{"id":1291,"date":"2025-09-09T09:45:59","date_gmt":"2025-09-09T09:45:59","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1291"},"modified":"2025-12-01T06:56:44","modified_gmt":"2025-12-01T06:56:44","slug":"ac-surge-protection-device-3p","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/ac-surge-protection-device-3p\/","title":{"rendered":"AC Surge Protection Device KYSPD-25T1-3P | Kuangya"},"content":{"rendered":"<section id=\"overview\">The Kuangya KYSPD-25T1-3P is a three-pole <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> designed for 230\/400 V AC systems. It provides Class I \/ Type 1 protection against direct lightning currents with an impulse discharge current of 25 kA per pole (10\/350 \u03bcs). This <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> is ideal for installation at the service entrance as the first stage of a coordinated SPD system.<\/section>\n<section id=\"features\">\n<h3>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul>\n<li>Complies with IEC\/EN 61643-11, Category: Class I \/ Type 1.<\/li>\n<li>Three-pole configuration; Iimp 25 kA per pole; In 25 kA; Imax 100 kA.<\/li>\n<li>Nominal system voltage Uo\/Un: 230\/400 V AC.<\/li>\n<li>Uc options: 320 \/ 385 \/ 440 V AC; voltage protection level (Up): ~1.6\u20132.0 kV.<\/li>\n<li>Fast response time &lt; 25 ns; reliable MOV-based design.<\/li>\n<li>Pluggable cartridge with thermal disconnector and visual indicator.<\/li>\n<li>Optional RC contacts for remote status signaling.<\/li>\n<li>Housing: UL94 V-0 thermoplastic; IP20 built-in; DIN 35 mm rail mount.<\/li>\n<li>Trusted as a first-stage <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> for heavy-duty systems.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>\u0627\u0644\u0642\u064a\u0645\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0631\u0645\u0632 \u0627\u0644\u0645\u0646\u062a\u062c<\/td>\n<td>KYSPD-25T1-3P<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0641\u0626\u0629<\/td>\n<td>AC Surge Protection Device (Type 1 \/ Class I)<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0627\u0633\u0645\u064a (Uo\/Un)<\/td>\n<td>230 \/ 400 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649. \u062c\u0647\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 (Uc)<\/td>\n<td>320 \/ 385 \/ 440 V AC<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (\u062f\u0627\u062e\u0644\u064a\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/td>\n<td>25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649. \u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (Imax\u060c 8\/20 \u03bcs)<\/td>\n<td>100 kA<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0646\u062f\u0641\u0627\u0639\u064a (Iimp\u060c 10\/350 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/td>\n<td>25 kA per pole<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u062a\u0648\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649)<\/td>\n<td>~1.6\u20132.0 kV<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629<\/td>\n<td>&lt; 25 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>Follow Current Interrupt Rating<\/td>\n<td>100 A RMS<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0635\u0646\u064a\u0641 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (ISCCR)<\/td>\n<td>50 kA<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a (\u0628\u062d\u062f \u0623\u0642\u0635\u0649)<\/td>\n<td>315 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>-40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 ... +70 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td>\u0633\u0643\u0629 DIN 35 \u0645\u0645 (EN 60715)<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td>\u0628\u0644\u0627\u0633\u062a\u064a\u0643 \u062d\u0631\u0627\u0631\u064a\u060c UL94 V-0\u060c UL94 V-9<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/td>\n<td>IP20 (\u0645\u062f\u0645\u062c)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f<\/td>\n<td>\u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 RC \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/td>\n<td>IEC 61643-11 \/ EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0647\u0630\u0627 <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> is recommended for use in TN-S, TN-C, and TT systems, ensuring maximum reliability in lightning-prone areas.<\/p>\n<\/section>\n<section id=\"wiring\">\n<h3>\u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h3>\n<ul>\n<li>\u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u0648\u0635\u064a\u0644: <em>kyspd-25t1-3p-connection<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1293\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-wiring-diagram-295x300.png\" alt=\"ac surge protection device 3-pole wiring diagram\" width=\"459\" height=\"467\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-wiring-diagram-295x300.png 295w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-wiring-diagram-300x305.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-wiring-diagram.png 499w\" sizes=\"auto, (max-width: 459px) 100vw, 459px\" \/><\/li>\n<li>\u0627\u0644\u0623\u0628\u0639\u0627\u062f: <em>kyspd-25t1-3p-dimensions<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1292\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-Dimension--300x246.png\" alt=\"ac surge protection device 3-pole dimensions\" width=\"412\" height=\"338\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-Dimension--300x246.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-3P-Dimension-.png 491w\" sizes=\"auto, (max-width: 412px) 100vw, 412px\" \/><\/li>\n<\/ul>\n<\/section>\n<section id=\"apps\">\n<h3>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul>\n<li>Main distribution boards and service entrances in industrial facilities.<\/li>\n<li>First-stage <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> in coordinated SPD systems with Type 2 and Type 3 devices.<\/li>\n<li>Commercial buildings requiring reliable lightning current handling.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n<details>\n<summary>Where should KYSPD-25T1-3P be installed?<\/summary>\n<p>It should be installed at the service entrance or main distribution board as the first-stage <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong>.<\/p>\n<\/details>\n<details>\n<summary>What is the discharge current rating?<\/summary>\n<p>The device withstands Iimp 25 kA per pole, In 25 kA, and Imax 100 kA.<\/p>\n<\/details>\n<details>\n<summary>Does it support different earthing systems?<\/summary>\n<p>Yes, it is suitable for TN-S, TN-C, and TT systems.<\/p>\n<\/details>\n<details>\n<summary>Can the module be replaced?<\/summary>\n<p>Yes, the pluggable cartridge makes this <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> easy to service and maintain.<\/p>\n<\/details>\n<details>\n<summary>Is remote signaling available?<\/summary>\n<p>Yes, optional RC contacts allow integration with monitoring systems.<\/p>\n<\/details>\n<details>\n<summary>What standards does it comply with?<\/summary>\n<p>IEC\/EN 61643-11 standards for AC surge protective devices.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta\"><a href=\"\/ar\/contact-us\/\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631<\/a> - \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629: <a href=\"\/ar\/ac-mcb\/\">AC MCB<\/a>, <a href=\"\/ar\/manual-transfer-switch\/\">\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u064a\u062f\u0648\u064a<\/a><\/section>","protected":false},"excerpt":{"rendered":"<ul data-start=\"247\" data-end=\"509\">\n<li data-start=\"247\" data-end=\"343\">\n<p data-start=\"249\" data-end=\"343\">\u062b\u0644\u0627\u062b\u0629 \u0623\u0642\u0637\u0627\u0628 <strong data-start=\"260\" data-end=\"290\">\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/strong> for main distribution boards and service entrance.<\/p>\n<\/li>\n<li data-start=\"344\" data-end=\"419\">\n<p data-start=\"346\" data-end=\"419\">Impulse current Iimp 25 kA (10\/350 \u03bcs) per pole, In 25 kA, Imax 100 kA.<\/p>\n<\/li>\n<li data-start=\"420\" data-end=\"509\">\n<p data-start=\"422\" data-end=\"509\">Pluggable cartridge with status indicator; optional RC contacts; DIN-rail installation.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1584,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1291","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1291"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1584"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1291"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1291"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1291"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}