{"id":1382,"date":"2025-09-10T08:02:42","date_gmt":"2025-09-10T08:02:42","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1382"},"modified":"2025-09-16T09:51:21","modified_gmt":"2025-09-16T09:51:21","slug":"surge-protection-device-for-elevators-kyspd-40t2-31","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/surge-protection-device-for-elevators-kyspd-40t2-31\/","title":{"rendered":"\u062c\u0647\u0627\u0632 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u0635\u0627\u0639\u062f \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u0645\u0635\u0627\u0639\u062f KYSPD-40T2-3-3+1 | \u0643\u0648\u0627\u0646\u062c\u064a\u0627"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-40T2-3+1 is a specialized <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0644\u0644\u0645\u0635\u0627\u0639\u062f<\/strong>,<br \/>\ndesigned to safeguard lift control systems, drives, and associated electrical panels<br \/>\nin residential, commercial, and industrial buildings. Using a 3+1 topology, it provides<br \/>\ncoordinated protection for L-N (MOV) and N-PE (GDT) paths in 230\/400 V AC networks.This device is built for high reliability in vertical transport applications,<br \/>\nwhere electrical disturbances may cause malfunction or downtime. Its pluggable design,<br \/>\nthermal disconnector, and clear status indicators simplify service and ensure safety.<br \/>\nOptional RC contacts allow real-time monitoring and integration with building management systems.<\/p>\n<\/section>\n<section id=\"features\">\n<h3>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul>\n<li>Optimized surge protection for elevator systems (control panels, drives, motors).<\/li>\n<li>3+1 topology: MOV protection L\u2013N and coordinated GDT+MOV protection N\u2013PE.<\/li>\n<li>Nominal discharge current (In): 20 kA (8\/20 \u03bcs); Maximum discharge current (Imax): 40 kA (8\/20 \u03bcs).<\/li>\n<li>\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649): \u2264 1.5-2.0 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u062d\u0633\u0628 Uc.<\/li>\n<li>Fast response time &lt; 25 ns for L\u2013N; &lt; 100 ns for N\u2013PE.<\/li>\n<li>\u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a\u0629: \u0628\u062d\u062f \u0623\u0642\u0635\u0649 125 \u0623\u0645\u0628\u064a\u0631\/\u062c\/\u062c\u061b \u0648\u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f 25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631.<\/li>\n<li>\u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629 \u0644\u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0639\u0646 \u0628\u064f\u0639\u062f RC: \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 250 \u0641\u0648\u0644\u062a \/ 0.5 \u0623\u0645\u0628\u064a\u0631\u061b \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 250 \u0641\u0648\u0644\u062a \/ 0.1 \u0623\u0645\u0628\u064a\u0631\u061b 125 \u0641\u0648\u0644\u062a \/ 0.2 \u0623\u0645\u0628\u064a\u0631\u061b 75 \u0641\u0648\u0644\u062a \/ 0.5 \u0623\u0645\u0628\u064a\u0631.<\/li>\n<li>\u0645\u0628\u064a\u062a IP20\u060c \u0628\u0644\u0627\u0633\u062a\u064a\u0643 \u062d\u0631\u0627\u0631\u064a UL94 V-0\u061b \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 -40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0625\u0644\u0649 +80 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629.<\/li>\n<li>\u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0639\u0644\u0649 \u0633\u0643\u0629 DIN (35 \u0645\u0645\u060c EN 60715)\u061b \u0645\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 IEC\/EN 61643-11.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0631\u0645\u0632 \u0627\u0644\u0645\u0646\u062a\u062c<\/th>\n<td>KYSPD-40T2-3-3+1<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0641\u0626\u0629<\/th>\n<td>Surge protection device for elevators<\/td>\n<\/tr>\n<tr>\n<th>\u062c\u0647\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0627\u0633\u0645\u064a<\/th>\n<td>230\/400 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 230\/400 \u0641\u0648\u0644\u062a<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0637\u0648\u0628\u0648\u0644\u0648\u062c\u064a\u0627<\/th>\n<td>3+1 (L\u2013N MOV, N\u2013PE GDT+MOV)<\/td>\n<\/tr>\n<tr>\n<th>\u062c\u0647\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 (Uc)<\/th>\n<td>230 \u0641\u0648\u0644\u062a \/ 320 \u0641\u0648\u0644\u062a \/ 385 \u0641\u0648\u0644\u062a<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (\u062f\u0627\u062e\u0644\u064a\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/th>\n<td>20 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (Imax\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/th>\n<td>40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0645\u0633\u062a\u0648\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649)<\/th>\n<td>\u2264 1.5 - 2.0 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/td>\n<\/tr>\n<tr>\n<th>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629<\/th>\n<td>&lt; 25 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629 (L-N) \/ &lt; 100 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629 (N-PE)<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a (\u0628\u062d\u062f \u0623\u0642\u0635\u0649)<\/th>\n<td>125 \u0623\u0645\u0628\u064a\u0631\/\u063a\u0645\/\u063a\u0645<\/td>\n<\/tr>\n<tr>\n<th>\u062a\u0635\u0646\u064a\u0641 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (ISCCR)<\/th>\n<td>25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f<\/td>\n<\/tr>\n<tr>\n<th>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<td>-40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0625\u0644\u0649 +80 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>\u0633\u0643\u0629 DIN \u0645\u0642\u0627\u0633 35 \u0645\u0645\u060c EN 