>\n<li>Maximum discharge current (Imax): 20 kA (8\/20 \u03bcs).<\/li>\n<li>Voltage protection level (Up): \u2264 0.3\u20131.8 kV depending on Uc (75\u2013440 V).<\/li>\n<li>Fast response time &lt; 25 ns for reliable transient suppression.<\/li>\n<li>Back-up fuse: max 63 A gL\/gG; ISCCR 10 kA AC.<\/li>\n<li>Optional RC signaling contacts: AC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A.<\/li>\n<li>Thermoplastic UL94 V-0 housing, IP20; operating temperature -40 \u00b0C to +70 \u00b0C.<\/li>\n<li>DIN rail mounting (35 mm, EN 60715); IEC\/EN 61643-11 compliant.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0631\u0645\u0632 \u0627\u0644\u0645\u0646\u062a\u062c<\/th>\n<td>KYSPD-20T2+3-1P<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0641\u0626\u0629<\/th>\n<td>Type 2+3 surge protection device 1P<\/td>\n<\/tr>\n<tr>\n<th>Nominal System Voltage<\/th>\n<td>230 V AC<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0623\u0639\u0645\u062f\u0629<\/th>\n<td>1P (Single-phase)<\/td>\n<\/tr>\n<tr>\n<th>Continuous Operating Voltage (Uc)<\/th>\n<td>75 \/ 150 \/ 275 \/ 320 \/ 385 \/ 440 V<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (\u062f\u0627\u062e\u0644\u064a\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/th>\n<td>10 kA<\/td>\n<\/tr>\n<tr>\n<th>Maximum Discharge Current (Imax, 8\/20 \u03bcs)<\/th>\n<td>20 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0645\u0633\u062a\u0648\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649)<\/th>\n<td>\u2264 0.3\u20131.8 kV<\/td>\n<\/tr>\n<tr>\n<th>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629<\/th>\n<td>&lt; 25 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<th>Back-Up Fuse (max)<\/th>\n<td>63 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u0635\u0646\u064a\u0641 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (ISCCR)<\/th>\n<td>10 kA AC<\/td>\n<\/tr>\n<tr>\n<th>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<td>-40 \u00b0C to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>35 mm DIN rail, EN 60715<\/td>\n<\/tr>\n<tr>\n<th>Enclosure \/ Protection<\/th>\n<td>Thermoplastic UL94 V-0 \/ IP20<\/td>\n<\/tr>\n<tr>\n<th>Remote Signaling (RC)<\/th>\n<td>Optional; AC 250 V \/ 0.5 A; DC 250 V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h3>\n<p>Connection diagram type 2+3 surge protection device 1P KYSPD-20T2+3-1P<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1388\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P-wiring-diagram-1-300x276.png\" alt=\"Connection diagram type 2+3 surge protection device 1P KYSPD-20T2+3-1P\" width=\"400\" height=\"368\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P-wiring-diagram-1-300x276.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-1P-wiring-diagram-1.png 533w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/p>\n<p>Dimensions type 2+3 surge protection device 1P KYSPD-20T2+3-1P<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1389\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P-dimension-1-300x280.png\" alt=\"Dimensions type 2+3 surge protection device 1P KYSPD-20T2+3-1P\" width=\"401\" height=\"374\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P-dimension-1-300x280.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-1P-dimension-1.png 441w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \/><\/p>\n<\/section>\n<section id=\"applications\">\n<h3>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul>\n<li>Single-phase distribution panels in residential and office buildings.<\/li>\n<li>Protection of sensitive electronic devices and appliances from transient surges.<\/li>\n<li>Downstream coordination with upstream Type 1 surge arresters in TT\/TN networks.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n<ul>\n<li><strong>What class of SPD is KYSPD-20T2+3-1P?<\/strong> It is Class II+III, Type 2+3 according to IEC\/EN 61643-11.<\/li>\n<li><strong>What is its surge discharge capacity?<\/strong> In 10 kA, Imax 20 kA per pole.<\/li>\n<li><strong>Where can it be installed?<\/strong> In single-phase 230 V AC electrical panels.<\/li>\n<li><strong>Does it provide remote fault signaling?<\/strong> \u0646\u0639\u0645\u060c \u062a\u062a\u0648\u0641\u0631 \u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 RC \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629.<\/li>\n<li><strong>What is the maximum backup fuse rating?<\/strong> 63 A gL\/gG.<\/li>\n<\/ul>\n<\/section>\n<section id=\"cta\">For detailed pricing and technical support, please <a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a>.Explore more Kuangya solutions: <a href=\"\/ar\/dc-spd\/\">DC SPD<\/a>, <a href=\"\/ar\/ac-surge-protective-device\/\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"608\" data-end=\"693\">\n<p data-start=\"610\" data-end=\"693\"><strong data-start=\"610\" data-end=\"649\">Type 2+3 surge protection device 1P<\/strong> for single-phase AC systems at <strong data-start=\"681\" data-end=\"690\">230 V<\/strong>.<\/p>\n<\/li>\n<li data-start=\"694\" data-end=\"799\">\n<p data-start=\"696\" data-end=\"799\">Surge ratings: <strong data-start=\"711\" data-end=\"733\">In 10 kA (8\/20 \u00b5s)<\/strong>, <strong data-start=\"735\" data-end=\"759\">Imax 20 kA (8\/20 \u00b5s)<\/strong>, <strong data-start=\"761\" data-end=\"780\">Up \u2264 0.3\u20131.8 kV<\/strong> depending on Uc.<\/p>\n<\/li>\n<li data-start=\"800\" data-end=\"918\">\n<p data-start=\"802\" data-end=\"918\">Compact pluggable DIN-rail module, thermal disconnector with status indicator, <strong data-start=\"881\" data-end=\"915\">optional RC signaling contacts<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1578,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1386","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1386","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1386"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1578"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1386"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1386"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1386"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}