60715<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0636\u0645\u064a\u0645\u0629\/\u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/th>\n<td>\u0644\u062f\u0646 \u0628\u0627\u0644\u062d\u0631\u0627\u0631\u0629 UL94 V-0\/ IP20<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f (RC)<\/th>\n<td>\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u061b \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 250 \u0641\u0648\u0644\u062a \/ 0.5 \u0623\u0645\u0628\u064a\u0631\u061b \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631 250 \u0641\u0648\u0644\u062a \/ 0.1 \u0623\u0645\u0628\u064a\u0631\u061b 125 \u0641\u0648\u0644\u062a \/ 0.2 \u0623\u0645\u0628\u064a\u0631\u061b 75 \u0641\u0648\u0644\u062a \/ 0.5 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC\/EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h3>\n<p>Connection diagram surge protection device for elevators KYSPD-40T2-3+1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1384\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-3P1-wiring-diagram--300x210.png\" alt=\"Connection diagram surge protection device for elevators KYSPD-40T2-3+1\" width=\"453\" height=\"317\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-3P1-wiring-diagram--300x210.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-3P1-wiring-diagram--600x420.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-3P1-wiring-diagram-.png 727w\" sizes=\"auto, (max-width: 453px) 100vw, 453px\" \/><\/p>\n<p>Dimensions surge protection device for elevators KYSPD-40T2-3+1<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1385\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-3P1-dimension-300x228.png\" alt=\"Dimensions surge protection device for elevators KYSPD-40T2-3+1\" width=\"455\" height=\"346\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-3P1-dimension-300x228.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-40T2-3P1-dimension.png 544w\" sizes=\"auto, (max-width: 455px) 100vw, 455px\" \/><\/p>\n<\/section>\n<section id=\"applications\">\n<h3>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul>\n<li>Elevator control panels and drive systems in residential and commercial buildings.<\/li>\n<li>Protection of lift equipment from lightning-induced and switching surges.<\/li>\n<li>Building electrical panels requiring coordinated 3+1 surge protection with monitoring.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n<ul>\n<li><strong>Why is this SPD suitable for elevators?<\/strong> It uses a 3+1 topology optimized for protecting sensitive elevator controls and drives.<\/li>\n<li><strong>What is its surge capacity?<\/strong> In 20 kA, Imax 40 kA per path.<\/li>\n<li><strong>\u0647\u0644 \u064a\u062f\u0639\u0645 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629\u061f<\/strong> Yes, optional RC contacts provide remote fault indication.<\/li>\n<li><strong>What is the backup fuse rating?<\/strong> Maximum 125 A gL\/gG.<\/li>\n<li><strong>Which standards does it comply with?<\/strong> IEC\/EN 61643-11.<\/li>\n<\/ul>\n<\/section>\n<section id=\"cta\">\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0623\u0633\u0639\u0627\u0631 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a\u0629 \u0648\u0627\u0644\u062f\u0639\u0645 \u0627\u0644\u0641\u0646\u064a\u060c \u064a\u0631\u062c\u0649 <a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a>.\u0627\u0643\u062a\u0634\u0641 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0645\u0646\u062a\u062c\u0627\u062a \u0643\u0648\u0627\u0646\u062c\u064a\u0627: <a href=\"\/ar\/dc-spd\/\">DC SPD<\/a>, <a href=\"\/ar\/ac-surge-protective-device\/\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"639\" data-end=\"750\">\n<p data-start=\"641\" data-end=\"750\"><strong data-start=\"641\" data-end=\"682\">Surge protection device for elevators<\/strong>, \u0645\u0635\u0645\u0645\u0629 \u0645\u0646 \u0623\u062c\u0644 <strong data-start=\"697\" data-end=\"731\">three-phase + N (3+1 topology)<\/strong> at 230\/400 V AC.<\/p>\n<\/li>\n<li data-start=\"751\" data-end=\"856\">\n<p data-start=\"753\" data-end=\"856\">\u062a\u0642\u064a\u064a\u0645\u0627\u062a \u0627\u0644\u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u0645\u0641\u0627\u062c\u0626\u0629: <strong data-start=\"768\" data-end=\"790\">\u0641\u064a 20 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 (8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/strong>, <strong data-start=\"792\" data-end=\"816\">\u0625\u064a\u0645\u0627\u0643\u0633 40 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 (8\/20 \u0645\u064a\u0643\u0631\u0648 \u0623\u0645\u0628\u064a\u0631)<\/strong>, <strong data-start=\"818\" data-end=\"837\">\u062d\u062a\u0649 \u2264 1.5 - 2.0 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a<\/strong> \u062d\u0633\u0628 UC.<\/p>\n<\/li>\n<li data-start=\"857\" data-end=\"993\">\n<p data-start=\"859\" data-end=\"993\">\u0627\u0644\u0645\u064a\u0632\u0627\u062a <strong data-start=\"868\" data-end=\"890\">L\u2013N MOV + N\u2013PE GDT<\/strong> coordinated protection, pluggable modules, thermal disconnector, optional <strong data-start=\"965\" data-end=\"990\">RC signaling contacts<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1592,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":["post-1382","product","type-product","status-publish","has-post-thumbnail","product_cat-ac-spd","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1382","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1382"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1592"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1382"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1382"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1382"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1382"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}